A stratified analysis of a deep learning algorithm in the diagnosis of diabetic retinopathy in a real‐world study
Open accessThe DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
Background: The aim of our research was to prospectively explore the clinical value of a deep learning algorithm (DLA) to detect referable diabetic retinopathy (DR) in different subgroups stratified by types of diabetes, blood pressure, sex, BMI, age, glycosylated hemoglobin (HbA1c), diabetes duration, urine albumin‐to‐creatinine ratio (UACR), and estimated glomerular filtration rate (eGFR) at a real‐world diabetes center in China. Methods: A total of 1147 diabetic patients from Shanghai General Hospital were recruited from October 2018 to August 2019. Retinal fundus images were graded by the DLA, and the detection of referable DR (moderate nonproliferative DR or worse) was compared with a reference standard generated by one certified retinal specialist with more than 12 years of experience. The performance of DLA across different subgroups stratified by types of diabetes, blood pressure, sex, BMI, age, HbA1c, diabetes duration, UACR, and eGFR was evaluated. Results: For all 1674 gradable images, the area under the receiver operating curve, sensitivity, and specificity of the DLA for referable DR were 0.942 (95% CI, 0.920‐0.964), 85.1% (95% CI, 83.4%‐86.8%), and 95.6% (95% CI, 94.6%‐96.6%), respectively. The DLA showed consistent performance across most subgroups, while it showed superior performance in the subgroups of patients with type 1 diabetes, UACR ≥ 30 mg/g, and eGFR < 90 mL/min/1.73m 2. Conclusions: This study showed that the DLA was a reliable alternative method for the detection of referable DR and performed superior in patients with type 1 diabetes and diabetic nephropathy who were prone to DR.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
LeCun, Y., Bengio, Y., & Hinton, G. (2015) · Nature · doi:10.1038/nature14539 · Cited by 84,126
Stevens, P. E., Levin, A., & for the Kidney Disease: Improving Global Outcomes Chronic Kidney Disease Guideline Development Work Group Members* (2013) · Annals of Internal Medicine · doi:10.7326/0003-4819-158-11-201306040-00007 · Cited by 3,607
Cheung, N., Mitchell, P., & Wong, T. Y. (2010) · The Lancet · doi:10.1016/s0140-6736(09)62124-3 · Cited by 3,288
Ting, D. S. W., Cheung, C. Y.-L., Lim, G., Tan, G. S. W., Quang, N. D., Gan, A., Hamzah, H., Garcia-Franco, R., San Yeo, I. Y., Lee, S. Y., et al. (2017) · JAMA · doi:10.1001/jama.2017.18152 · Cited by 2,402
Abràmoff, M. D., Lou, Y., Erginay, A., Clarida, W., Amelon, R., Folk, J. C., & Niemeijer, M. (2016) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.16-19964 · Cited by 1,101
Ting, D. S. W., Cheung, G. C. M., & Wong, T. Y. (2016) · Clinical & Experimental Ophthalmology · doi:10.1111/ceo.12696 · Cited by 1,066
11. Microvascular Complications and Foot Care: Standards of Medical Care in Diabetes—2021
American Diabetes Association (2021) · Diabetes Care · doi:10.2337/dc21-s011 · Cited by 395
Gulshan, V., Rajan, R. P., Widner, K., Wu, D., Wubbels, P., Rhodes, T., Whitehouse, K., Coram, M., Corrado, G., Ramasamy, K., et al. (2019) · JAMA Ophthalmology · doi:10.1001/jamaophthalmol.2019.2004 · Cited by 303
Li, Z., Keel, S., Liu, C., He, Y., Meng, W., Scheetz, J., Lee, P. Y., Shaw, J., Ting, D., Wong, T. Y., et al. (2018) · Diabetes Care · doi:10.2337/dc18-0147 · Cited by 255 · cited 1×
“9,10 11-16 However, a majority of DLA systems have been validated using online curated or publicly available datasets (EyePACS, Messidor-2, e-ophtha), 11,12,15 which contained high-quality photographs from individuals.”
MethodVerbraak, F. D., Abramoff, M. D., Bausch, G. C. F., Klaver, C., Nijpels, G., Schlingemann, R. O., & van der Heijden, A. A. (2019) · Diabetes Care · doi:10.2337/dc18-0148 · Cited by 115 · cited 2×
“For DR detection, DLA have demonstrated excellent sensitivity and specificity, and have been shown to produce expertlevel diagnoses for grading fundus photographs.(4,11-16) However, a majority of DLA systems have been validated using online curated or publicly available datasets (EyePACS, Messidor-2, e-ophtha),(11,12,…”
BackgroundMethod
Cited by
Wang, Y., Liu, C., Hu, W., Luo, L., Shi, D., Zhang, J., Yin, Q., Zhang, L., Han, X., & He, M. (2024) · npj Digital Medicine · doi:10.1038/s41746-024-01032-9 · Cited by 76
Self-citationJOSEPH, S., SELVARAJ, J., MANI, I., KUMARAGURUPARI, T., SHANG, X., MUDGIL, P., RAVILLA, T., & HE, M. (2024) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2024.02.012 · Cited by 69
Wang, Z., Li, Z., Li, K., Mu, S., Zhou, X., & Di, Y. (2023) · Frontiers in Endocrinology · doi:10.3389/fendo.2023.1197783 · Cited by 27
“(22) 2022 China retinal specialist RDR 147 44 9 947 1147 Sh”
Self-citationMoannaei, M., Jadidian, F., Doustmohammadi, T., Kiapasha, A. M., Bayani, R., Rahmani, M., Jahanbazy, M. R., Sohrabivafa, F., Asadi Anar, M., Magsudy, A., et al. (2025) · BioMedical Engineering OnLine · doi:10.1186/s12938-025-01336-1 · Cited by 18
“The DLA graded retinal fundus images; for all 1674 gradable images the AUC, sensitivity, and specificity of the DLA for referable DR were 0.942, 85.1%, and 95.6%, respectively [23].”
Influential
Metadata
- Authors
- Li, N., Ma, M., Lai, M., Gu, L., Kang, M., Wang, Z., Jiao, S., Dang, K., Deng, J., Ding, X., Zhen, Q., Zhang, A., Shen, T., Zheng, Z., Wang, Y., & Peng, Y.
- Venue
- Journal of Diabetes
- Publisher
- Wiley
- Published
- 2021-12-09
- Volume
- 14
- Issue
- 2
- Pages
- 111-120
- ISSN
- 1753-0393 (ISSN-L)
- 1753-0407
- OpenAlex
- W4200085948
- Cited by
- 32
- References
- 10
- FWCI
- 2.67
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A stratified analysis of a deep learning algorithm in the diagnosis of diabetic retinopathy in a real‐world study. https://app.cochat.ai/papers/10.1111/1753-0407.13241
- The paper
- Li, N., Ma, M., Lai, M., Gu, L., Kang, M., Wang, Z., Jiao, S., Dang, K., Deng, J., Ding, X., Zhen, Q., Zhang, A., Shen, T., Zheng, Z., Wang, Y., & Peng, Y. (2022). A stratified analysis of a deep learning algorithm in the diagnosis of diabetic retinopathy in a real‐world study. Journal of Diabetes. https://doi.org/10.1111/1753-0407.13241
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.