Cuffed vs. uncuffed tracheal tubes in children: a randomised controlled trial comparing leak, tidal volume and complications

Chambers, N. A., Ramgolam, A., Sommerfield, D., Zhang, G., Ledowski, T., Thurm, M., Lethbridge, M., Hegarty, M., von Ungern‐Sternberg, B. S. · 2018 · Anaesthesia
Cited by 171

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

Summary: Cuffed tracheal tubes are increasingly used in paediatric anaesthetic practice. This study compared tidal volume and leakage around cuffed and uncuffed tracheal tubes in children who required standardised mechanical ventilation of their lungs in the operating theatre. Children (0–16 years) undergoing elective surgery requiring tracheal intubation were randomly assigned to receive either a cuffed or an uncuffed tracheal tube. Assessments were made at five different time‐points: during volume‐controlled ventilation 6 ml.kg −1 , PEEP 5 cmH 2 O and during pressure‐controlled ventilation 10 cmH 2 O / PEEP 5 cmH 2 O. The pressure‐controlled ventilation measurement time‐points were: just before a standardised recruitment manoeuvre; just after recruitment manoeuvre; 10 min; and 30 min after the recruitment manoeuvre. Problems and complications were recorded. During volume‐controlled ventilation, leakage was significantly less with cuffed tracheal tubes than with uncuffed tracheal tubes; in ml.kg −1 , median (IQR [range]) 0.20 (0.13–0.39 [0.04–0.60]) vs. 0.82 (0.58–1.38 [0.24–4.85]), respectively, p < 0.001. With pressure‐controlled ventilation, leakage was less with cuffed tracheal tubes and stayed unchanged over a 30‐min period, whereas with uncuffed tracheal tubes, leakage was higher and increased further over the 30‐min period. Tidal volumes were higher in the cuffed group and increased over time, but in the uncuffed group were lower and decreased over time. Both groups showed an increase in tidal volumes following recruitment manoeuvres. There were more short‐term complications with uncuffed tracheal tubes, but no major complications were recorded in either group at long‐term follow‐up. With standardised ventilator settings, cuffed tracheal tubes produced better ventilation characteristics compared with uncuffed tracheal tubes during general anaesthesia for routine elective surgery.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/anae.14113

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 171

Metadata

Authors
Chambers, N. A., Ramgolam, A., Sommerfield, D., Zhang, G., Ledowski, T., Thurm, M., Lethbridge, M., Hegarty, M., & von Ungern‐Sternberg, B. S.
Venue
Anaesthesia
Publisher
Wiley
Published
2017-11-23
Volume
73
Issue
2
Pages
160-168
ISSN
  • 0003-2409 (ISSN-L)
  • 1365-2044
OpenAlex
W2769002019
Cited by
171
References
5
FWCI
42.12
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Cuffed vs. uncuffed tracheal tubes in children: a randomised controlled trial comparing leak, tidal volume and complications. https://app.cochat.ai/papers/10.1111/anae.14113
The paper
Chambers, N. A., Ramgolam, A., Sommerfield, D., Zhang, G., Ledowski, T., Thurm, M., Lethbridge, M., Hegarty, M., & von Ungern‐Sternberg, B. S. (2018). Cuffed vs. uncuffed tracheal tubes in children: a randomised controlled trial comparing leak, tidal volume and complications. Anaesthesia. https://doi.org/10.1111/anae.14113

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.