The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
High frequency nonlinear B-scan imaging of microbubble contrast agents
Abstract
It previously was shown that it is possible to produce nonlinear scattering from microbubble contrast agents using transmit frequencies in the 14-32 MHz range, suggesting the possibility of performing high-frequency, nonlinear microbubble imaging. In this study, we describe the development of nonlinear microbubble B-scan imaging instrumentation capable of operating at transmit center frequencies between 10 and 50 MHz. The system underwent validation experiments using transmit frequencies of 20 and 30 MHz. Agent characterization experiments demonstrate the presence of nonlinear scattering for the conditions used in this study. Using wall-less vessel phantoms, nonlinear B-scan imaging is performed using energy in one of the subharmonic, ultraharmonic, and second harmonic frequency regions for transmit frequencies of 20 and 30 MHz. Both subharmonic and ultraharmonic imaging modes achieved suppression of tissue signals to below the noise floor while achieving contrast to noise ratios of up to 26 and 17 dB, respectively. The performance of second harmonic imaging was compromised by nonlinear propagation and offered no significant contrast improvement over fundamental mode imaging. In vivo experiments using the subharmonic of a 20 MHz transmit pulse show the successful detection of microvessels in the rabbit ear and in the mouse heart. The results of this study demonstrate the feasibility of nonlinear microbubble imaging at high frequencies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Scaling: Why is Animal Size so Important?
Schmidt-Nielsen, K. (1984) · doi:10.1017/cbo9781139167826 · Cited by 2,677
Cited by
Molecular ultrasound imaging: current status and future directions
Deshpande, N., Needles, A., & Willmann, J. K. (2010) · Clinical Radiology · doi:10.1016/j.crad.2010.02.013 · Cited by 306
Self-citationFan, C.-H., Liu, H.-L., Ting, C.-Y., Lee, Y.-H., Huang, C.-Y., Ma, Y.-J., Wei, K.-C., Yen, T.-C., & Yeh, C.-K. (2014) · PLoS ONE · doi:10.1371/journal.pone.0096327 · Cited by 84
Metadata
- Authors
- Goertz, D. E., Cherin, E., Needles, A., Karshafian, R., Brown, A. S., Burns, P. N., & Foster, F. S.
- Venue
- IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control
- Published
- 2005-01
- Volume
- 52
- Issue
- 1
- Pages
- 65-79
- ISSN
- 0885-3010 (ISSN-L)
- OpenAlex
- W2118333878
- Cited by
- 175
- References
- 1
- FWCI
- 13.01
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: High frequency nonlinear B-scan imaging of microbubble contrast agents. https://app.cochat.ai/papers/10.1109/tuffc.2005.1397351
- The paper
- Goertz, D. E., Cherin, E., Needles, A., Karshafian, R., Brown, A. S., Burns, P. N., & Foster, F. S. (2005). High frequency nonlinear B-scan imaging of microbubble contrast agents. IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control. https://doi.org/10.1109/tuffc.2005.1397351
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.