Planar-waveguide external cavity laser stabilization for an optical link with 10-19 frequency stability
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
We stabilized the frequency of a compact planar-waveguide external cavity laser (ECL) on a Fabry-Perot cavity (FPC) through a Pound-Drever-Hall scheme. The residual frequency stability of the ECL is 10(-14), comparable to the stability achievable with a fiber laser (FL) locked to an FPC through the same scheme. We set up an optical link of 100 km, based on fiber spools, that reaches 10(-19) relative stability, and we show that its performances using the ECL or FL are comparable. Thus ECLs could serve as an excellent replacement for FLs in optical links where cost-effectiveness and robustness are important considerations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Frequency Ratio of Al+and Hg+Single-Ion Optical Clocks; Metrology at the 17th Decimal Place
Rosenband, T., Hume, D. B., Schmidt, P. O., Chou, C. W., Brusch, A., Lorini, L., Oskay, W. H., Drullinger, R. E., Fortier, T. M., Stalnaker, J. E., et al. (2008) · Science · doi:10.1126/science.1154622 · Cited by 1,450 · cited 1×
“They allow excitation of ultra-narrow atomic transitions in high-resolution spectroscopy and in optical atomic clocks [1], [2].”
BackgroundMa, L.-S., Jungner, P., Ye, J., & Hall, J. L. (1994) · Optics Letters · doi:10.1364/ol.19.001777 · Cited by 566
Cited by
High-accuracy coherent optical frequency transfer over a doubled 642-km fiber link
Calonico, D., Bertacco, E. K., Calosso, C. E., Clivati, C., Costanzo, G. A., Frittelli, M., Godone, A., Mura, A., Poli, N., Sutyrin, D. V., et al. (2014) · Applied Physics B · doi:10.1007/s00340-014-5917-8 · Cited by 168
Self-citationFrequency transfer via a two-way optical phase comparison on a multiplexed fiber network
Calosso, C. E., Bertacco, E., Calonico, D., Clivati, C., Costanzo, G. A., Frittelli, M., Levi, F., Mura, A., & Godone, A. (2014) · Optics Letters · doi:10.1364/ol.39.001177 · Cited by 85
Self-citationDoppler-stabilized fiber link with 6 dB noise improvement below the classical limit
Calosso, C. E., Bertacco, E. K., Calonico, D., Clivati, C., Costanzo, G. A., Frittelli, M., Levi, F., Micalizio, S., Mura, A., & Godone, A. (2015) · Optics Letters · doi:10.1364/ol.40.000131 · Cited by 23
Self-citationBarbieri, P., Clivati, C., Pizzocaro, M., Levi, F., & Calonico, D. (2019) · Metrologia · doi:10.1088/1681-7575/ab2b0f · Cited by 18
Self-citation
Metadata
- Authors
- Clivati, C., Mura, A., Calonico, D., Levi, F., Costanzo, G. A., Calosso, C. E., & Godone, A.
- Venue
- IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Published
- 2011-12
- Volume
- 58
- Issue
- 12
- Pages
- 2582-2587
- ISSN
- 0885-3010 (ISSN-L)
- OpenAlex
- W2166702241
- Cited by
- 48
- References
- 2
- FWCI
- 4.34
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Planar-waveguide external cavity laser stabilization for an optical link with 10-19 frequency stability. https://app.cochat.ai/papers/10.1109/tuffc.2011.2121
- The paper
- Clivati, C., Mura, A., Calonico, D., Levi, F., Costanzo, G. A., Calosso, C. E., & Godone, A. (2011). Planar-waveguide external cavity laser stabilization for an optical link with 10-19 frequency stability. IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control. https://doi.org/10.1109/tuffc.2011.2121
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.