CoChat

Volume interpolated 3 D‐spoiled gradient echo sequence is better than dynamic contrast spin echo sequence for MRI detection of corticotropin secreting pituitary microadenomas

Kasaliwal, Rajeev, Sankhe, Shilpa S., Lila, Anurag R., Budyal, Sweta R., Jagtap, Varsha S., Sarathi, Vijaya, Kakade, Harshal, Bandgar, Tushar, Menon, Padmavathy S., Shah, Nalini S. · 2013 · Clinical Endocrinology
Cited by 63

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Summary: Background: Various techniques have been attempted to increase the yield of magnetic resonance imaging (MRI) for localization of pituitary microadenomas in corticotropin (ACTH)‐dependent C ushing's syndrome (CS). Objective: To compare the performance of dynamic contrast spin echo (DC‐SE) and volume interpolated 3 D‐spoiled gradient echo (VI‐SGE) MR sequences in the diagnostic evaluation of ACTH‐dependent CS. Design: Data was analysed retrospectively from a series of ACTH‐dependent CS patients treated over 2‐year period at a tertiary care referral centre (2009–2011). Patients: Thirty‐six patients (24 female and 12 male) were diagnosed to have ACTH‐dependent CS during the study period. All patients underwent MRI by both sequences during a single examination. Cases with negative and equivocal pituitary MR imaging underwent corticotropin‐releasing hormone (CRH) stimulated bilateral inferior petrosal sinus sampling (BIPSS) to confirm pituitary origin of ACTH excess state. Thirty patients were finally diagnosed to have Cushing's disease (CD) [based on histopathology proof of adenoma and/or remission (partial/complete) of hypercortisolism postsurgery]. Six patients were diagnosed to have histopathologically proven ectopic CS. Results: Of 30 patients with CD, 24 patients had microadenomas and 6 patients had macroadenomas. DC‐SE MRI sequence was able to identify microadenomas in 16 of 24 patients, whereas postcontrast VI‐SGE sequence was able to identify microadenomas in 21 of 24 patients. All six patients of ectopic CS had negative pituitary MR imaging by both techniques (specificity: 100%). Conclusion: VI‐SGE MR sequence was better for localization of pituitary microadenomas particularly when DC‐SE MR sequence is negative or equivocal and should be used in addition to DC‐SE MR sequence for the evaluation of ACTH‐dependent CS.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/cen.12069

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 63

Metadata

Authors
Kasaliwal, R., Sankhe, S. S., Lila, A. R., Budyal, S. R., Jagtap, V. S., Sarathi, V., Kakade, H., Bandgar, T., Menon, P. S., & Shah, N. S.
Venue
Clinical Endocrinology
Publisher
Wiley
Published
2013-04-06
Volume
78
Issue
6
Pages
825-830
ISSN
  • 0300-0664 (ISSN-L)
  • 1365-2265
OpenAlex
W2093236226
Cited by
63
References
1
FWCI
2.30
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.