Health monitoring, fault diagnosis and failure prognosis techniques for Brushless Permanent Magnet Machines
The DOI matches its Crossref record; 59 of the 62 references it cites were found in a registry or an index.
Abstract
Over the past few years, many researchers have been attracted by the challenges of electrical machines' fault diagnosis and condition monitoring, which provide early warnings that could help schedule necessary maintenance to avoid catastrophic consequence. With advancements in the use of rare-earth magnets, Brushless Permanent Magnet Machines are widely used in industry recently, which has led to the development of numerous fault diagnosis techniques. Considerable papers have presented reviews and compared condition monitoring and fault diagnosis methods for induction machines, but none for Brushless Permanent Magnet Machines. To make a difference, this paper presents a comprehensive survey of modern research advancements and state-of-the-art in health monitoring, fault diagnosis and prognosis techniques for Brushless Permanent Magnet Machines. The symptoms of each type of fault and the principles of diagnosis process are also described and discussed.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“To the best authors' knowledge the first review on diagnostics of PM machines (BLDC and PMSM) was published in 2011 [14].”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [14]
Citations
Cites
Condition Monitoring and Fault Diagnosis of Electrical Motors—A Review
Nandi, S., Toliyat, H. A., & Li, X. (2005) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2005.847955 · Cited by 2,382 · cited 2×
“Considerable papers have presented reviews and compared condition monitoring and fault diagnosis methods for induction machines [1]-[4], but none for Brushless Permanent Magnet Machines.”
A review of induction motors signature analysis as a medium for faults detection
El Hachemi Benbouzid, M. (2000) · IEEE Transactions on Industrial Electronics · doi:10.1109/41.873206 · Cited by 1,602
Electric Motor Drivers: Modeling, Analysis, and Control
Krishnan, R. (2001) · Cited by 1,561
Introduction to magnetism and magnetic materials
(2016) · Choice Reviews Online · doi:10.5860/choice.195889 · Cited by 1,518
Neural-network-based motor rolling bearing fault diagnosis
Li, B., Chow, M.-Y., Tipsuwan, Y., & Hung, J. C. (2000) · IEEE Transactions on Industrial Electronics · doi:10.1109/41.873214 · Cited by 797
Parameter Estimation, Condition Monitoring, and Diagnosis of Electrical Machines
Vas, P. (1992) · doi:10.1093/oso/9780198593751.001.0001 · Cited by 711
Report of Large Motor Reliability Survey of Industrial and Commercial Installations, Part I
(1985) · IEEE Transactions on Industry Applications · doi:10.1109/tia.1985.349532 · Cited by 602
Zhu, Z. Q., Howe, D., & Chan, C. C. (2002) · IEEE Transactions on Magnetics · doi:10.1109/20.990112 · Cited by 492 · cited 1×
“Zhu et al. [ 16 ] reported a 2D analytical method to predict magnetic flux density of PMSM under different scenarios.”
MethodStatic-, Dynamic-, and Mixed-Eccentricity Fault Diagnoses in Permanent-Magnet Synchronous Motors
Ebrahimi, B. M., Faiz, J., & Roshtkhari, M. J. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2029577 · Cited by 386 · cited 1×
“Static eccentricity ratio is defined as [15]”
Basic vibration signal processing for bearing fault detection
McInerny, S. A., & Dai, Y. (2003) · IEEE Transactions on Education · doi:10.1109/te.2002.808234 · Cited by 321 · cited 1×
“It could be caused by 1) Metal fatigue 2) Unbalanced stress 3) Improper installation 4) Corrosion/Contamination These problems could result in vibrations and noise during machine operation, which are usually measured and processed as diagnosis indicators [12].”
Cited by
Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges
Orlowska-Kowalska, T., Wolkiewicz, M., Pietrzak, P., Skowron, M., Ewert, P., Tarchala, G., Krzysztofiak, M., & Kowalski, C. T. (2022) · IEEE Access · doi:10.1109/access.2022.3180153 · Cited by 328
“Damage to the insulation results from abrasion caused by mechanical stress or overheating of the winding as a result of excessive loads on the motor [14]-[20], [23], [26], [27].”
BackgroundMethodInfluentialAn Effective Stator Fault Diagnosis Framework of BLDC Motor Based on Vibration and Current Signals
Shifat, T. A., & Hur, J.-W. (2020) · IEEE Access · doi:10.1109/access.2020.3000856 · Cited by 125
“A detailed survey of BLDC motors faults can be found in [14].”
BackgroundMoosavi, S. S., Djerdir, A., Amirat, Y. A., & Khaburi, D. A. (2015) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2015.04.062 · Cited by 96
Yang, Z., Shi, X., & Krishnamurthy, M. (2014) · 2014 IEEE Transportation Electrification Conference and Expo (ITEC) · doi:10.1109/itec.2014.6861774 · Cited by 72
“INTRODUCTION Vibration monitoring [1-6] as a non-intrusive approach, is extensively used for electric fault diagnosis of PMSM.”
BackgroundSelf-citationZhang, J., Xu, Z., Wang, J., Zhao, J., Din, Z., & Cheng, M. (2020) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2020.3009563 · Cited by 75
“The investigation shows that about 37% of all possible failures of the PMSM occur in the stator [2].”
BackgroundA Voltage-Based Approach for Fault Detection and Separation in Permanent Magnet Synchronous Machines
Haddad, R. Z., Lopez, C. A., Foster, S. N., & Strangas, E. G. (2017) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2017.2726072 · Cited by 65
“different faults [7].”
Methods of Condition Monitoring and Fault Detection for Electrical Machines
Kudelina, K., Asad, B., Vaimann, T., Rassõlkin, A., Kallaste, A., & Khang, H. V. (2021) · Energies · doi:10.3390/en14227459 · Cited by 65
“The most frequent permanent magnet fault is demagnetization, which means partial or complete magnetization loss [60].”
BackgroundYassa, N., & Rachek, M. (2018) · Mathematics and Computers in Simulation · doi:10.1016/j.matcom.2018.04.012 · Cited by 53
Fault Diagnosis of Brushless DC Motors Using Built-In Hall Sensors
Zandi, O., & Poshtan, J. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2917847 · Cited by 53
“In small motors with low level vibrations, accelerometers are not normally used due to their high costs [10].”
BackgroundEEMD assisted supervised learning for the fault diagnosis of BLDC motor using vibration signal
Shifat, T. A., & Hur, J.-W. (2020) · Journal of Mechanical Science and Technology · doi:10.1007/s12206-020-2208-7 · Cited by 46
Shifat, T. A., & Hur, J.-W. (2020) · IEEE Access · doi:10.1109/access.2020.3023335 · Cited by 53
“A detailed survey of BLDC motors faults can be found in [13].”
BackgroundMain Faults and Diagnostic Possibilities of BLDC Motors
Kudelina, K., Asad, B., Vaimann, T., Rassõlkin, A., Kallaste, A., & Lukichev, D. V. (2020) · International Workshop on Electric Drives (IWED) · doi:10.1109/iwed48848.2020.9069553 · Cited by 40
“The bearing failure can be indicated by increased noise and vibration[16].”
BackgroundInfluentialZhang, J., Salman, M. A., Zanardelli, W. G., Ballal, S., & Cao, B. (2020) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2020.3025107 · Cited by 39
“[29] considered failure prognosis for multiple faults in PMSM drives, including stator, rotor magnets, and mechanical faults.”
BackgroundReview of Methods for Diagnosing Faults in the Stators of BLDC Motors
Solís, R., Torres, L., & Pérez‐Alcázar, P. R. (2022) · Processes · doi:10.3390/pr11010082 · Cited by 44
Said, H., Nicoletti, T., & Perez-Hernandez, P. (2014) · Journal of Computing in Civil Engineering · doi:10.1061/(asce)cp.1943-5487.0000444 · Cited by 26
“Previous research on equipment and machine health monitory focused on monitoring the condition (primarily the vibrations) of stationary mechanical machines or electrical micro-machines (Dutta and Giurgiutiu 2000; Yan and Gao 2007; Da et al. 2011).”
BackgroundFeature extraction for vibration-based fault detection in Permanent Magnet Synchronous Motors
Alameh, K., Cité, N., Hoblos, G., & Barakat, G. (2015) · International Conference on Technological Advances in Electrical, Electronics and Computer Engineering · doi:10.1109/taeece.2015.7113620 · Cited by 24
“[16] Y.”
BackgroundA Review of Robotic Arm Joint Motors and Online Health Monitoring Techniques
Metwly, M. Y., Clark, C. L., He, J., & Xie, B. (2024) · IEEE Access · doi:10.1109/access.2024.3447573 · Cited by 29
Demagnetization fault investigation in permanent magnet synchronous motor
Moosavi, S. S., Djerdir, A., Amirat, Y. A., & Khaburi, D. A. (2014) · Power Electronics, Drive Systems, and Technologies Conference (PEDSTC) · doi:10.1109/pedstc.2014.6799448 · Cited by 23
“Some of the most common advantages of PMAC motors over other electric motors available on the market include [1-4]: High dynamic response performance, Higher efficiency because of fewer losses (High efficiency providing reduction in machine size covering Low volume and thickness and lead to low weight, Low acoustic no…”
BackgroundRen, Y., Yi, R., Lian, Z., Xia, Q., Yang, D., Sun, B., & Feng, Q. (2024) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2024.110402 · Cited by 18
Implementation of PMSM Inter-turn Short Fault Detection Using Frequency Analysis of Stator Currents
Otava, L. (2016) · IFAC-PapersOnLine · doi:10.1016/j.ifacol.2016.12.015 · Cited by 17
Permanent magnet synchronous motor stator winding fault detection
Otava, L., & Buchta, L. (2016) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2016.7793941 · Cited by 16
“A stator winding faults are the most frequent electrical faults in PMSM drives [1].”
BackgroundFrequency Energy Analysis in Detecting Rolling Bearing Faults
Wescoat, E., Mears, L., Goodnough, J., & Sims, J. (2020) · Procedia Manufacturing · doi:10.1016/j.promfg.2020.05.137 · Cited by 17
Impact of Bearing Faults on Vibration Level of BLDC Motor
Kudelina, K., Vaimann, T., Rassõlkin, A., & Kallaste, A. (2021) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon48115.2021.9589268 · Cited by 15
Schlesinger, L., Koller, J., Oechsle, O., & Molenda, P. (2021) · International Electric Drives Production Conference · doi:10.1109/edpc53547.2021.9684200 · Cited by 15
Unitary Anomaly Detection for Ubiquitous Safety in Machine Health Monitoring
Amar, M., Gondal, I., & Wilson, C. (2012) · Lecture notes in computer science · doi:10.1007/978-3-642-34500-5_43 · Cited by 12
Self-Commissioning Parameter Estimation Algorithm for Loaded Induction Motors
Travieso‐Torres, J. C., Lee, S. S., Véliz-Tejo, A., Leiva-Silva, F., & Ricaldi-Morales, A. (2024) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2024.3357900 · Cited by 12
“The knowledge of IMs and their load parameters is necessary to detect abnormal operation conditions [2], [3], in energy saving planning [4], observing state variables[5],[6],andtocontrolthem[7],[8].”
BackgroundAnalysis of Shaft Voltage in Rotor Permanent Magnet Synchronous Motor System for Traction
Duan, M., Ou, Z., & Deng, C. (2020) · IEEE Conference on Industrial Electronics and Applications (ICIEA) · doi:10.1109/iciea48937.2020.9248127 · Cited by 11
“1[3].”
Raja, H. A., Raval, H., Vaimann, T., Kallaste, A., Rassõlkin, A., & Belahcen, A. (2022) · International Conference on Diagnostics in Electrical Engineering (Diagnostika) · doi:10.1109/diagnostika55131.2022.9905102 · Cited by 14
Throughput Estimation of K-zone Gbps Radio Links Operating in the E-band
Ambrozic, V., Breznik, M., & Nemec, M. (2022) · Informacije MIDEM - Journal of Microelectronics Electronic Components and Materials · doi:10.33180/infmidem2022.103 · Cited by 12
Methodology to study demagnetization risk in permanent magnet machines by Finite Element Method
Gómez, I., Almandoz, G., Ugalde, G., Poza, J., & Escalada, A. J. (2017) · IEEE Workshop on Electrical Machines Design, Control and Diagnosis · doi:10.1109/wemdcd.2017.7947757 · Cited by 11
Guo, T., Chang, S., Chen, Z., Huang, H., & Xu, J. (2019) · IEEE Access · doi:10.1109/access.2019.2933881 · Cited by 9
Advancement of Fault Diagnosis and Detection Process in Industrial Machine Environment
Altaf, S., Mehmood, M., & Soomro, M. W. (2019) · Journal of Engineering Sciences · doi:10.21272/jes.2019.6(2).d1 · Cited by 10
Interturn fault diagnosis in brushless direct current motors — A review
Faiz, J., & Jafari, A. (2018) · IEEE International Conference on Industrial Technology (ICIT) · doi:10.1109/icit.2018.8352217 · Cited by 9
“In signal-based technique shock pulse, vibration, temperature, acoustic noise, electromagnetic field, infrared, gas analysis, oil analysis, RF emission, partial discharge, motor current signature, statistical analysis and instantaneous power variations are considered [11].”
BackgroundMethodStatistical Vibration-Based Fault Diagnosis Approach Applied To Brushless DC Motors
Alameh, K., Hoblos, G., & Barakat, G. (2018) · IFAC-PapersOnLine · doi:10.1016/j.ifacol.2018.09.599 · Cited by 11
Ferraris, L., Pošković, E., & Franchini, F. (2017) · IEEE International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED) · doi:10.1109/demped.2017.8062414 · Cited by 9
“In the case of permanent magnet (PM) electrical machines different typologies of components may be source of problems [3]-[5], as for instance ferromagnetic core, windings, electronic boards and, in some cases, also the permanent magnets [6].”
BackgroundNormalized-Model Reference System for Parameter Estimation of Induction Motors
Véliz-Tejo, A., Travieso‐Torres, J. C., Peters, A. A., Mora, A., & Leiva-Silva, F. (2022) · Energies · doi:10.3390/en15134542 · Cited by 9
Origin and manifestation of electrical machine faults-A review
Imoru, Ọ., Jimoh, A. A.-G., & Hamam, Y. (2014) · International Conference on Power Engineering and Renewable Energy (ICPERE) · doi:10.1109/icpere.2014.7067210 · Cited by 12
A Review of Fault Diagnosis Methods of Robot Joint Servo System
Wu, H. Q., & Feng, J. (2020) · IEEE International Conference on Mechatronics and Automation (ICMA) · doi:10.1109/icma49215.2020.9233583 · Cited by 13
Implementation and verification of the PMSM stator interturn short fault detection algorithm
Otava, L., & Buchta, L. (2017) · European Conference on Power Electronics and Applications · doi:10.23919/epe17ecceeurope.2017.8099080 · Cited by 8
“The most frequent fault in PMSMs is the bearing fault, and the second most common one is the stator winding fault [1].”
BackgroundLale, T., & Gümüş, B. (2023) · Electrical Engineering · doi:10.1007/s00202-023-02113-w · Cited by 8
Investigation of a Leakage Reactance Brushless DC Motor for DC Air Conditioning Compressor
Khlifi, M. A., Slimene, M. B., Alradedi, A., & Ahmadi, S. A. (2022) · Engineering Technology & Applied Science Research · doi:10.48084/etasr.4762 · Cited by 7
“Brush machines are generally inexpensive due to their established design and manufacturing technologies, as well as their simple control [7-10].”
BackgroundFault Diagnosis and Prognosis of a Brushless DC motor using a Model-based Approach
Blesa, J., Quevedo, J., Puig, V., Nejjari, F., Zaragoza, R., & Rolán, A. (2020) · PHM Society European Conference · doi:10.36001/phme.2020.v5i1.1257 · Cited by 11
“However, they can suffer from some failure due to overheating and mechanical wear (Da et al, 2011) and demagnetization (Moosavi et al., 2015).”
BackgroundPower management of a self-powered multi-parameter wireless sensor for IoT application
He, D., & Fahimi, B. (2018) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.2018.8341197 · Cited by 6
“These methods can be categorized as 1) current spectrum analysis, 2) vibration analysis, 3) temperature analysis, 4) radio-frequency (RF) emissions analysis, and 5) electromagnetic (EM) field monitoring [2-4].”
BackgroundMethodBouaissi, I., Laib, A., Rezig, A., Melit, M., Touati, S., Djerdir, A., & N’Diaye, A. (2024) · Electrical Engineering · doi:10.1007/s00202-023-02235-1 · Cited by 6
“…a set of rolling balls in the waterways; the reasons for bearing failure are due to several mechanical and electrical factors, as well as environmental conditions [3, 4], (magnetic imbalance, high temperature, unbalanced overload, thermal overloading, mis-alignment and even loss of lubrication).”
Detection of open circuit fault in battery power supply feeding permanent magnet synchronous motor
Breznik, M., Ambrozic, V., & Nemec, M. (2018) · IET Power Electronics · doi:10.1049/iet-pel.2018.5214 · Cited by 6
An On-line Detection Method for Single-Phase Inter-Turn Fault Occurring in High-Speed PMSM
Bao, L., Yao, G., Chen, S., Wang, Z., Hu, X., & Huang, Y. (2020) · International Conference on Electrical Machines and Systems (ICEMS) · doi:10.23919/icems50442.2020.9290898 · Cited by 6
“Among them, the inter-turn short circuit fault (ISF) of the stator winding accounts for 37% of all motor faults[2].”
BackgroundEsmeray, H., Doğan, Z., & İşeri, İ. (2025) · Evolving Systems · doi:10.1007/s12530-025-09710-z · Cited by 6
“The most common failures in LEVs are bearing failures (Mohanraj et al. 2022; Shifat and Hur 2020; Da et al. 2011; Vanchinathan et al. 2021).”
Diagnosing of BLDC Motor Faults based on LSSVM Model and Vibration Signal
Susilo, D. D., Ubaidillah, U., Prabowo, A. R., & Susilo, A. H. D. (2023) · E3S Web of Conferences · doi:10.1051/e3sconf/202346501024 · Cited by 7
“High working temperatures, overload, incorrect armature current, corrosion, metal fatigue, incorrect installation, and unbalance are the most common causes of these failures [3].”
BackgroundFuzzy logic inspired bearing fault-model membership estimation
Amar, M., Gondal, I., & Wilson, C. (2013) · International Conference on Intelligent Sensors, Sensor Networks and Information Processing · doi:10.1109/issnip.2013.6529827 · Cited by 5
“To extract and process machine health related information several signals, such as current, voltage, speed, vibration have been used [1,2].”
MethodFerraris, L., Franchini, F., & Pošković, E. (2019) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2019.2933801 · Cited by 5
A voltage based approach for fault detection and separation in permanent magnet synchronous machines
Haddad, R. Z., Lopez, C. A., Foster, S. N., & Strangas, E. G. (2016) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2016.7854806 · Cited by 6
“A few methods have been proposed to separate between different faults [7].”
MethodA BLDC fault diagnosis approach based on a super-twisting sliding mode observer
Mekki, A. E., & Saad, K. B. (2016) · International Conference on Control, Engineering & Information Technology · doi:10.1109/ceit.2016.7929039 · Cited by 5
Irreversible Demagnetization Fault Prognosis in a Permanent Magnet type Machines
Ullah, Z., & Hur, J. (2020) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce44975.2020.9235942 · Cited by 5
“Some prognostic strategies for different types of faults in the PM type machines are already proposed [12].”
BackgroundDetection and Compensation of Transistor and Position Sensors Faults in PM BLDCM Drives
Skóra, M., & Kowalski, C. T. (2016) · Studies in systems, decision and control · doi:10.1007/978-3-319-45735-2_9 · Cited by 5
Susilo, D. D., Ubaidillah, U., & Prabowo, A. R. (2024) · Diagnostyka · doi:10.29354/diag/191426 · Cited by 5
“These failures are caused mainly by high working temperature, overload, improper armature current, corrosion, metal fatigue, improper installation, and unbalance (3).”
BackgroundNovel Salient Stator Pole-Shoe Structure for Reducing Shaft-to-Frame Voltage of the PMSM
Lee, J.-S., Ahn, J.-M., Lim, D., & Kang, K. (2024) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2024.3519602 · Cited by 4
“Consequently, the EDM current damages the bearing, shortening the lifetime of the motor [2].”
Condition Monitoring and Fault Diagnosis for Hoisting System Driven by PMLSM
Zhang, H. W., Yu, F. S., Wang, X. H., & Bu, X. H. (2013) · Applied Mechanics and Materials · doi:10.4028/www.scientific.net/amm.416-417.521 · Cited by 4
“Influence of temperature on the magnetic remanence is approximately linear below Curie temperature [14] expressed in equation (3),”
BackgroundMethodInfluentialYu, X., Phạm, Đ. A., Li, X., & Doncker, R. W. D. (2022) · International Conference on Electrical Machines and Systems (ICEMS) · doi:10.1109/icems56177.2022.9983392 · Cited by 5
Metwly, M. Y., Clark, L., Xie, B., & He, J. (2024) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec48139.2024.10509158 · Cited by 4
“Several faults may happen in a BLDC motor drive , such as stator, rotor, or inverter semiconductor faults [13, 14].”
BackgroundModeling approach and fault index analysis of a voltage-source brushless DC motor
Alameh, K., Ginzarly, R., Hoblos, G., & Barakat, G. (2016) · Conference on Control and Fault-Tolerant Systems · doi:10.1109/systol.2016.7739807 · Cited by 4
An AI-based Architecture Framework for Improving End-of-line Reliability Tests of Electric Motors
Soytürk, M., Coşkun, K., Izmitlioglu, O., Tümer, B., Güneş, D., Saracoglu, S., Bulut, B., Ketmen, H. B., Hanedar, I., Asan, T., et al. (2022) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon49645.2022.9968853 · Cited by 3
“Defects in the manufacturing process and a high operating temperature are the two primary causes of winding insulation problems [17].”
BackgroundAnalysis of Stator Material Influence on BLDC Motor Performance
Ziemiański, D., Chwalik-Pilszyk, G., & Dudzik, G. (2025) · Materials · doi:10.3390/ma18194630 · Cited by 3
“According to Da et al. [10] and Shifat et al. [11], faults in BLDC motors can be classified into mechanical, electrical, and magnetic categories.”
Zubizarreta-Rodriguez, J. F., & Vasudevan, S. (2014) · IEEE/ASME International Conference on Advanced Intelligent Mechatronics · doi:10.1109/aim.2014.6878319 · Cited by 3
Schildt, P., Braun, C., & Marzocca, P. (2019) · CEAS Aeronautical Journal · doi:10.1007/s13272-019-00411-3 · Cited by 5
“, inverters and control system) on the other hand are expected not to be affected by mechanical excitation directly but as mentioned above there are effects which may manifest into current signature and, therefore, have to be kept in mind [4].”
BackgroundAnalysis of inherent shaft voltage in flux-switching permanent magnet machine
Li, W., Cheng, M., Zhu, S., & Hua, W. (2016) · Cited by 3
Condition monitoring of brushless DC motors with non-stationary dynamic conditions
Zubizarreta-Rodriguez, J. F., & Vasudevan, S. (2014) · IEEE International Instrumentation and Measurement Technology Conference · doi:10.1109/i2mtc.2014.6860523 · Cited by 3
“Different methods for signature extraction and analysis are discussed in [5].”
BackgroundMethodAnaliza wpływu wybranych uszkodzeń sterownika silnika PM BLDC na widma prądów fazowych
Skóra, M., & Kowalski, C. T. (2015) · Maszyny Elektryczne : zeszyty problemowe · Cited by 3
Anchehpoli, S. S. M. (2013) · theses.fr (ABES) · doi:10.70675/076de37fz92f0z4ec0z81bbz140d969ad791 · Cited by 6
Contribution au diagnostic et a l'analyse de défauts d'une machine synchrone à aimants permanents.
Alameh, K. (2017) · theses.fr (ABES) · doi:10.70675/6fe8e343za470z4e00z966cz63a61dcd75f3 · Cited by 3
Mınaz, M. R. (2020) · Bitlis Eren Üniversitesi Fen Bilimleri Dergisi · doi:10.17798/bitlisfen.595943 · Cited by 2
Said, H., & Nicoletti, T. (2015) · cIRcle (University of British Columbia) · doi:10.14288/1.0076365 · Cited by 2
“First, previous research on equipment and machine prognostics focused on monitoring the condition of stationary mechanical machines or electrical micro-machines by majorly measuring their vibrations (Dutta and Giurgiutiu 2000; Yan R. and Gao 2007; Da et al. 2011, Thomson 2013).”
MethodIntegrated diagnostic system for winding fault detection of the three-phase PMSM
Otava, L., & Buchta, L. (2020) · International Congress on Ultra Modern Telecommunications and Control Systems and Workshops (ICUMT) · doi:10.1109/icumt51630.2020.9222438 · Cited by 2
“The second most frequent motor fault is the stator winding fault [1].”
BackgroundFAULT DETECTION AND IDENTIFICATION IN PERMANENT MAGNET SYNCHRONOUS MACHINES
Haddad, R. Z. (2016) · Michigan State University Libraries · doi:10.25335/m53b1t · Cited by 8
Optimum feature extraction and selection for automatic fault diagnosis of reluctance motors
Bouchareb, I., Lebaroud, A., & Bentounsi, A. (2014) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2014.7049011 · Cited by 1
Machine Learning based Fault Detection for Non-Linear Systems
Harikrishna, B., & Kanagalakshmi, S. (2023) · International Conference on Smart Computing and Communications (ICSCC) · doi:10.1109/icscc59169.2023.10335072 · Cited by 1
“Y. Da, et al. [1] this study, the mechanical, field, and armature faults that can impact PMSM were briefly addressed, along with the numerous diagnostic techniques.”
BackgroundYu, X., Pham, D. H., Braun, L., & Doncker, R. W. D. (2024) · IEEE Annual Southern Power Electronics Conference · doi:10.1109/spec62217.2024.10893089 · Cited by 2
Review on Advanced Computing Control Techniques in BLDC Motors for Electrical Vehicles
Prasad, K. S. R. V., & Reddy, V. U. (2025) · International Conference on Intelligent Data Communication Technologies and Internet of Things (IDCIoT) · doi:10.1109/idciot64235.2025.10914796 · Cited by 1
“Inter-Turn SVM methods [31] Offline Simulation Hybrid analytical-numerical approach [31] Offline Simulation RNN, LSTM [32] Offline Experimental Self-encoding convolutional network model [33] Online Simulation Coil-to-coil Fast Kurtogram autogram, MCSA [34] Offline Experimental Phase-to-phase ANN…”
Development of On-Board Systems of Predictive Diagnostics of Electric Rolling Stock Traction Motor
Pastukhov, K., Istomin, S. G., & Yrasov, O. (2022) · Lecture notes in networks and systems · doi:10.1007/978-3-031-11051-1_14 · Cited by 1
Small Wind Turbine Generator Condition Monitoring: Test Rig and Preliminary Analysis
Cai, H. (2014) · Libraries and Cultural Resources (University of Calgary) · doi:10.11575/prism/27803 · Cited by 1
Autonomous behavior modeling approach for diverse anomaly detection application
Amar, M., Wilson, C., & Gondal, I. (2014) · International Conference on Open Source Systems and Technologies (ICOSST) · doi:10.1109/icosst.2014.7029331
Fault Detection and Just‐in‐Time Maintenance in Adjustable‐Speed Drives
Krishnamurthy, M., & Da, Y. (2012) · Wiley eBooks · doi:10.1002/047134608x.w8127
Self-citationComplex anomaly for enhanced machine independent condition monitoring
Amar, M., Gondal, I., & Wilson, C. (2015) · International Conference on Open Source Systems and Technologies (ICOSST) · doi:10.1109/icosst.2015.7396409
“For modeling, time, frequency or both domain based features are used in literature [1], [4], [7]-[12].”
BackgroundMethodWybrane metody badań maszyn elektrycznych z magnesami trwałymi
Jarek, T. (2015) · Maszyny Elektryczne : zeszyty problemowe
Gómez, I., Zarate, S., Almandoz, G., Poza, J., Ugalde, G., & Escalada, A. J. (2016) · International Conference on Electrical Machines (ICEM) · doi:10.1109/icelmach.2016.7732520
Praca napędu z silnikiem PM BLDC w warunkach awarii tranzystora komutatora elektronicznego
Skóra, M. (2016) · PRZEGLĄD ELEKTROTECHNICZNY · doi:10.15199/48.2016.06.09
High-Frequency Signal Injection-Based Various Cable Connection Fault Diagnostics of PMSM
Li, Y., Xu, W., Wang, J., Jin, Z., & Fang, S. (2024) · Lecture notes in electrical engineering · doi:10.1007/978-981-97-1064-5_3
Thakur, H., Pindoriya, R. M., & Prakash, S. (2025) · IEEE International Conference on Sustainable Energy and Future Electric Transportation (SEFET) · doi:10.1109/sefet65155.2025.11255337
“An open-circuit failure is caused by a break in the wire [6].”
Diagnosis of BLDC motor faults at different speed conditions using LSSVM
Susilo, D. D., Ubaidillah, U., & Prabowo, A. R. (2025) · AIP conference proceedings · doi:10.1063/5.0282405
Loss Modeling and Performance Comparison of a 150kW Seven-Level Interleaved ANPC Inverter
Yu, H., Zhang, C., Zheng, Q., Lei, D., Liu, J., & Li, L. (2025) · International Conference on Electrical Machines and Systems (ICEMS) · doi:10.23919/icems66262.2025.11316954
“Consequently, the EDM current damages the bearing, shortening the lifetime of the motor, as in [2][3][4][5].”
GUI Based BLDC Motor Health Monitoring System
Mohan, N., Ravishankar, B. S., T, K. P., Aravinda, Sneha, V., & C, S. H. (2025) · IEEE North Karnataka Subsection Flagship International Conference (NKCon) · doi:10.1109/nkcon66957.2025.11345761
Yu, X., Pham, D. H., Braun, L., & Doncker, R. W. D. (2025) · IEEE Transportation Electrification Conference and Expo, Asia-Pacific (ITEC Asia-Pacific) · doi:10.1109/itecasia-pacific63742.2025.11344929
“One of the most frequent and critical faults in PMSM is the occurrence of inter-turn short circuits (ITSCs) caused by electrical or thermal stresses [1]–[3].”
Shestakov, A. L., Galyshev, D. V., Eremeeva, V. A., & Ibryaeva, O. L. (2026) · International Conference on Digital Signal Processing and its Applications (DSPA) · doi:10.1109/dspa69176.2026.11476735 · Cited by 1
“According to IEEE and EPRI statistical data [3], [4], stator winding failures account for 36% to 66% of all alternating current machine faults.”
Thakur, H., Pindoriya, R. M., & Prakash, S. (2026) · IETE Journal of Research · doi:10.1080/03772063.2026.2683552
Real Time Estimation, Quantization, And Remote Control Of Permanent Magnet Dc Motors
Obeidat, M. A. (2013) · Human Biology
Analysis and design of fault tolerant axial flux permanent magnet synchronous motors
Ordóñez, H. S. (2015) · UPCommons institutional repository (Universitat Politècnica de Catalunya) · doi:10.5821/dissertation-2117-95638
Metadata
- Authors
- Da, Y., Shi, X., & Krishnamurthy, M.
- Affiliations
- Illinois Institute of Technology (US)
- Venue
- 2011 IEEE Vehicle Power and Propulsion Conference
- Publisher
- IEEE
- Published
- 2011-09
- Pages
- 1-7
- OpenAlex
- W2127013354
- Cited by
- 96
- References
- 62
- Citations by year
- 2026: 2 · 2025: 8 · 2024: 9 · 2023: 3 · 2022: 10 · 2021: 3 · 2020: 14 · 2019: 5 · 2018: 5 · 2017: 5 · 2016: 10 · 2015: 7 · 2014: 9 · 2013: 4 · 2012: 2
- FWCI
- 8.03
- Type
- conference paper
- Language
- en
- Open access
- closed
- Locations
- IEEE Vehicle Power and Propulsion Conference (VPPC) (publishedVersion)
- Topics
- Physical Sciences › Engineering › Control and Systems Engineering › Machine Fault Diagnosis Techniques
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electric Motor Design and Analysis
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Sensorless Control of Electric Motors
- Keywords
- permanent magnet brushless machines, condition monitoring, fault diagnosis, failure prediction, health monitoring, rare-earth permanent magnets, predictive maintenance
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.