A MICS Band Wireless Body Sensor Network
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
This paper presents a MICS (medical implant communication service) based body sensor network design and implementation for patient physiological data collection for health monitoring purposes. The MICS band offers the advantage of miniaturized electronic devices that can either be used as an implanted node or as an external node. In this work, a prototype sensor network is implemented by incorporating temperature and pulse rate sensors on nodes. Each developed sensor node has the capability of physiological data acquisition and local processing. The sensor node can also transmit data over the air to a remote central control unit (CCU) for further processing and storage. The developed system offers medical staff to obtain patient's physiological data on demand basis via the Internet. Moreover, the system has been optimized for power consumption by using a polling architecture. Some preliminary performance data is presented in the paper.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
AMON: A Wearable Multiparameter Medical Monitoring and Alert System
Anliker, U., Ward, J. A., Lukowicz, P., Troster, G., Dolveck, F., Baer, M., Keita, F., Schenker, E. B., Catarsi, F., Coluccini, L., et al. (2004) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2004.837888 · Cited by 707 · cited 1×
“and more. The wireless data transfer part of the Fig. 8 is targeting to use the mobile/cellular network systems as being done by the projects in [4][ 5 ].”
Method
Cited by
A Survey on Wearable Sensor-Based Systems for Health Monitoring and Prognosis
Pantelopoulos, A., & Bourbakis, N. G. (2010) · IEEE Transactions on Systems Man and Cybernetics Part C (Applications and Reviews) · doi:10.1109/tsmcc.2009.2032660 · Cited by 2,296
“for transmitting low-rate data in support of diagnostic or therapeutic functions associated with medical devices [16].”
BackgroundWireless Body Area Networks: A Survey
Movassaghi, S., Abolhasan, M., Lipman, J., Smith, D., & Jamalipour, A. (2014) · IEEE Communications Surveys & Tutorials · doi:10.1109/surv.2013.121313.00064 · Cited by 1,538
Wearable Wireless Health Monitoring: Current Developments, Challenges, and Future Trends
Soh, P. J., Vandenbosch, G. A. E., Mercuri, M., & Schreurs, D. M. M.-P. (2015) · IEEE Microwave Magazine · doi:10.1109/mmm.2015.2394021 · Cited by 253
“MICS is an ultralow-power, unlicensed mobile radio service for transmitting low-rate data in support of diagnostic or therapeutic functions associated with medical devices [16].”
BackgroundA Survey on Security and Privacy Issues in Modern Healthcare Systems: Attacks and Defenses
Newaz, A. I., Sikder, A. K., Rahman, M. A., & Uluagac, A. S. (2021) · ACM Transactions on Computing for Healthcare · doi:10.1145/3453176 · Cited by 225
“d, mobile radio service for transmitting low-rate data in support of diagnostic or therapeutic functions associated with medical devices. It uses the 402-405 MHz frequency band, with 300 kHz channels [36]. For long-range communication between a healthcare system and a health server or a healthcare provider, there is a…”
BackgroundBody Area Networks for Ubiquitous Healthcare Applications: Opportunities and Challenges
Jovanov, E., & Milenkovic, A. (2011) · Journal of Medical Systems · doi:10.1007/s10916-011-9661-x · Cited by 183
“& Zigbee [10] & Ant [11] & MICS [ 33 ] & Ultra Wide Band UWB [24] & Custom protocols [34][35]”
Background
Metadata
- Authors
- Yuce, M. R., Ng, S. W. P., Myo, N. L., Lee, C. K., Khan, J. Y., & Liu, W.
- Venue
- 2007 IEEE Wireless Communications and Networking Conference
- Publisher
- IEEE
- Published
- 2007
- Pages
- 2473-2478
- ISSN
- 1525-3511 (ISSN-L)
- OpenAlex
- W2132224959
- Cited by
- 37
- References
- 1
- FWCI
- 6.90
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.