CoChat

Dependence of the reversibility of focused- ultrasound-induced blood-brain barrier opening on pressure and pulse length in vivo

Open access
Samiotaki, Gesthimani, Konofagou, Elisa E. · 2013 · IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Cited by 103

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

The most challenging aspect of intravenously-administered drugs currently developed to treat central nervous system (CNS) diseases is their impermeability through the blood-brain barrier (BBB), a specialized vasculature system protecting the brain microenvironment. Focused ultrasound (FUS) in conjunction with systemically administered microbubbles has been shown to open the BBB locally, noninvasively, and reversibly. The objective of this study was to investigate the effect of FUS (center frequency: 1.5 MHz) pulse length (PL), ranging here from 67 μs to 6.7 ms, on the physiology of the FUS-induced BBB opening. Dynamic contrast-enhanced (DCE) and T1-weighted magnetic resonance imaging (MRI) were used to quantify the permeability changes using transfer rate (Ktrans) mapping, the volume of BBB opening (VBBB) and the reversibility timeline of the FUS-induced BBB opening, with the systemic administration of microbubbles at different acoustic pressures, ranging from 0.30 to 0.60 MPa. Permeability and volume of opening were both found to increase with the acoustic pressure and pulse length. At 67-μs PL, the opening pressure threshold was 0.45 MPa, with BBB opening characteristics similar to those induced with 0.60 MPa at the same PL, as well as with 0.67-ms PL/0.30 MPa. On average, these cases had Ktrans = 0.0049 ± 0.0014 min-1 and VBBB = 3.7 ± 4.3 mm(3), and closing occurred within 8 h. The 6.7-ms PL/0.30 MPa induced similar opening with 0.67-ms PL/0.45 MPa, and a closing timeline of 24 to 48 h. On average, Ktrans was 0.0091 ± 0.0029 min-1 and VBBB was 14.13 ± 7.7 mm(3) in these cases. Also, there were no significant differences between the 6.7-ms PL/0.45 MPa, 0.67-ms PL/0.60 MPa and 6.7-ms PL/0.60 MPa cases, yielding on average a Ktrans of 0.0100 ± 0.0023 min-1 and VBBB equal to 20.1 ± 5.7 mm(3). Closing occurred within 48 to 72 h in these cases. Stacked histograms of the Ktrans provided further insight to the nonuniform spatial distribution of permeability changes and revealed a correlation with the closing timeline. These results also suggest a beneficial complementary relationship between the elongation of the PL and the decrease of the peak negative acoustic pressures, and vice versa. Linear regression between Ktrans and VBBB showed a good correlation fit. Also, the time required for closing linearly increased with VBBB. The volume rate of decrease was measured to be 11.4 ± 4.0 mm3 per day, suggesting that the closing timeline could be predicted from the initial volume of opening. Finally, no histological damage was detected in any of the cases 7 d post-FUS, indicating the safety of the methodology and parameters used.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tuffc.2013.6644731

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

Metadata

Authors
Samiotaki, G., & Konofagou, E. E.
Venue
IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Published
2013-11
Volume
60
Issue
11
Pages
2257-2265
ISSN
0885-3010 (ISSN-L)
OpenAlex
W2161323379
Cited by
103
References
3
FWCI
3.37
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.