Detection of intact megaDalton protein assemblies of vanillyl‐alcohol oxidase by mass spectrometry
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Well‐resolved ion signals of intact large protein assemblies, with molecular masses extending above one million Dalton, have been detected and mass analyzed using electrospray ionization mass spectrometry, with an uncertainty in mass of <0.2%. the mass spectral data seem to reflect known solution‐phase behavior of the studied protein assembly and have therefore been directly used to probe the protein assembly topology and stability as a function of ionic strength and ph.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrospray Ionization for Mass Spectrometry of Large Biomolecules
Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., & Whitehouse, C. M. (1989) · Science · doi:10.1126/science.2675315 · Cited by 7,634 · cited 1×
“~Fenn et al., 1989!, the detectable mass range of biomacromolecular systems by mass spectrometry has been immensely extended~McLafferty, 1994; Smith et al., 1994!. Additionally, the relatively gentle phase transfer from solution to the gas phase, realized by in particular electrospray ionization,…”
Background
Cited by
Towards single-molecule nanomechanical mass spectrometry
Naik, A. K., Hanay, M. S., Hiebert, W. K., Feng, X. L., & Roukes, M. L. (2009) · Nature Nanotechnology · doi:10.1038/nnano.2009.152 · Cited by 683
Native Mass Spectrometry: What is in the Name?
Leney, A. C., & Heck, A. J. R. (2017) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-016-1545-3 · Cited by 602
“modified their quadrupole (Q)-ToF mass spectrometers [40, 41], which together with elegant work on the optimization and transmission of high m/z ions [42, 43], enabled tandem MS experiments to be performed on large protein complexes, providing information not only on protein complex stoichiometry but also on protein c…”
BackgroundSelf-citationInvestigation of intact protein complexes by mass spectrometry
Heck, A. J. R., & van den Heuvel, R. H. H. (2004) · Mass Spectrometry Reviews · doi:10.1002/mas.10081 · Cited by 583
Self-citationDaniel, J. M., Friess, S. D., Rajagopalan, S., Wendt, S., & Zenobi, R. (2002) · International Journal of Mass Spectrometry · doi:10.1016/s1387-3806(02)00585-7 · Cited by 475
Loo, J. A. (2000) · International Journal of Mass Spectrometry · doi:10.1016/s1387-3806(00)00298-0 · Cited by 444
Bosch, B. J., Martina, B. E. E., van der Zee, R., Lepault, J., Haijema, B. J., Versluis, C., Heck, A. J. R., de Groot, R., Osterhaus, A. D. M. E., & Rottier, P. J. M. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0400576101 · Cited by 416
Self-citationThe Role of Mass Spectrometry in Structure Elucidation of Dynamic Protein Complexes
Sharon, M., & Robinson, C. V. (2007) · Annual Review of Biochemistry · doi:10.1146/annurev.biochem.76.061005.090816 · Cited by 357
Smith, D. P., Knapman, T. W., Campuzano, I., Malham, R. W., Berryman, J. T., Radford, S. E., & Ashcroft, A. E. (2009) · European Journal of Mass Spectrometry · doi:10.1255/ejms.947 · Cited by 334
Lengqvist, J., Mata de Urquiza, A., Bergman, A.-C., Willson, T. M., Sjövall, J., Perlmann, T., & Griffiths, W. J. (2004) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m400003-mcp200 · Cited by 323
Native protein mass spectrometry: from intact oligomers to functional machineries
Heuvel, R. H. V. D., & Heck, A. J. (2004) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2004.08.006 · Cited by 303
Self-citationLi, H., Nguyen, H. H., Ogorzalek Loo, R. R., Campuzano, I. D. G., & Loo, J. A. (2018) · Nature Chemistry · doi:10.1038/nchem.2908 · Cited by 249
“Conventionally, native MS studies of protein complexes have been mostly performed using quadrupole time-of-flight (Q-TOF) MS instruments due to the high transmission efficiency of TOF for high m/z ions 6, 7 .”
Metadata
- Authors
- Van Berkel, W. J. H., Van Den Heuvel, R. H. H., Versluis, C., & Heck, A. J. R.
- Venue
- Protein Science
- Publisher
- Wiley
- Published
- 2000-01
- Volume
- 9
- Issue
- 3
- Pages
- 435-439
- ISSN
- 0961-8368 (ISSN-L)
- 1469-896X
- OpenAlex
- W2114580860
- Cited by
- 116
- References
- 1
- FWCI
- 6.57
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.