The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Systematic review with meta-analysis: the diagnostic accuracy of transient elastography for the staging of liver fibrosis in patients with chronic hepatitis B
Open accessAbstract
BACKGROUND: Transient elastography is a non-invasive method for staging liver fibrosis. The meta-analysis using the hierarchical models to evaluate the diagnostic accuracy of transient elastography for the staging of liver fibrosis in patients with chronic hepatitis B was rarely reported. AIM: A meta-analysis using the hierarchical models was performed to assess transient elastography for diagnosing and stage liver fibrosis in patients with chronic hepatitis B. METHODS: Electronic databases were searched and studies were identified to assess the diagnostic accuracy of transient elastography in CHB patients for staging fibrosis F ≥ 2, F ≥ 3 and F = 4 with liver biopsy as a reference standard. The hierarchical summary receiver operating characteristic curve and the bivariate models were performed to evaluate the diagnostic accuracy of transient elastography, and meta-regression analyses were performed to explore the heterogeneity. The quality Assessment of Diagnostic Accuracy Studies-2 tool was used to assess the quality of studies. RESULTS: Twenty-seven studies with a total of 4386 patients were included in the meta-analysis. The summary sensitivity of transient elastography for staging fibrosis F ≥ 2, F ≥ 3 and F = 4 was 0.806 (95% CI, 0.756-0.847), 0.819 (95% CI, 0.748-0.874) and 0.863 (95% CI, 0.818-0.898), respectively, and the summary specificity was 0.824 (95% CI, 0.761-0.873), 0.866 (95% CI, 0.824-0.899) and 0.875 (95% CI, 0.840-0.903), respectively. The corresponding area under the summary receiver operating characteristic curve was 0.88 (95% CI, 0.85-0.91), 0.91 (95% CI, 0.88-0.93) and 0.93 (95% CI, 0.91-0.95), respectively. Meta-regression showed that patient age contributed to heterogeneity. CONCLUSIONS: Transient elastography performs well to diagnose liver fibrosis in patients with chronic hepatitis B, which may reduce the use of liver biopsy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., Mallett, S., Deeks, J. J., Reitsma, J. B., Leeflang, M. M. G., Sterne, J. A. C., Bossuyt, P. M. M., & the QUADAS-2 Group* (2011) · Annals of Internal Medicine · doi:10.7326/0003-4819-155-8-201110180-00009 · Cited by 14,199
metandi: Meta-analysis of diagnostic accuracy using hierarchical logistic regression
Harbord, R. M., & Whiting, P. (2009) · The Stata Journal: Promoting communications on statistics and Stata · doi:10.1177/1536867x0900900203 · Cited by 453
Cited by
EASL 2017 Clinical Practice Guidelines on the management of hepatitis B virus infection
Lampertico, P., Agarwal, K., Berg, T., Buti, M., Janssen, H. L. A., Papatheodoridis, G., Zoulim, F., & Tacke, F. (2017) · Journal of Hepatology · doi:10.1016/j.jhep.2017.03.021 · Cited by 5,391
Dietrich, C., Bamber, J., Berzigotti, A., Bota, S., Cantisani, V., Castera, L., Cosgrove, D., Ferraioli, G., Friedrich-Rust, M., Gilja, O., et al. (2017) · Ultraschall in der Medizin - European Journal of Ultrasound · doi:10.1055/s-0043-103952 · Cited by 1,011
Chronic Hepatitis B Infection: A Review
Tang, L. S. Y., Covert, E., Wilson, E., & Kottilil, S. (2018) · JAMA · doi:10.1001/jama.2018.3795 · Cited by 657
EASL Clinical Practice Guidelines on the management of hepatitis B virus infection
Cornberg, M., Sandmann, L., Jaroszewicz, J., Kennedy, P., Lampertico, P., Lemoine, M., Lens, S., Testoni, B., Lai-Hung Wong, G., & Russo, F. P. (2025) · Journal of Hepatology · doi:10.1016/j.jhep.2025.03.018 · Cited by 437
Principles of ultrasound elastography
Ozturk, A., Grajo, J. R., Dhyani, M., Anthony, B. W., & Samir, A. E. (2018) · Abdominal Radiology · doi:10.1007/s00261-018-1475-6 · Cited by 299
Metadata
- Authors
- Li, Y., Huang, Y.-S., Wang, Z.-Z., Yang, Z.-R., Sun, F., Zhan, S.-Y., Liu, X.-E., & Zhuang, H.
- Venue
- Alimentary Pharmacology & Therapeutics
- Publisher
- Wiley
- Published
- 2015-12-15
- Volume
- 43
- Issue
- 4
- Pages
- 458-469
- ISSN
- 0269-2813 (ISSN-L)
- OpenAlex
- W2205525005
- Cited by
- 161
- References
- 2
- FWCI
- 1.70
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Systematic review with meta-analysis: the diagnostic accuracy of transient elastography for the staging of liver fibrosis in patients with chronic hepatitis B. https://app.cochat.ai/papers/10.1111/apt.13488
- The paper
- Li, Y., Huang, Y.-S., Wang, Z.-Z., Yang, Z.-R., Sun, F., Zhan, S.-Y., Liu, X.-E., & Zhuang, H. (2016). Systematic review with meta-analysis: the diagnostic accuracy of transient elastography for the staging of liver fibrosis in patients with chronic hepatitis B. Alimentary Pharmacology & Therapeutics. https://doi.org/10.1111/apt.13488
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.