CoChat

Software‐Related Recalls of Health Information Technology and Other Medical Devices: Implications for FDA Regulation of Digital Health

Open access
RONQUILLO, JAY G., ZUCKERMAN, DIANA M. · 2017 · The Milbank Quarterly
Cited by 81

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

Policy Points: Medical software has become an increasingly critical component of health care, yet the regulation of these devices is inconsistent and controversial. No studies of medical devices and software assess the impact on patient safety of the FDA's current regulatory safeguards and new legislative changes to those standards. Our analysis quantifies the impact of software problems in regulated medical devices and indicates that current regulations are necessary but not sufficient for ensuring patient safety by identifying and eliminating dangerous defects in software currently on the market. New legislative changes will further deregulate health IT, reducing safeguards that facilitate the reporting and timely recall of flawed medical software that could harm patients. Context: Medical software has become an increasingly critical component of health care, yet the regulatory landscape for digital health is inconsistent and controversial. To understand which policies might best protect patients, we examined the impact of the US Food and Drug Administration's (FDA's) regulatory safeguards on software‐related technologies in recent years and the implications for newly passed legislative changes in regulatory policy. Methods: Using FDA databases, we identified all medical devices that were recalled from 2011 through 2015 primarily because of software defects. We counted all software‐related recalls for each FDA risk category and evaluated each high‐risk and moderate‐risk recall of electronic medical records to determine the manufacturer, device classification, submission type, number of units, and product details. Findings: A total of 627 software devices (1.4 million units) were subject to recalls, with 12 of these devices (190,596 units) subject to the highest‐risk recalls. Eleven of the devices recalled as high risk had entered the market through the FDA review process that does not require evidence of safety or effectiveness, and one device was completely exempt from regulatory review. The largest high‐risk recall categories were anesthesiology and general hospital, with one each in cardiovascular and neurology. Five electronic medical record systems (9,347 units) were recalled for software defects classified as posing a moderate risk to patient safety. Conclusions: Software problems in medical devices are not rare and have the potential to negatively influence medical care. Premarket regulation has not captured all the software issues that could harm patients, evidenced by the potentially large number of patients exposed to software products later subject to high‐risk and moderate‐risk recalls. Provisions of the 21st Century Cures Act that became law in late 2016 will reduce safeguards further. Absent stronger regulations and implementation to create robust risk assessment and adverse event reporting, physicians and their patients are likely to be at risk from medical errors caused by software‐related problems in medical devices.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/1468-0009.12278

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

See all 81

Metadata

Authors
RONQUILLO, J. G., & ZUCKERMAN, D. M.
Venue
The Milbank Quarterly
Publisher
Wiley
Published
2017-09
Volume
95
Issue
3
Pages
535-553
ISSN
  • 0887-378X (ISSN-L)
  • 1468-0009
OpenAlex
W2755403817
Cited by
81
References
8
FWCI
4.98
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Software‐Related Recalls of Health Information Technology and Other Medical Devices: Implications for FDA Regulation of Digital Health. https://app.cochat.ai/papers/10.1111/1468-0009.12278
The paper
RONQUILLO, J. G., & ZUCKERMAN, D. M. (2017). Software‐Related Recalls of Health Information Technology and Other Medical Devices: Implications for FDA Regulation of Digital Health. The Milbank Quarterly. https://doi.org/10.1111/1468-0009.12278

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.