CoChat

The McGrath ® Series 5 videolaryngoscope vs the Macintosh laryngoscope: a randomised, controlled trial in patients with a simulated difficult airway

Taylor, A. M., Peck, M., Launcelott, S., Hung, O. R., Law, J. A., MacQuarrie, K., McKeen, D., George, R. B., Ngan, J. · 2013 · Anaesthesia
Cited by 107

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Summary: We compared the McGrath ® Series 5 videolaryngoscope with the Macintosh laryngoscope in a simulated difficult airway, using manual in‐line stabilisation in 88 anaesthestised patients of ASA physical status 1‐2. The primary outcome was laryngoscopic view. Secondary outcomes included rates of successful tracheal intubation and complications. A Cormack and Lehane grade‐1 or ‐2 view was found in all patients when using the McGrath compared with 45 (51%, p < 0.0001) using the Macintosh laryngoscopes. The mean (SD) percentage of glottic opening was 82 (23)% using the McGrath compared with 13 (23)% using the Macintosh (p < 0.0001). In 66 out of 88 patients (75%), the McGrath improved the glottic view by one to three grades compared with the Macintosh (p < 0.001). Intubation of the trachea was successful in all patients using the McGrath, while the Macintosh was successful in 26 (59%, p < 0.001). There was no significant difference in the complication rates between the devices.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/anae.12075

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 107

Metadata

Authors
Taylor, A. M., Peck, M., Launcelott, S., Hung, O. R., Law, J. A., MacQuarrie, K., McKeen, D., George, R. B., & Ngan, J.
Venue
Anaesthesia
Publisher
Wiley
Published
2012-11-05
Volume
68
Issue
2
Pages
142-147
ISSN
  • 0003-2409 (ISSN-L)
  • 1365-2044
OpenAlex
W2056239200
Cited by
107
References
2
FWCI
13.85
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The McGrath ® Series 5 videolaryngoscope vs the Macintosh laryngoscope: a randomised, controlled trial in patients with a simulated difficult airway. https://app.cochat.ai/papers/10.1111/anae.12075
The paper
Taylor, A. M., Peck, M., Launcelott, S., Hung, O. R., Law, J. A., MacQuarrie, K., McKeen, D., George, R. B., & Ngan, J. (2013). The McGrath ® Series 5 videolaryngoscope vs the Macintosh laryngoscope: a randomised, controlled trial in patients with a simulated difficult airway. Anaesthesia. https://doi.org/10.1111/anae.12075

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.