The aerosol box for intubation in coronavirus disease 2019 patients: an in‐situ simulation crossover study
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
The coronavirus disease 2019 pandemic has led to the manufacturing of novel devices to protect clinicians from the risk of transmission, including the aerosol box for use during tracheal intubation. We evaluated the impact of two aerosol boxes (an early‐generation box and a latest‐generation box) on intubations in patients with severe coronavirus disease 2019 with an in‐situ simulation crossover study. The simulated process complied with the Safe Airway Society coronavirus disease 2019 airway management guidelines. The primary outcome was intubation time; secondary outcomes included first‐pass success and breaches to personal protective equipment. All intubations were performed by specialist (consultant) anaesthetists and video recorded. Twelve anaesthetists performed 36 intubations. Intubation time with no aerosol box was significantly shorter than with the early‐generation box (median (IQR [range]) 42.9 (32.9–46.9 [30.9–57.6])s vs. 82.1 (45.1–98.3 [30.8–180.0])s p = 0.002) and the latest‐generation box (52.4 (43.1–70.3 [35.7–169.2])s, p = 0.008). No intubations without a box took more than 1 min, whereas 14 (58%) intubations with a box took over 1 min and 4 (17%) took over 2 min (including one failure). Without an aerosol box, all anaesthetists obtained first‐pass success. With the early‐generation and latest‐generation boxes, 9 (75%) and 10 (83%) participants obtained first‐pass success, respectively. One breach of personal protective equipment occurred using the early‐generation box and seven breaches occurred using the latest‐generation box. Aerosol boxes may increase intubation times and therefore expose patients to the risk of hypoxia. They may cause damage to conventional personal protective equipment and therefore place clinicians at risk of infection. Further research is required before these devices can be considered safe for clinical use.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Aerosol and surface stability of SARS-CoV-2 as compared with SARS-CoV-1
van Doremalen, N., Bushmaker, T., Morris, D. H., Holbrook, M. G., Gamble, A., Williamson, B. N., Tamin, A., Harcourt, J. L., Thornburg, N. J., Gerber, S. I., et al. (2020) · New England Journal of Medicine · doi:10.1056/nejmc2004973 · Cited by 9,951 · cited 1×
“SARS-CoV-2, which causes coronavirus disease 2019 (COVID-19), is predominantly spread by droplets but has the potential for aerosol transmission [5].”
BackgroundFrerk, C., Mitchell, V. S., McNarry, A. F., Mendonca, C., Bhagrath, R., Patel, A., O’Sullivan, E. P., Woodall, N. M., & Ahmad, I. (2015) · British Journal of Anaesthesia · doi:10.1093/bja/aev371 · Cited by 2,214 · cited 1×
“Cognitive overload is recognised to impair decision making and lead to potential patient harm during airway management [29,30].”
BackgroundShanafelt, T., Ripp, J., & Trockel, M. (2020) · JAMA · doi:10.1001/jama.2020.5893 · Cited by 1,956 · cited 1×
“Introduction The severe acute respiratory syndrome-coronavirus-2 (SARS-CoV-2) pandemic has put the lives of healthcare workers at great risk, as evidenced by the growing numbers of healthcare worker deaths inmany nations [1,2].”
Background
Metadata
- Authors
- Begley, J. L., Lavery, K. E., Nickson, C. P., & Brewster, D. J.
- Venue
- Anaesthesia
- Publisher
- Wiley
- Published
- 2020-06
- Volume
- 75
- Issue
- 8
- Pages
- 1014-1021
- ISSN
- 0003-2409 (ISSN-L)
- 1365-2044
- OpenAlex
- W3025934939
- Cited by
- 232
- References
- 3
- FWCI
- 59.48
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The aerosol box for intubation in coronavirus disease 2019 patients: an in‐situ simulation crossover study. https://app.cochat.ai/papers/10.1111/anae.15115
- The paper
- Begley, J. L., Lavery, K. E., Nickson, C. P., & Brewster, D. J. (2020). The aerosol box for intubation in coronavirus disease 2019 patients: an in‐situ simulation crossover study. Anaesthesia. https://doi.org/10.1111/anae.15115
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.