A Novel Approach to Monitoring Pulmonary Congestion in Heart Failure: Initial Animal and Clinical Experiences Using Remote Dielectric Sensing Technology
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Despite current therapies and disease management approaches, rates of heart failure (HF) rehospitalization remain high. New tools are needed to assess preclinical (asymptomatic) pulmonary congestion to enable outpatient management. Hence, a novel monitoring system based on noninvasive remote dielectric sensing (R e DS) technology was developed. Validation of the R e DS technology was conducted in preclinical and clinical studies. In a porcine HF model, acute fluid overload followed by administration of diuretics were performed. Changes in R e DS values were correlated to serial computed tomographic (CT) assessments of lung fluid concentrations. In hospitalized decompensated HF patients, changes in R e DS values were correlated to net fluid balance changes. A nearly linear pattern between the changes in R e DS and CT fluid concentration values was observed in 6 discrete experiments (I ntraclass correlation=0.95). Results from 24 patients demonstrated a reduction in R e DS values of 17.53%±11% throughout hospitalization, consistent with a reduction in pulmonary congestion. This finding strongly correlated with changes in net fluid balance (P earson correlation=0.86; 95% c onfidence i nterval, 0.68–0.94; R2=0.74). These findings suggest that R e DS technology accurately quantifies lung fluid concentration and has potential for monitoring HF patients through hospitalization and possibly at home.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rehospitalizations among Patients in the Medicare Fee-for-Service Program
Jencks, S. F., Williams, M. V., & Coleman, E. A. (2009) · New England Journal of Medicine · doi:10.1056/nejmsa0803563 · Cited by 5,164
Abraham, W. T., Adamson, P. B., Bourge, R. C., Aaron, M. F., Costanzo, M. R., Stevenson, L. W., Strickland, W., Neelagaru, S., Raval, N., Krueger, S., et al. (2011) · The Lancet · doi:10.1016/s0140-6736(11)60101-3 · Cited by 1,744
Self-citationTelemonitoring in patients with heart failure
Chaudhry, S. I., Mattera, J. A., Curtis, J. P., Spertus, J. A., Herrin, J., Lin, Z., Phillips, C. O., Hodshon, B. V., Cooper, L. S., & Krumholz, H. M. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa1010029 · Cited by 1,232
Koehler, F., Winkler, S., Schieber, M., Sechtem, U., Stangl, K., Böhm, M., Boll, H., Baumann, G., Honold, M., Koehler, K., et al. (2011) · Circulation · doi:10.1161/circulationaha.111.018473 · Cited by 716
Cited by
Self-powered cardiovascular electronic devices and systems
Zheng, Q., Tang, Q., Wang, Z. L., & Li, Z. (2021) · Nature Reviews Cardiology · doi:10.1038/s41569-020-0426-4 · Cited by 348
The role of wearables in heart failure
Singhal, A., & Cowie, M. R. (2020) · Current Heart Failure Reports · doi:10.1007/s11897-020-00467-x · Cited by 85
Hemodynamic monitoring in the era of digital health
Michard, F. (2016) · Annals of Intensive Care · doi:10.1186/s13613-016-0119-7 · Cited by 57
Metadata
- Authors
- Amir, O., Rappaport, D., Zafrir, B., & Abraham, W. T.
- Venue
- Congestive Heart Failure
- Publisher
- Wiley
- Published
- 2013-01-25
- Volume
- 19
- Issue
- 3
- Pages
- 149-155
- ISSN
- 1527-5299 (ISSN-L)
- 1751-7133
- OpenAlex
- W2024256594
- Cited by
- 96
- References
- 4
- FWCI
- 1.69
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.