Reduction in central venous pressure enhances erythropoietin synthesis: role of volume‐regulating hormones
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Aims: Erythropoiesis is a tightly controlled biological event, but its regulation under non‐hypoxic conditions, however, remains unresolved. We examined whether acute changes in central venous blood pressure (CVP) elicited by whole‐body tilting affect erythropoietin (EPO) concentration according to volume‐regulating hormones. Methods: Plasma EPO, angiotensin II (ANGII), aldosterone, pro‐atrial natriuretic peptide (pro ANP) and copeptin concentrations were measured at supine rest and up to 3 h during 30° head‐up (HUT) and head‐down tilt (HDT) in ten healthy male volunteers. Plasma albumin concentration was used to correct for changes in plasma volume and CVP was estimated through the internal jugular vein (IJV) aspect ratio with ultrasonography. Results: From supine rest, the IJV aspect ratio was decreased and increased throughout HUT and HDT respectively. Plasma EPO concentration increased during HUT (13%; P = 0.001, P for linear component = 0.017), independent of changes in albumin concentration. Moreover, ANGII and copeptin concentrations increased during HUT, while pro ANP decreased. The increase in EPO concentration during HUT disappeared when adjusted for changes in copeptin. During HDT, EPO, ANGII and copeptin concentrations remained unaffected while pro ANP increased. In regression analyses, EPO was positively associated with copeptin (β = 0.55; 95% CI = 0.18, 0.93; P = 0.004) irrespective of changes in other hormones and albumin concentration. Conclusion: Reduction in CVP prompts an increase in plasma EPO concentration independent of hemoconcentration and hence suggests CVP per se as an acute regulator of EPO synthesis. This effect may be explained by changes in volume‐regulating hormones.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Balanescu, S., Kopp, P., Gaskill, M. B., Morgenthaler, N. G., Schindler, C., & Rutishauser, J. (2011) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2010-2499 · Cited by 246 · cited 2×
“Given the strong correlation between copeptin and VPN, copeptin is commonly used as a marker for VPN in clinical and research settings (Khan et al. 2007, Morgenthaler et al. 2008, Balanescu et al. 2011, Roussel et al. 2014).”
MethodThe regulation of antidiuretic hormone release in man
Segar, W. E., & Moore, W. W. (1968) · Journal of Clinical Investigation · doi:10.1172/jci105900 · Cited by 155
Cited by
Biology of VO2max: looking under the physiology lamp
Lundby, C., Montero, D., & Joyner, M. (2017) · Acta Physiologica · doi:10.1111/apha.12827 · Cited by 300
Self-citationTobacco smoking: A stimulus for blood volume expansion
Sotiridis, A., Dardamanis-Aidonas, C., Makris, A., Loukas, I., Geladas, N., & Koskolou, M. (2026) · Respiratory Physiology & Neurobiology · doi:10.1016/j.resp.2025.104505 · Cited by 1
Metadata
- Authors
- Montero, D., Rauber, S., Goetze, J. P., & Lundby, C.
- Venue
- Acta Physiologica
- Publisher
- Wiley
- Published
- 2016-06
- Volume
- 218
- Issue
- 2
- Pages
- 89-97
- ISSN
- 1748-1708 (ISSN-L)
- 1748-1716
- OpenAlex
- W2383313986
- Cited by
- 44
- References
- 2
- FWCI
- 3.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.