The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Explosives Detection by Terahertz Spectroscopy—A Bridge Too Far?
Abstract
Terahertz spectroscopy has been investigated as a technique for concealed explosives detection since spectroscopic signatures in common explosives were first identified almost 10 years ago. This paper explores the progress towards practical development of the technology and the physical basis of the challenges involved in creating a deployable person-borne IED detection system. We conclude that, despite the theoretical potential of terahertz to provide a safe, through-barrier spectroscopic detection technique, this is unlikely to be possible in practice. The relatively weak and broad explosives features tend to be masked by the combined effects of atmospheric water vapor absorption, barrier attenuation and scattering from both clothing and the target explosives. Imaging at the lower end of the terahertz frequency range, although not offering the same specificity, is a more promising technique for security applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
THz imaging and sensing for security applications—explosives, weapons and drugs
Federici, J. F., Schulkin, B., Huang, F., Gary, D., Barat, R., Oliveira, F., & Zimdars, D. (2005) · Semiconductor Science and Technology · doi:10.1088/0268-1242/20/7/018 · Cited by 1,756
Noncovalent intermolecular forces in polycrystalline and amorphous saccharides in the far infrared
Walther, M., Fischer, B. M., & Uhd Jepsen, P. (2003) · Chemical Physics · doi:10.1016/s0301-0104(03)00031-4 · Cited by 369
Sundberg, G., Zurk, L. M., Schecklman, S., & Henry, S. (2010) · IEEE Transactions on Geoscience and Remote Sensing · doi:10.1109/tgrs.2010.2048717 · Cited by 37
Spectral artifacts from non-uniform samples analyzed by terahertz time-domain spectroscopy
Théberge, F., Châteauneuf, M., Dubois, J., Désilets, S., & Lussier, L.-S. (2009) · Optics Express · doi:10.1364/oe.17.010841 · Cited by 14
Cited by
The 2017 terahertz science and technology roadmap
Dhillon, S. S., Vitiello, M. S., Linfield, E. H., Davies, A. G., Hoffmann, M. C., Booske, J., Paoloni, C., Gensch, M., Weightman, P., Williams, G. P., et al. (2017) · Journal of Physics D: Applied Physics · doi:10.1088/1361-6463/50/4/043001 · Cited by 1,503
Review of Terahertz Tomography Techniques
Guillet, J. P., Recur, B., Frederique, L., Bousquet, B., Canioni, L., Manek-Hönninger, I., Desbarats, P., & Mounaix, P. (2014) · Journal of Infrared, Millimeter, and Terahertz Waves · doi:10.1007/s10762-014-0057-0 · Cited by 254
Metadata
- Authors
- Kemp, M. C.
- Venue
- IEEE Transactions on Terahertz Science and Technology
- Published
- 2011-09
- Volume
- 1
- Issue
- 1
- Pages
- 282-292
- ISSN
- 2156-342X (ISSN-L)
- 2156-3446
- OpenAlex
- W2146720653
- Cited by
- 187
- References
- 4
- FWCI
- 9.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Explosives Detection by Terahertz Spectroscopy—A Bridge Too Far? https://app.cochat.ai/papers/10.1109/tthz.2011.2159647
- The paper
- Kemp, M. C. (2011). Explosives Detection by Terahertz Spectroscopy—A Bridge Too Far? IEEE Transactions on Terahertz Science and Technology. https://doi.org/10.1109/tthz.2011.2159647
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.