Cited by 15Ultrasonics and Acoustic Wave PropagationUltrasound and Hyperthermia ApplicationsNeuroscience and Neural Engineering

S-MRUT: sectored-multiring ultrasonic transducer for selective powering of brain implants

Open access
Hosseini, Seyedsina, Laursen, Kjeld, Rashidi, Amin, Mondal, Tanmay, Corbett, Brian, Moradi, Farshad·2021·IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control

Abstract

One of the main challenges of the current ultrasonic transducers for powering brain implants is the complexity of focusing ultrasonic waves in various axial and lateral directions. The available transducers usually use electrically controlled phased array for beamforming the ultrasonic waves, which increases the complexity of the system even further. In this article, we propose a straightforward solution for selective powering of brain implants to remove the complexity of conventional phased arrays. Our approach features a Sectored-Multiring Ultrasonic Transducer (S-MRUT) on a single piezoelectric sheet, specifically designed for powering implantable devices for optogenetics in freely moving animals. The proposed unidirectional S-MRUT is capable of focusing the ultrasonic waves on brain implants located at different depths and regions of the brain. The S-MRUT is designed based on Fresnel Zone Plate (FZP) theory, simulated in COMSOL, and fabricated with the microfabrication process. The acoustic profile of the seven different configurations of the S-MRUT was measured using a hydrophone with the total number of 7436 grid points. The measurements show the ability of the proposed S-MRUT to sweep the focus point of the acoustic waves in the axial direction in depths of 1 - 3 mm, which is suitable for powering implants in the striatum of the mouse. Furthermore, the proposed S-MRUT demonstrates a steering area with an average radius of 0.862 mm and 0.678mm in experiments and simulations, respectively. The S-MRUT is designed with the size of 3.8 × 3.8 × 0.5 mm3and the weight of 0.054gr, showing that it is compact and light enough to be worn by a mouse. Finally, the S-MRUT was tested in our measurement setup, where it successfully transfers sufficient power to a 2.8-mm3optogentic stimulator to turn on a micro-LED on the stimulator.

Integrity signals

Registry

Crossref · 10.1109/tuffc.2020.3001084

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • The Sectored-Multiring Ultrasonic Transducer (S-MRUT), built on a single piezoelectric sheet, can focus ultrasonic waves on implants at various depths without the complexity of phased arrays.

    “A study introduced the Sectored-Multiring Ultrasonic Transducer (S-MRUT), built on a single piezoelectric sheet, capable of focusing ultrasonic waves on implants at various depths without the complexity of phased arrays (Hosseini et al., 2021).”

    From Comparative analysis of energy transfer mechanisms for neural implants (2024) · cites this paper as Hosseini et al., 2021

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Hosseini, S., Laursen, K., Rashidi, A., Mondal, T., Corbett, B., & Moradi, F.
Affiliations
  • Aarhus University (DK)
  • University College Cork (IE)
Venue
IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Published
2021-01
Volume
68
Issue
1
Pages
191-200
ISSN
  • 0885-3010 (ISSN-L)
  • 1525-8955
OpenAlex
W3034924965
Cited by
15
References
2
Citations by year
2026: 2 · 2024: 5 · 2023: 3 · 2022: 2 · 2021: 3
FWCI
1.02
Type
journal article
Language
en
Open access
Locations
  • IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control (publishedVersion)
  • PubMed (publishedVersion)
  • Cork Open Research Archive (University College Cork, Ireland) (submittedVersion)
  • Arrow@dit (Dublin Institute of Technology) (submittedVersion)
  • Scopus (Elsevier) (submittedVersion)
Funders
European Union’s Horizon 2020 Research and Innovation Program through the project STARDUST (767092)
Topics
  • Physical Sciences › Engineering › Mechanics of Materials › Ultrasonics and Acoustic Wave Propagation
  • Physical Sciences › Engineering › Biomedical Engineering › Ultrasound and Hyperthermia Applications
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
Keywords
ultrasonic transducers, neural implants, optogenetics, Fresnel zone plate, acoustic focusing, striatum, microfabrication
MeSH terms
Animals, Brain, Equipment Design, Transducers, Ultrasonics, Prostheses and Implants, Mice

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review