The microbiological and sustainability effects of washing anaesthesia breathing circuits less frequently
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Summary: In the presence of single‐use airway filters, we quantified anaesthetic circuit aerobic microbial contamination rates when changed every 24 h, 48 h and 7 days. Microbiological samples were taken from the interior of 305 anaesthetic breathing circuits over a 15‐month period (3197 operations). There was no significant difference in the proportion of contaminated circuits when changed every 24 h (57/105 (54%, 95% CI 45–64%)) compared with 48 h (43/100 (43%, 95% CI 33–53%, p = 0.12)) and up to 7 days (46/100 (46%, 95% CI 36–56%, p = 0.26)). Median bacterial counts were not increased at 48 h or 7 days provided circuits were routinely emptied of condensate. Annual savings for one hospital (six operating theatres) were $AU 5219 (£3079, €3654, $US 4846) and a 57% decrease in anaesthesia circuit steriliser loads associated with a yearly saving of 2760 kWh of electricity and 48 000 l of water. Our findings suggest that extended circuit use from 24 h up to 7 days does not significantly increase bacterial contamination, and is associated with labour, energy, water and financial savings.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ecological responsibility in anesthesia practice
Sherman, J. D., & Ryan, S. (2010) · International Anesthesiology Clinics · doi:10.1097/aia.0b013e3181ea7587 · Cited by 67
Cited by
Environmental sustainability in anaesthesia and critical care
McGain, F., Muret, J., Lawson, C., & Sherman, J. D. (2020) · British Journal of Anaesthesia · doi:10.1016/j.bja.2020.06.055 · Cited by 455
Self-citationFinancial and environmental costs of reusable and single-use anaesthetic equipment
McGain, F., Story, D., Lim, T., & McAlister, S. (2017) · British Journal of Anaesthesia · doi:10.1093/bja/aex098 · Cited by 206
Self-citationCarbon footprint of general, regional, and combined anesthesia for total knee replacements
McGain, F., Sheridan, N., Wickramarachchi, K., Yates, S., Chan, B., & McAlister, S. (2021) · Anesthesiology · doi:10.1097/aln.0000000000003967 · Cited by 144
Self-citationNeue Herausforderungen für die Anästhesie durch den Klimawandel
Koch, S., & Pecher, S. (2020) · Der Anaesthesist · doi:10.1007/s00101-020-00770-1 · Cited by 39
Lighting a candle, or cursing the darkness? Delivering a climate friendly anaesthetic
Skowno, J., & Weatherall, A. (2021) · Journal of Paediatrics and Child Health · doi:10.1111/jpc.15760 · Cited by 10
Metadata
- Authors
- McGain, F., Algie, C. M., O'Toole, J., Lim, T. F., Mohebbi, M., Story, D. A., & Leder, K.
- Venue
- Anaesthesia
- Publisher
- Wiley
- Published
- 2014-02-06
- Volume
- 69
- Issue
- 4
- Pages
- 337-342
- ISSN
- 0003-2409 (ISSN-L)
- 1365-2044
- OpenAlex
- W1970663100
- Cited by
- 44
- References
- 1
- FWCI
- 1.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The microbiological and sustainability effects of washing anaesthesia breathing circuits less frequently. https://app.cochat.ai/papers/10.1111/anae.12563
- The paper
- McGain, F., Algie, C. M., O'Toole, J., Lim, T. F., Mohebbi, M., Story, D. A., & Leder, K. (2014). The microbiological and sustainability effects of washing anaesthesia breathing circuits less frequently. Anaesthesia. https://doi.org/10.1111/anae.12563
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.