Abstract
Kalman filtering has been largely used in adaptive control for motor drive applications. However, few works relate to applications in the field of monitoring. In this paper, a fault indicator for interturn short circuits detection in permanent-magnet synchronous generators (PMSGs) is introduced. Based on the extended form of the Kalman filter and associated to an appropriate model of PMSG expressed in the $dq$ frame, this indicator has been developed through the identification of parameters specifically introduced to point out stator faults. Special attention has been paid to the indicator sensitivity and its robustness to the generator operation mode, which implies a large range of operating points. The indicator performances have been first evaluated using an appropriate simulation model. A complete experimental campaign has been performed to validate previous simulation results. A faulty PMSG, specifically built for stator fault experiments, has been associated to a digital signal processor for an online implementation of the proposed indicator. Finally, the issue of parameter uncertainties is solved by introducing a variable threshold for detection improvement.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
On the short-circuiting Fault Detection in a PMSM by means of Stator Current Transformations
Rosero, J. A., Romeral, L., Cusido, J., Garcia, A., & Ortega, J. A. (2007) · 2007 IEEE Power Electronics Specialists Conference · doi:10.1109/pesc.2007.4342300 · Cited by 63
Stator short circuits detection in PMSM by means of Hilbert-Huang transform and energy calculation
Urresty, J., Riba, J., Romeral, L., Rosero, J., & Serna, J. (2009) · 2009 IEEE International Symposium on Diagnostics for Electric Machines, Power Electronics and Drives · doi:10.1109/demped.2009.5292789 · Cited by 29
Research works printed but not linked: 29
- 10.1109/IECON.2004.1432295 · doi:10.1109/iecon.2004.1432295
- 10.1109/TIE.2013.2257142 · doi:10.1109/tie.2013.2257142
- 10.1109/IEMDC.2003.1210642 · doi:10.1109/iemdc.2003.1210642
- 10.1109/IECON.2012.6388908 · DOI
- 10.1109/TIA.2003.816531 · DOI · Paper page
- 10.1109/DEMPED.2003.1234546 · DOI
- shuting, 0, A new method of turbine-generator vibration fault diagnosis based on correlation dimension and ANN, Proc IEEE Powercon, 3, 1655
- 10.1109/IECON.2009.5414677 · DOI
- ping, 0, Fault detection of stator winding Interturn short circuit in PMSM based on wavelet packet analysis, Proc IEEE ICMTMA, 566
- 10.1109/TEC.2005.847976 · DOI · Paper page
- 10.1109/TIE.2008.2004667 · DOI · Paper page
- 10.1109/DEMPED.2011.6063609 · DOI
- 10.1109/TIE.2012.2183842 · DOI
- 10.1109/TIE.2011.2168792 · DOI · Paper page
- 10.1109/IECON.2013.6699564 · doi:10.1109/iecon.2013.6699564
- 10.1109/IEMDC.2009.5075432 · DOI
- 10.1109/DEMPED.2013.6645736 · doi:10.1109/demped.2013.6645736
- 10.1109/TEC.2005.847975 · DOI · Paper page
- 10.1109/41.873216 · DOI · Paper page
- 10.1109/TIE.2011.2160514 · DOI · Paper page
- 10.1109/IECON.2010.5674926 · DOI
- 10.1109/PES.2010.5590104 · doi:10.1109/pes.2010.5590104
- 10.1109/TIA.2013.2253081 · DOI · Paper page
- 10.1109/DEMPED.2013.6645729 · DOI
- 10.1109/TIE.2012.2229675 · DOI
- 10.1109/TIE.2006.874258 · DOI · Paper page
- 10.1109/IECON.2011.6119867 · DOI
- 10.1109/TIE.2012.2236994 · DOI · Paper page
- 10.1109/DEMPED.2009.5292797 · DOI
Cited by
Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges
Orlowska-Kowalska, T., Wolkiewicz, M., Pietrzak, P., Skowron, M., Ewert, P., Tarchala, G., Krzysztofiak, M., & Kowalski, C. T. (2022) · IEEE Access · doi:10.1109/access.2022.3180153 · Cited by 328
Choi, S., Haque, M. S., Tarek, M. T. B., Mulpuri, V., Duan, Y., Das, S., Garg, V., Ionel, D. M., Masrur, M. A., Mirafzal, B., et al. (2018) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2018.2819627 · Cited by 192
Moon, S., Jeong, H., Lee, H., & Kim, S. W. (2018) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2017.2726142 · Cited by 123
Haje Obeid, N., Battiston, A., Boileau, T., & Nahid-Mobarakeh, B. (2017) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2017.2743419 · Cited by 98
Comprehensive review on inter‐turn fault indexes in permanent magnet motors
Faiz, J., Nejadi‐Koti, H., & Valipour, Z. (2017) · IET Electric Power Applications · doi:10.1049/iet-epa.2016.0196 · Cited by 86
Metadata
- Authors
- Aubert, B., Regnier, J., Caux, S., & Alejo, D.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2015-03
- Volume
- 62
- Issue
- 3
- Pages
- 1921-1930
- ISSN
- 0278-0046 (ISSN-L)
- 1557-9948
- OpenAlex
- W2007413254
- Cited by
- 137
- References
- 2
- FWCI
- 14.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Kalman-Filter-Based Indicator for Online Interturn Short Circuits Detection in Permanent-Magnet Synchronous Generators. https://app.cochat.ai/papers/10.1109/tie.2014.2348934
- The paper
- Aubert, B., Regnier, J., Caux, S., & Alejo, D. (2015). Kalman-Filter-Based Indicator for Online Interturn Short Circuits Detection in Permanent-Magnet Synchronous Generators. IEEE Transactions on Industrial Electronics. https://doi.org/10.1109/tie.2014.2348934
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.