Highly-scalable novel access device based on Mixed Ionic Electronic conduction (MIEC) materials for high density phase change memory (PCM) arrays
The DOI matches its Crossref record.
Abstract
Phase change memory (PCM) could potentially achieve high density with large, 3Dstacked crosspoint arrays, but not without a BEOL-friendly access device (AD) that can provide high current densities and large ON/OFF ratios. We demonstrate a novel AD based on Cu-ion motion in novel Cu-containing Mixed Ionic Electronic Conduction (MIEC) materials[1, 2]. Experimental results on various device structures show that these ADs provide the ultra-high current densities needed for PCM, exhibit high ON/OFF ratios with excellent uniformity, are highly scalable, and are compatible with <;400°C Back-End-Of-the-Line (BEOL) fabrication.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Wong, H.-S. P., Lee, H.-Y., Yu, S., Chen, Y.-S., Wu, Y., Chen, P.-S., Lee, B., Chen, F. T., & Tsai, M.-J. (2012) · Proceedings of the IEEE · doi:10.1109/jproc.2012.2190369 · Cited by 2,757
Emerging Memory Technologies: Recent Trends and Prospects
Yu, S., & Chen, P.-Y. (2016) · IEEE Solid-State Circuits Magazine · doi:10.1109/mssc.2016.2546199 · Cited by 555
The Future of Memristors: Materials Engineering and Neural Networks
Sun, K., Chen, J., & Yan, X. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202006773 · Cited by 482
Access devices for 3D crosspoint memory
Burr, G. W., Shenoy, R. S., Virwani, K., Narayanan, P., Padilla, A., Kurdi, B., & Hwang, H. (2014) · Journal of Vacuum Science & Technology B, Nanotechnology and Microelectronics: Materials, Processing, Measurement, and Phenomena · doi:10.1116/1.4889999 · Cited by 371
Self-citationCrossbar RRAM Arrays: Selector Device Requirements During Read Operation
Zhou, J., Kim, K.-H., & Lu, W. (2014) · IEEE Transactions on Electron Devices · doi:10.1109/ted.2014.2310200 · Cited by 310
ReRAM: History, Status, and Future
Chen, Y. (2020) · IEEE Transactions on Electron Devices · doi:10.1109/ted.2019.2961505 · Cited by 294
Crossbar RRAM Arrays: Selector Device Requirements During Write Operation
Kim, S., Zhou, J., & Lu, W. D. (2014) · IEEE Transactions on Electron Devices · doi:10.1109/ted.2014.2327514 · Cited by 219
RRAM Crossbar Array With Cell Selection Device: A Device and Circuit Interaction Study
Deng, Y., Huang, P., Chen, B., Yang, X., Gao, B., Wang, J., Zeng, L., Du, G., Kang, J., & Liu, X. (2013) · IEEE Transactions on Electron Devices · doi:10.1109/ted.2012.2231683 · Cited by 184
Chakraborty, I., Ali, M., Ankit, A., Jain, S., Roy, S., Sridharan, S., Agrawal, A., Raghunathan, A., & Roy, K. (2020) · Proceedings of the IEEE · doi:10.1109/jproc.2020.3003007 · Cited by 140
“V characteristics that can be adopted in 1S-1R crossbars [80].”
BackgroundImproved Synaptic Behavior of CBRAM Using Internal Voltage Divider for Neuromorphic Systems
Lim, S., Kwak, M., & Hwang, H. (2018) · IEEE Transactions on Electron Devices · doi:10.1109/ted.2018.2857494 · Cited by 40
“leads to the change in the resistivity because the vacancy site of Cu acts as an acceptor [25]–[27].”
Background
Metadata
- Authors
- Gopalakrishnan, K., Shenoy, R. S., Rettner, C. T., Virwani, K., Bethune, D. S., Shelby, R. M., Burr, G. W., Kellock, A., King, R. S., Nguyen, K., Bowers, A. N., Jurich, M., Jackson, B., Friz, A. M., Topuria, T., Rice, P. M., & Kurdi, B. N.
- Venue
- 2010 Symposium on VLSI Technology
- Publisher
- IEEE
- Published
- 2010-06
- Pages
- 205-206
- OpenAlex
- W2152106591
- Cited by
- 126
- References
- 0
- FWCI
- 30.91
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.