Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 182

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Long‐Term Outcomes of Dental Implants with a Titanium Plasma‐Sprayed Surface: A 20‐Year Prospective Case Series Study in Partially Edentulous Patients

Chappuis, Vivianne, Buser, Ramona, Brägger, Urs, Bornstein, Michael M., Salvi, Giovanni E., Buser, Daniel·2013·Clinical Implant Dentistry and Related Research

Abstract

Background: Long‐term studies of ≥10 years are important milestones to get a better understanding of potential factors causing implant failures or complications. Purpose: The present study investigated the long‐term outcomes of titanium dental implants with a rough, microporous surface (titanium plasma sprayed [TPS]) and the associated biologic and technical complications in partially edentulous patients with fixed dental prostheses over a 20‐year follow‐up period. Materials and Methods: Sixty‐seven patients, who received 95 implants in the 1980s, were examined with well‐established clinical and radiographic parameters. Based on these findings, each implant was classified as either successful, surviving, or failed. Results: Ten implants in nine patients were lost during the observation period, resulting in an implant survival rate of 89.5%. Radiographically, 92% of the implants exhibited crestal bone loss below 1 mm between the 1‐ and 20‐year follow‐up examinations. Only 8% yielded peri‐implant bone loss of >1 mm and none exhibited severe bone loss of more than 1.8 mm. During the observation period, 19 implants (20%) experienced a biologic complication with suppuration. Of these 19 implants, 13 implants (13.7%) had been treated and were successfully maintained over the 20‐year follow‐up period. Therefore, the 20‐year implant success rate was 75.8 or 89.5% depending on the different success criteria. Technical complications were observed in 32%. Conclusion: The present study is the first to report satisfactory success rates after 20 years of function of dental implants with a TPS surface in partially edentulous patients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/cid.12056

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 182

Metadata

Authors
Chappuis, V., Buser, R., Brägger, U., Bornstein, M. M., Salvi, G. E., & Buser, D.
Venue
Clinical Implant Dentistry and Related Research
Publisher
Wiley
Published
2013-03-18
Volume
15
Issue
6
Pages
780-790
ISSN
  • 1523-0899 (ISSN-L)
  • 1708-8208
OpenAlex
W1943236961
Cited by
182
References
1
FWCI
12.89
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Long‐Term Outcomes of Dental Implants with a Titanium Plasma‐Sprayed Surface: A 20‐Year Prospective Case Series Study in Partially Edentulous Patients. https://app.cochat.ai/papers/10.1111/cid.12056
The paper
Chappuis, V., Buser, R., Brägger, U., Bornstein, M. M., Salvi, G. E., & Buser, D. (2013). Long‐Term Outcomes of Dental Implants with a Titanium Plasma‐Sprayed Surface: A 20‐Year Prospective Case Series Study in Partially Edentulous Patients. Clinical Implant Dentistry and Related Research. https://doi.org/10.1111/cid.12056

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.