Cited by 176Ultrasonics and Acoustic Wave PropagationUltrasound Imaging and ElastographyRadio Frequency Integrated Circuit Design

Single-chip CMUT-on-CMOS front-end system for real-time volumetric IVUS and ICE imaging

Open access
Gurun, Gokce, Tekes, Coskun, Zahorian, Jaime, Xu, Toby, Satir, Sarp, Karaman, Mustafa, Hasler, Jennifer, Degertekin, F. Levent·2014·IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control

Abstract

Intravascular ultrasound (IVUS) and intracardiac echography (ICE) catheters with real-time volumetric ultrasound imaging capability can provide unique benefits to many interventional procedures used in the diagnosis and treatment of coronary and structural heart diseases. Integration of capacitive micromachined ultrasonic transducer (CMUT) arrays with front-end electronics in single-chip configuration allows for implementation of such catheter probes with reduced interconnect complexity, miniaturization, and high mechanical flexibility. We implemented a single-chip forward-looking (FL) ultrasound imaging system by fabricating a 1.4-mm-diameter dual-ring CMUT array using CMUT-on-CMOS technology on a front-end IC implemented in 0.35-μm CMOS process. The dual-ring array has 56 transmit elements and 48 receive elements on two separate concentric annular rings. The IC incorporates a 25-V pulser for each transmitter and a low-noise capacitive transimpedance amplifier (TIA) for each receiver, along with digital control and smart power management. The final shape of the silicon chip is a 1.5-mm-diameter donut with a 430-μm center hole for a guide wire. The overall front-end system requires only 13 external connections and provides 4 parallel RF outputs while consuming an average power of 20 mW. We measured RF A-scans from the integrated single- chip array which show full functionality at 20.1 MHz with 43% fractional bandwidth. We also tested and demonstrated the image quality of the system on a wire phantom and an ex vivo chicken heart sample. The measured axial and lateral point resolutions are 92 μm and 251 μm, respectively. We successfully acquired volumetric imaging data from the ex vivo chicken heart at 60 frames per second without any signal averaging. These demonstrative results indicate that single-chip CMUT-on-CMOS systems have the potential to produce realtime volumetric images with image quality and speed suitable for catheter-based clinical applications.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tuffc.2014.6722610

Cites

44 of 44 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Efforts have been reported to integrate LEDs for optogenetic stimulation and receiving elements for wireless power transfer on chip for mm-scale devices.

    “Other common off-chip components include light emitting diodes (LEDs) for optogenetic stimulation, and receiving elements for wireless power transfer, such as inductors, antennas, ultrasonic transducers. Efforts have been reported to integrate all of these on chip for mm-scale devices (Zargham and Glenn Gulak 2015; Gurun et al. 2014).”

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Research works printed but not linked: 1

  1. [28]Salvia J Lajevardi P Hekmat M Murmann B A 56M Omega CMOS TIA for MEMS Applications Proceedings of the IEEE 2009 Custom Integrated Circuits Conference 2009 199 202

Cited by

Sorted by citations

Authors
Gurun, G., Tekes, C., Zahorian, J., Xu, T., Satir, S., Karaman, M., Hasler, J., & Degertekin, F. L.
Affiliations
  • Georgia Institute of Technology (US)
  • Istanbul Technical University (TR)
Venue
IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Published
2014-02
Volume
61
Issue
2
Pages
239-250
ISSN
0885-3010 (ISSN-L)
OpenAlex
W2161817031
Cited by
176
References
44
Citations by year
2026: 1 · 2025: 8 · 2024: 16 · 2023: 9 · 2022: 14 · 2021: 23 · 2020: 15 · 2019: 15 · 2018: 23 · 2017: 20 · 2016: 14 · 2015: 9 · 2014: 9
FWCI
17.96
Type
journal article
Language
en
Open access
Locations
  • IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control (publishedVersion)
  • PubMed (publishedVersion)
  • PubMed Central (acceptedVersion)
  • Istanbul Technical University Academic Open Archive (Istanbul Technical University) (submittedVersion)
Funders
  • Georgia Institute of Technology
  • National Institute of Biomedical Imaging and Bioengineering (R01EB010070)
Topics
  • Physical Sciences › Engineering › Mechanics of Materials › Ultrasonics and Acoustic Wave Propagation
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Ultrasound Imaging and Elastography
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Radio Frequency Integrated Circuit Design
Keywords
capacitive micromachined ultrasonic transducers, intravascular ultrasound, intracardiac echocardiography, volumetric ultrasound imaging, capacitive transimpedance amplifier, pulser, power management, catheter-based imaging, real-time imaging, point resolution
MeSH terms
Amplifiers, Electronic, Animals, Chickens, Computer Systems, Echocardiography, Equipment Design, Sensitivity and Specificity, Signal Processing, Computer-Assisted, Transducers, Reproducibility of Results, Ultrasonography, Interventional, Phantoms, Imaging, Equipment Failure Analysis, Imaging, Three-Dimensional, Electric Capacitance

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review