Short-Circuit Fault Management in DC Electric Ship Propulsion System: Protection Requirements, Review of Existing Technologies and Future Research Trends
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Ease of integration of the variable speed diesel generators resulting in substantial reduction of the fuel consumption is the key motivation for the development of the dc shipboard power system (SPS). One of the impediments to the widespread adoption of the dc SPS, however, has been the lack of comprehensive fault management strategies during the short-circuit faults. Such strategies comprise of fault detection, fault isolation, and reconfiguration of dc SPS. In the existing literature, all these aspects of fault management are dealt independently and mostly assuming ideal conditions. All the strategies are of utmost importance and it is needed to study them under a common framework which is the aim of this paper. This paper starts with a brief discussion on the characteristics of dc SPS along with recent modeling techniques. Subsequently, this paper describes the short-circuit fault studies, fault characteristics, and protection requirements. Finally, this paper outlines the working principle, advantages, and limitations of the fault detection, isolation, and reconfiguration strategies developed for the dc power system and analyzes their suitability to the dc SPS. This paper is concluded by identifying the future research trends needed for the development of the short-circuit fault management strategies of dc SPS for critical marine missions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Modular Multilevel Converter topologies with DC-Short circuit current limitation
Marquardt, R. (2011) · 8th International Conference on Power Electronics - ECCE Asia · doi:10.1109/icpe.2011.5944451 · Cited by 413
Modular Multilevel Converter DC Fault Protection
Cwikowski, O., Wickramasinghe, H. R., Konstantinou, G., Pou, J., Barnes, M., & Shuttleworth, R. (2018) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2017.2715833 · Cited by 118 · cited 1×
“Failure mode and effect analysis [50] and fault analysis have been carried out for low-voltage dc [38], [51], [52], MVDC power systems [53], and HVDC [36], [37], [54]–[56].”
BackgroundSelf-citationFault Scenarios in DC Ship Grids: The advantages and disadvantages of modular multilevel converters
Staudt, V., Bartelt, R., & Heising, C. (2015) · IEEE Electrification Magazine · doi:10.1109/mele.2015.2413436 · Cited by 22 · cited 3×
“3) Dependence on Converter Topology: The short-circuit current is dependent on the chosen converter topology [34].”
BackgroundInfluential
Cited by
Ali, Z., Terriche, Y., Hoang, L. Q. N., Abbas, S. Z., Hassan, M. A., Sadiq, M., Su, C.-L., & Guerrero, J. M. (2021) · IEEE Access · doi:10.1109/access.2021.3112383 · Cited by 104
“The authors in [45]–[48]; have summarized the protection challenges and issues in DC MGs, while the authors in [49], [50] have addressed the challenges of DC fault protection and reconfiguration issues.”
BackgroundProtection Systems for DC Shipboard Microgrids
Bayati, N., & Savaghebi, M. (2021) · Energies · doi:10.3390/en14175319 · Cited by 21
Protection Coordination for Reliable Marine DC Power Distribution Networks
Kim, S., Ulissi, G., Kim, S.-N., & Dujic, D. (2020) · IEEE Access · doi:10.1109/access.2020.3043515 · Cited by 17
Metadata
- Authors
- Satpathi, K., Ukil, A., & Pou, J.
- Venue
- IEEE Transactions on Transportation Electrification
- Published
- 2018-03
- Volume
- 4
- Issue
- 1
- Pages
- 272-291
- ISSN
- 2332-7782 (ISSN-L)
- 2372-2088
- OpenAlex
- W2778745328
- Cited by
- 137
- References
- 3
- FWCI
- 8.44
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.