Cited by 72Terahertz technology and applicationsMetamaterials and Metasurfaces ApplicationsMicrowave and Dielectric Measurement Techniques

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Highly Sensitive Detection of Carbendazim by Using Terahertz Time-Domain Spectroscopy Combined With Metamaterial

Qin, Binyi, Li, Zhi, Hu, Fangrong, Hu, Cong, Chen, Tao, Zhang, Huo, Zhao, Yonghong·2018·IEEE Transactions on Terahertz Science and Technology

Abstract

The rapid and sensitive detection of pesticide residue is essential for ensuring the food safety of consumers. However, there are many disadvantages for current approaches to detect pesticide residue, such as complex pre-treatment and low sensitivity. In this paper, we demonstrate a highly sensitive carbendazim detection method by using terahertz time-domain spectroscopy (THz-TDS) combined with metamaterial. The metamaterial composed of metal ohm ring arrays, is applied in detecting different concentrations of carbendazim. Resonant peaks of metamaterial move to a lower frequency as the concentration increases. The results illustrate that metamaterial can detect trace amounts of carbendazim, as small as 5 mg/L, which is about$10^4$times enhancement compared to the squash method for THz-TDS detection. It also means that metamaterial combined with THz-TDS is a potential new approach for food quality and safety control.

Overview

Integrity signals

Registry

Crossref · 10.1109/tthz.2017.2787458

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 1 references

Research works printed but not linked: 43

  1. 10.1016/0272-0590(91)90181-3 · DOI
  2. 10.1002/(SICI)1097-0185(199703)247:3<379::AID-AR9>3.0.CO;2-P · DOI
  3. 10.1063/1.4954015 · DOI
  4. 10.1109/LPT.2016.2522473 · DOI
  5. 10.1007/s11082-015-0175-5 · DOI
  6. 10.1038/srep04988 · DOI
  7. 10.1016/0040-8166(94)90041-8 · DOI
  8. 10.1007/s00429-005-0001-0 · DOI
  9. 10.1021/jf00036a021 · DOI
  10. 10.1021/acsphotonics.6b00463 · DOI
  11. 10.1002/lpor.201000011 · DOI · Paper page
  12. 10.1080/05704928.2011.614305 · DOI
  13. 10.1021/acs.jpcb.6b10248 · DOI
  14. rong, 2010, A study of vibrational spectra of L-, D-, DL-Alanine in Terahertz domain, Spectroscopy and Spectral Analysis, 30, 2023
  15. 10.1021/ac2001934 · DOI
  16. 10.1002/cphc.200600456 · DOI
  17. 10.1016/j.chemolab.2013.05.011 · DOI
  18. 10.1109/TMTT.2010.2050184 · DOI
  19. 10.4315/0362-028X.JFP-14-138 · DOI
  20. 10.1016/j.foodchem.2014.08.050 · DOI
  21. 10.1016/j.optcom.2016.11.006 · DOI
  22. 10.1016/j.foodchem.2016.09.032 · DOI
  23. 10.1016/j.chroma.2005.05.005 · DOI
  24. 10.1016/j.foodchem.2016.05.059 · DOI
  25. 10.1016/j.foodchem.2008.08.092 · DOI
  26. 10.1016/S0039-9140(01)00504-5 · DOI
  27. 10.1038/srep08671 · DOI
  28. 10.1016/j.chroma.2005.08.064 · DOI
  29. 10.1016/j.trac.2005.03.017 · DOI
  30. 10.1016/0021-9673(96)00145-8 · DOI
  31. 10.1016/j.envsci.2006.08.002 · DOI
  32. 10.1007/s00216-007-1152-z · DOI
  33. chao, 2015, Productivity effect and overuse of pesticide in crop production in China, Journal of Integrative Agriculture, 14, 1903, 10.1016/S2095-3119(15)61056-5 · DOI
  34. 10.1109/22.798002 · DOI · Paper page
  35. 10.1038/nature07247 · DOI
  36. shelby, 2001, Experimental verification of a negative index of refraction, Science, 292, 77, 10.1126/science.1058847 · DOI · Paper page
  37. 10.1364/JOSAA.18.001562 · DOI · Paper page
  38. 10.1103/PhysRevB.81.033101 · DOI
  39. 10.1126/science.1137368 · DOI
  40. 10.1016/j.bios.2012.10.095 · DOI
  41. schurig, 2006, Metamaterial electromagnetic cloak at microwave frequencies, Science, 314, 977, 10.1126/science.1133628 · DOI · Paper page
  42. 10.1364/JOSAB.27.000498 · DOI
  43. 10.1126/science.1138746 · DOI

Cited by

Sorted by citations

Metadata

Authors
Qin, B., Li, Z., Hu, F., Hu, C., Chen, T., Zhang, H., & Zhao, Y.
Affiliations
  • Xidian University (CN)
  • Guangxi Key Laboratory of Optoelectronic Information Processing (CN)
Venue
IEEE Transactions on Terahertz Science and Technology
Published
2018-03
Volume
8
Issue
2
Pages
149-154
ISSN
  • 2156-342X (ISSN-L)
  • 2156-3446
OpenAlex
W2782831726
Cited by
72
References
1
Citations by year
2026: 6 · 2025: 6 · 2024: 8 · 2023: 9 · 2022: 14 · 2021: 12 · 2020: 9 · 2019: 5 · 2018: 3
FWCI
2.77
Type
journal article
Language
en
Open access
closed
Locations
IEEE Transactions on Terahertz Science and Technology (publishedVersion)
Funders
  • Yulin Normal University Research (2016YJKY06)
  • National Natural Science Foundation of China (11574059)
  • Natural Science Foundation of Guangxi (2015GXNSFDA19039)
  • Natural Science Foundation of Guangdong (2014A030310279)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Terahertz technology and applications
  • Physical Sciences › Materials Science › Electronic, Optical and Magnetic Materials › Metamaterials and Metasurfaces Applications
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Microwave and Dielectric Measurement Techniques
Keywords
carbendazim, pesticide residue detection, terahertz time-domain spectroscopy, metamaterials, trace detection, food safety, resonant frequency shift

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review