Cited by 51Ocular Surface and Contact LensCorneal surgery and disordersOphthalmology and Visual Impairment Studies

Effect of overnight wear of the Triggerfish® sensor on corneal thickness measured by Visante® anterior segment optical coherence tomography

Hubanova, Ralitsa, Aptel, Florent, Chiquet, Christophe, Mottet, Benjamin, Romanet, Jean‐Paul·2014·Acta Ophthalmologica

Abstract

Purpose: To evaluate the effect of overnight wear of the Triggerfish® contact lens sensor (CLS) on central corneal thickness (CCT) using the V isante® anterior segment optical coherence tomography (AS‐OCT). Methods: Twelve healthy subjects were studied in a sleep laboratory. An ophthalmic examination including ultrasonic CCT, corneal topography, specular microscopy and AS‐OCT CCT was performed. Starting at 7 pm, the Triggerfish® CLS was fitted on one randomly selected eye. Similar AS‐OCT measurements were taken on both eyes every 2 hr from 8 pm to 8 am. The CLS was removed just after the 8 am measurement session. Measurements were repeated at 9 am. Results: Twenty‐four eyes of 12 subjects were studied (mean age, 22.1 ± 2.4 years; four men/eight women). CCT significantly increased during the night in both CLS and control eyes (p < 0.01). The maximal change was +4.4 ± 1.7% in the CLS eyes and +2.9 ± 1.8% in the control eyes (p < 0.05). Throughout the night, CCT significantly increased more in eyes with CLS than in control eyes (p < 0.05). There were significantly more corneal curvature irregularities after overnight wear of the CLS than in the control eye: +1.63 Dioptre (D) versus −0.02 D in the 3‐mm central zone and +3.17 D versus +0.01 D in the 5‐mm central zone (p < 0.01). Conclusion: CCT and corneal curvature irregularities increased slightly but significantly more in eyes with the Triggerfish® CLS than in control eyes during overnight wear. Further studies are required to determine whether the corneal curvature changes modify the signal recorded by the sensor.

Integrity signals

Registry

Crossref · 10.1111/aos.12241

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • The utilization of gold electrodes featuring 3D pillars increased the surface area (300%) as compared to 2D geometries to achieve a sensitivity of 40 × 10−6 m in vivo.

    “The utilization of gold electrodes featuring 3D pillars increased the surface area (300%) as compared to 2D geometries to achieve a sensitivity of 40 × 10−6 m in vivo.63”

    From Wearables in Medicine (2018) · cites this paper as [63]

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Hubanova, R., Aptel, F., Chiquet, C., Mottet, B., & Romanet, J.
Affiliations
  • Université Joseph Fourier (FR)
  • Inserm (FR)
Corresponding author
Aptel, Florent
Venue
Acta Ophthalmologica
Publisher
Wiley
Published
2013-07-15
Volume
92
Issue
2
Pages
e119-23
ISSN
  • 0001-639X (ISSN-L)
  • 1755-375X
  • 1755-3768
OpenAlex
W2042157330
Cited by
51
References
1
Citations by year
2025: 3 · 2024: 1 · 2023: 4 · 2022: 4 · 2021: 1 · 2020: 8 · 2019: 5 · 2018: 5 · 2017: 2 · 2016: 5 · 2015: 7 · 2014: 6
FWCI
6.14
Type
journal article
Language
en
Open access
closed
Locations
  • Acta Ophthalmologica (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Ocular Surface and Contact Lens
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Corneal surgery and disorders
  • Health Sciences › Medicine › Epidemiology › Ophthalmology and Visual Impairment Studies
Keywords
overnight contact lens wear, central corneal thickness, anterior segment optical coherence tomography, corneal hydration
MeSH terms
Adult, Cell Count, Contact Lenses, Hydrophilic, Cornea, Endothelium, Corneal, Female, Humans, Male, Prospective Studies, Telemetry, Anatomy, Cross-Sectional, Corneal Topography, Tomography, Optical Coherence, Young Adult

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review