Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 343

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Micropulse versus continuous wave transscleral diode cyclophotocoagulation in refractory glaucoma: a randomized exploratory study

Aquino, Maria Cecilia D, Barton, Keith, Tan, Anna Marie WT, Sng, Chelvin, Li, Xiang, Loon, Seng Chee, Chew, Paul TK · 2015 · Clinical & Experimental Ophthalmology

Abstract

Background: The aim of this study was to compare the efficacy and safety of micropulse and continuous wave diode transscleral cyclophotocoagulation in refractory glaucoma. Design: Randomized, comparative, exploratory study in a tertiary hospital setting. Participants: Patients with refractory, end‐stage glaucoma. Methods: Forty‐eight patients were randomized to either treatment. The intraocular pressure, visual acuity, number of medicines and repeat treatment were monitored for 18 months. Complications that include visual acuity decline, prolonged anterior chamber inflammation, phthisis bulbi, scleral thinning and ocular pain were noted. Main Outcome Measure: Intraocular pressure between 6 and 21 mmHg and at least a 30% reduction with or without anti‐glaucoma medications after 18 months. Results: A successful primary outcome was achieved in 75% of patients who underwent micropulse cyclophotocoagulation and 29% of patients who received continuous wave cyclophotocoagulation after 12 months (P < 0.01). At 18 months, successful outcome was 52% and 30% (P = 0.13), respectively. The mean intraocular pressure was reduced by 45% in both groups (P = 0.70) from a baseline of 36.5 mmHg and 35.0 mmHg (P = 0.50) after 17.5 ± 1.6 months (range 16–19) follow up. No significant difference in retreatment rates or number of intraocular pressure lowering medications was noted. The ocular complication rate was higher in continuous wave treated eyes (P = 0.01). Conclusion: Diode transscleral cyclophotocoagulation in both micropulse and continuous modes was effective in lowering intraocular pressure. The micropulse mode provided a more consistent and predictable effect in lowering intraocular pressure with minimal ocular complications.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/ceo.12360

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 343

Metadata

Authors
Aquino, M. C. D., Barton, K., Tan, A. M. W., Sng, C., Li, X., Loon, S. C., & Chew, P. T.
Venue
Clinical & Experimental Ophthalmology
Publisher
Wiley
Published
2014-06-21
Volume
43
Issue
1
Pages
40-46
ISSN
  • 1442-6404 (ISSN-L)
  • 1442-9071
OpenAlex
W1564636510
Cited by
343
References
1
FWCI
5.13
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.