The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Transnasal Humidified Rapid‐Insufflation Ventilatory Exchange (THRIVE): a physiological method of increasing apnoea time in patients with difficult airways
Open accessAbstract
Summary: Emergency and difficult tracheal intubations are hazardous undertakings where successive laryngoscopy–hypoxaemia–re‐oxygenation cycles can escalate to airway loss and the ‘can't intubate, can't ventilate’ scenario. Between 2013 and 2014, we extended the apnoea times of 25 patients with difficult airways who were undergoing general anaesthesia for hypopharyngeal or laryngotracheal surgery. This was achieved through continuous delivery of transnasal high‐flow humidified oxygen, initially to provide pre‐oxygenation, and continuing as post‐oxygenation during intravenous induction of anaesthesia and neuromuscular blockade until a definitive airway was secured. Apnoea time commenced at administration of neuromuscular blockade and ended with commencement of jet ventilation, positive‐pressure ventilation or recommencement of spontaneous ventilation. During this time, upper airway patency was maintained with jaw‐thrust. Transnasal Humidified Rapid‐Insufflation Ventilatory Exchange (THRIVE) was used in 15 males and 10 females. Mean (SD [range]) age at treatment was 49 (15 [25–81]) years. The median (IQR [range]) Mallampati grade was 3 (2–3 [2–4]) and direct laryngoscopy grade was 3 (3–3 [2–4]). There were 12 obese patients and nine patients were stridulous. The median (IQR [range]) apnoea time was 14 (9–19 [5–65]) min. No patient experienced arterial desaturation < 90%. Mean (SD [range]) post‐apnoea end‐tidal (and in four patients, arterial) carbon dioxide level was 7.8 (2.4 [4.9–15.3]) kPa. The rate of increase in end‐tidal carbon dioxide was 0.15 kPa.min −1 . We conclude that THRIVE combines the benefits of ‘classical’ apnoeic oxygenation with continuous positive airway pressure and gaseous exchange through flow‐dependent deadspace flushing. It has the potential to transform the practice of anaesthesia by changing the nature of securing a definitive airway in emergency and difficult intubations from a pressured stop–start process to a smooth and unhurried undertaking.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Difficult tracheal intubation in obstetrics
CORMACK, R. S., & LEHANE, J. (1984) · Anaesthesia · doi:10.1111/j.1365-2044.1984.tb08932.x · Cited by 2,471
Cook, T. M., Woodall, N., & Frerk, C. (2011) · British Journal of Anaesthesia · doi:10.1093/bja/aer058 · Cited by 2,415
Difficult tracheal intubation: a retrospective study
SAMSOON, G. L. T., & YOUNG, J. R. B. (1987) · Anaesthesia · doi:10.1111/j.1365-2044.1987.tb04039.x · Cited by 1,584
Jaber, S., Amraoui, J., Lefrant, J.-Y., Arich, C., Cohendy, R., Landreau, L., Calvet, Y., Capdevila, X., Mahamat, A., & Eledjam, J.-J. (2006) · Critical Care Medicine · doi:10.1097/01.ccm.0000233879.58720.87 · Cited by 675
Preoxygenation and prevention of desaturation during emergency airway management
Weingart, S. D., & Levitan, R. M. (2012) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2011.10.002 · Cited by 554 · cited 1×
“Pre-oxygenation denitrogenises the lungs and creates an alveolar oxygen reservoir [6].”
An electronic application for rapidly calculating Charlson comorbidity score
Hall, W. H., Ramachandran, R., Narayan, S., Jani, A. B., & Vijayakumar, S. (2004) · BMC Cancer · doi:10.1186/1471-2407-4-94 · Cited by 532
High-flow Oxygen Therapy in Acute Respiratory Failure
Masclans, J. R., & Roca, O. (2012) · Clinical Pulmonary Medicine · doi:10.1097/cpm.0b013e3182514f29 · Cited by 489
Noninvasive Ventilation Improves Preoxygenation before Intubation of Hypoxic Patients
Baillard, C., Fosse, J.-P., Sebbane, M., Chanques, G., Vincent, F., Courouble, P., Cohen, Y., Eledjam, J.-J., Adnet, F., & Jaber, S. (2006) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200509-1507oc · Cited by 478
Dixon, B. J., Dixon, J. B., Carden, J. R., Burn, A. J., Schachter, L. M., Playfair, J. M., Laurie, C. P., & O’Brien, P. E. (2005) · Anesthesiology · doi:10.1097/00000542-200506000-00009 · Cited by 462
Complications of endotracheal intubation in the critically ill
Griesdale, D. E. G., Bosma, T. L., Kurth, T., Isac, G., & Chittock, D. R. (2008) · Intensive Care Medicine · doi:10.1007/s00134-008-1205-6 · Cited by 443
Cited by
Frerk, C., Mitchell, V. S., McNarry, A. F., Mendonca, C., Bhagrath, R., Patel, A., O’Sullivan, E. P., Woodall, N. M., & Ahmad, I. (2015) · British Journal of Anaesthesia · doi:10.1093/bja/aev371 · Cited by 2,214
Self-citationGuidelines for the management of tracheal intubation in critically ill adults
Higgs, A., McGrath, B. A., Goddard, C., Rangasami, J., Suntharalingam, G., Gale, R., & Cook, T. M. (2018) · British Journal of Anaesthesia · doi:10.1016/j.bja.2017.10.021 · Cited by 900
Mushambi, M. C., Kinsella, S. M., Popat, M., Swales, H., Ramaswamy, K. K., Winton, A. L., & Quinn, A. C. (2015) · Anaesthesia · doi:10.1111/anae.13260 · Cited by 608
Preoxygenation: physiologic basis, benefits, and potential risks
Nimmagadda, U., Salem, M. R., & Crystal, G. J. (2017) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000001589 · Cited by 404
Yao, W., Wang, T., Jiang, B., Gao, F., Wang, L., Zheng, H., Xiao, W., Yao, S., Mei, W., Chen, X., et al. (2020) · British Journal of Anaesthesia · doi:10.1016/j.bja.2020.03.026 · Cited by 354
Self-citationMyatra, S. N., Shah, A., Kundra, P., Patwa, A., Ramkumar, V., Divatia, J. V., Raveendra, U. S., Shetty, S. R., Ahmed, S. M., Doctor, J. R., et al. (2016) · Indian Journal of Anaesthesia · doi:10.4103/0019-5049.195481 · Cited by 294
Mir, F., Patel, A., Iqbal, R., Cecconi, M., & Nouraei, S. A. R. (2017) · Anaesthesia · doi:10.1111/anae.13799 · Cited by 290
Self-citationHigh-flow nasal oxygen therapy in intensive care and anaesthesia
Renda, T., Corrado, A., Iskandar, G., Pelaia, G., Abdalla, K., & Navalesi, P. (2018) · British Journal of Anaesthesia · doi:10.1016/j.bja.2017.11.010 · Cited by 280
The Physiologically Difficult Airway
Mosier, J., Joshi, R., Hypes, C., Pacheco, G., Valenzuela, T., & Sakles, J. (2015) · Western Journal of Emergency Medicine · doi:10.5811/westjem.2015.8.27467 · Cited by 265
Wong, D. T., Yee, A. J., Leong, S. M., & Chung, F. (2017) · Canadian Journal of Anesthesia/Journal canadien d'anesthésie · doi:10.1007/s12630-016-0802-z · Cited by 89
Airway management in the critically ill: the same, but different
Higgs, A., Cook, T. M., & McGrath, B. A. (2016) · British Journal of Anaesthesia · doi:10.1093/bja/aew055 · Cited by 54
“This has enabled difficult airway management to be carried out unhurriedly, or even obviated the need to secure the airway during surgery.(22) However its effectiveness in preventing or delaying hypoxia during airway management in the critically ill is 2 | Editorial”
Limitations of videolaryngoscopy
Norris, A., & Heidegger, T. (2016) · British Journal of Anaesthesia · doi:10.1093/bja/aew122 · Cited by 38
Metadata
- Authors
- Patel, A., & Nouraei, S. A. R.
- Venue
- Anaesthesia
- Publisher
- Wiley
- Published
- 2014-11-10
- Volume
- 70
- Issue
- 3
- Pages
- 323-329
- ISSN
- 0003-2409 (ISSN-L)
- 1365-2044
- OpenAlex
- W2041921583
- Cited by
- 825
- References
- 33
- FWCI
- 61.12
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.