Accuracy of tympanic and forehead thermometers in private paediatric practice
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Aim: To compare infrared tympanic and infrared contact forehead thermometer measurements with traditional rectal digital thermometers. Methods: A total of 254 children (137 girls) aged one to 24 months (median 7 months) consulting a private paediatric practice because of fever were prospectively recruited. Body temperature was measured using the three different devices. Results: The median and interquartile range for rectal, tympanic and forehead thermometers were 37.6 (37.1–38.4)°C, 37.5 (37.0–38.1)°C and 37.5 (37.1–37.9)°C, respectively (p < 0.01). The limits of agreement in the B land‐A ltman plots were −0.73 to +1.04°C for the tympanic thermometer and −1.18 to +1.64°C for the forehead thermometer. The specificity of both the tympanic and forehead thermometers for detecting fever above 38°C was good, but sensitivity was low. Forehead measurements were susceptible to the use of a radiant warmer. Conclusion: Both the tympanic and forehead devices recorded lower temperatures than the rectal thermometers. The limits of agreement were particularly wide for the forehead thermometer and considerable for the tympanic thermometer. In the absence of valid alternatives, because of the ease to use and little degree of discomfort, tympanic thermometers can still be used with some reservations. Forehead thermometers should not be used in paediatric practice.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Richardson, M., & Lakhanpaul, M. (2007) · BMJ · doi:10.1136/bmj.39218.495255.ae · Cited by 120
Research works printed but not linked: 19
- Diethelm M, 1986, Prospektive Studie über die Tätigkeit des praktizierenden Kinderarztes – II. Besuchsgründe und Diagnosen, Helv Paediatr Acta, 41, 29
- 10.1016/j.clinthera.2009.08.006 · DOI
- 10.1136/adc.2010.185801 · DOI · Paper page
- 10.1016/S0140-6736(02)09783-0 · DOI · Paper page
- Freed GL, 1992, Lack of agreement of tympanic membrane temperature assessments with conventional methods in a private practice setting, Pediatrics, 89, 384, 10.1542/peds.89.3.384 · doi:10.1542/peds.89.3.384
- 10.1136/adc.2006.114314 · DOI
- 10.1111/j.1365-2702.2010.03565.x · DOI · Paper page
- 10.1016/S0733-8627(03)00051-8 · doi:10.1016/s0733-8627(03)00051-8
- 10.1097/ALN.0b013e31823d7784 · DOI · Paper page
- 10.1016/j.aenj.2008.05.003 · DOI
- 10.1111/j.1742-6723.2006.00847.x · DOI
- 10.1016/S0196-0644(95)70350-0 · DOI
- Fadzil FM, 2010, A comparative study on the accuracy of noninvasive thermometers, Aust Fam Physician, 39, 237
- 10.1001/archpedi.1996.02170260078013 · DOI
- 10.1186/1824-7288-37-8 · DOI
- 10.1016/j.clinthera.2012.06.011 · DOI
- 10.1097/PEC.0b013e31827b5427 · DOI · Paper page
- 10.1111/j.1365-2125.2012.04311.x · DOI
- 10.1016/S0022-3476(70)80281-5 · doi:10.1016/s0022-3476(70)80281-5
Cited by
Niven, D. J., Gaudet, J. E., Laupland, K. B., Mrklas, K. J., Roberts, D. J., & Stelfox, H. T. (2015) · Annals of Internal Medicine · doi:10.7326/m15-1150 · Cited by 240
Circadian rhythmicity of body temperature and metabolism
Refinetti, R. (2020) · Temperature · doi:10.1080/23328940.2020.1743605 · Cited by 155
“[304] Teller J, Ragazzi M, Simonetti GD, et al.”
Background2016 Update of the Italian Pediatric Society Guidelines for Management of Fever in Children
Chiappini, E., Venturini, E., Remaschi, G., Principi, N., Longhi, R., Tovo, P.-A., Becherucci, P., Bonsignori, F., Esposito, S., Festini, F., et al. (2017) · The Journal of Pediatrics · doi:10.1016/j.jpeds.2016.09.043 · Cited by 104
Pecoraro, V., Petri, D., Costantino, G., Squizzato, A., Moja, L., Virgili, G., & Lucenteforte, E. (2021) · Internal and Emergency Medicine · doi:10.1007/s11739-020-02556-0 · Cited by 49
“Teller 2014 [64] Cross-sectional Private pediatric practice Children 254 Rectal, digital Tympanic, infrared Forehead, infrared”
Metadata
- Authors
- Teller, J., Ragazzi, M., Simonetti, G., & Lava, S.
- Venue
- Acta Paediatrica
- Publisher
- Wiley
- Published
- 2013-11-18
- Volume
- 103
- Issue
- 2
- Pages
- e80-3
- ISSN
- 0365-1436 (ISSN-L)
- 0803-5253
- 1651-2227
- OpenAlex
- W2019780896
- Cited by
- 42
- References
- 1
- FWCI
- 2.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.