Back-EMF Based Detection of Stator Winding Inter-turn Fault for PM Synchronous Motor Drives
The DOI matches its Crossref record.
Abstract
In this paper, a new technique for stator winding inter-turn fault detection in Permanent Magnet Synchronous Machines is proposed. It consists of extracting the mechanical power second harmonic component which appears when the machine is faulty. This harmonic is processed in order to obtain a fault indicator. It will be shown that the amplitude of this indicator depends on the inter-turn fault severity. The proposed technique allows detecting the fault in real time and its implementation is easy. The experimental results show the validity of the proposed method.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 10
- 10.1109/IAS.2004.1348827 · doi:10.1109/ias.2004.1348827
- 10.1109/41.873216 · DOI · Paper page
- 10.1109/TIA.2006.889826 · DOI · Paper page
- 10.1109/EPEPEMC.2006.283305 · doi:10.1109/epepemc.2006.283305
- 10.1109/IECON.2006.348093 · doi:10.1109/iecon.2006.348093
- rangarajan, 2002, Transient Model for Induction Machines With Stator Winding Turn Faults, IEEE Trans on Ind Appl, 38
- arkan, 2001, Online stator fault diagnosis in induction motors Electric Power Applications, IEE Proceedings, 148, 537
- 10.1109/TIA.2002.802935 · DOI · Paper page
- 10.1109/28.952496 · DOI · Paper page
- 10.1109/IEMDC.2003.1211236 · doi:10.1109/iemdc.2003.1211236
Cited by
Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges
Orlowska-Kowalska, T., Wolkiewicz, M., Pietrzak, P., Skowron, M., Ewert, P., Tarchala, G., Krzysztofiak, M., & Kowalski, C. T. (2022) · IEEE Access · doi:10.1109/access.2022.3180153 · Cited by 328
“In [58] the second harmonic of active and reactive power spectrum is proposed as the FI independent on the motor control type.”
BackgroundMitigation of Turn-to-Turn Faults in Fault Tolerant Permanent Magnet Synchronous Motors
Cintron-Rivera, J. G., Foster, S. N., & Strangas, E. G. (2015) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2014.2360813 · Cited by 104
“A winding fault creates an unbalanced operating condition, from which measurable information such as the voltages [19], [20], sequence components [21], impedance changes [22] and harmonic content [12] could be used for detection purposes.”
Real-Time Detection of Interturn Faults in PM Drives Using Back-EMF Estimation and Residual Analysis
Leboeuf, N., Boileau, T., Nahid-Mobarakeh, B., Clerc, G., & Meibody-Tabar, F. (2011) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2011.2168929 · Cited by 92
Self-citationSynchronous Demodulation of Control Voltages for Stator Interturn Fault Detection in PMSM
Boileau, T., Leboeuf, N., Nahid-Mobarakeh, B., & Meibody-Tabar, F. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2254132 · Cited by 90
Self-citationFault-Tolerant Control of PMSM With Inter-Turn Short-Circuit Fault
Zhang, J., Zhan, W., & Ehsani, M. (2019) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2019.2936225 · Cited by 64
A review of Permanent Magnet Synchronous Motor fault diagnosis
ZhifuWang, Yang, J., Ye, H., & Zhou, W. (2014) · 2014 IEEE Conference and Expo Transportation Electrification Asia-Pacific (ITEC Asia-Pacific) · doi:10.1109/itec-ap.2014.6940870 · Cited by 62
Metadata
- Authors
- Boileau, T., Nahid-Mobarakeh, B., & Meibody-Tabar, F.
- Venue
- 2007 IEEE Vehicle Power and Propulsion Conference
- Publisher
- IEEE
- Published
- 2007-09
- Pages
- 95-100
- OpenAlex
- W2010727011
- Cited by
- 35
- References
- 0
- FWCI
- 2.29
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.