Dental implants‐associated release of titanium particles: A systematic review
The DOI matches its Crossref record; 46 of the 46 references it cites were found in a registry or an index.
Abstract
Objectives: The presence of titanium (Ti) particles around dental implants has been reported in the literature for decades. The prospective presence of Ti debris on soft tissues surrounding dental implants has not been systematically investigated and remains to be explored. Hence, this review aimed to evaluate the origin, presence, characteristics, and location of Ti particles in relation to dental implants. Material and methods: Literature searches were conducted by two reviewers independently based on the PRISMA guidelines. The systematic review identified studies on Ti particles derived from dental implants. We evaluated several parameters, including anatomical location, and the suspected methods of Ti particles release. Results: The search resulted in 141 articles, of which 26 were eligible and included in the systematic review of the literature. The investigations reported Ti and metal‐like particles in the soft (i.e., epithelial cells, connective tissue, and inflammatory cells) and hard (bone crest and bone marrow) tissues around the dental implants. Shape and size of the particles varied. The current literature reported a size range from 100 nm to 54 µm identified by multiple particles identification methods. Conclusion: Ti particles surrounding peri‐implant tissues are a common finding. Peri‐implantitis sites presented a higher number of particles compared to healthy implants. The particles were mostly around the implants and inside epithelial cells, connective tissue, macrophages, and bone. Various mechanisms were described as causes of Ti release, including friction during implant insertion, corrosion of the implant surface, friction at the implant–abutment interface, implantoplasty, and several methods used for implant surface detoxification.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Animal research: Reporting in vivo experiments: The ARRIVE guidelines
Kilkenny, C., Browne, W., Cuthill, I. C., Emerson, M., & Altman, D. G. (2010) · British Journal of Pharmacology · doi:10.1111/j.1476-5381.2010.00872.x · Cited by 3,625
Use of NeuroEyeCoach™ to Improve Eye Movement Efficacy in Patients with Homonymous Visual Field Loss
Sahraie, A., Smania, N., & Zihl, J. (2016) · BioMed Research International · doi:10.1155/2016/5186461 · Cited by 1,772
Peri‐implant health and disease. A systematic review of current epidemiology
Derks, J., & Tomasi, C. (2015) · Journal of Clinical Periodontology · doi:10.1111/jcpe.12334 · Cited by 1,302
Biomedical applications of titanium and its alloys
Elias, C. N., Lima, J. H. C., Valiev, R., & Meyers, M. A. (2008) · JOM · doi:10.1007/s11837-008-0031-1 · Cited by 983
Impact of Dental Implant Surface Modifications on Osseointegration
Smeets, R., Stadlinger, B., Schwarz, F., Beck-Broichsitter, B., Jung, O., Precht, C., Kloss, F., Gröbe, A., Heiland, M., & Ebker, T. (2016) · BioMed Research International · doi:10.1155/2016/6285620 · Cited by 701
Buser, D., Janner, S. F. M., Wittneben, J., Brägger, U., Ramseier, C. A., & Salvi, G. E. (2012) · Clinical Implant Dentistry and Related Research · doi:10.1111/j.1708-8208.2012.00456.x · Cited by 642
Effectiveness of Implant Therapy Analyzed in a Swedish Population: Prevalence of Peri-implantitis
Derks, J., Schaller, D., Håkansson, J., Wennström, J. L., Tomasi, C., & Berglundh, T. (2016) · Journal of Dental Research · doi:10.1177/0022034515608832 · Cited by 611
A reconfigurable analog VLSI neural network architecture with non linear synapses
M., B. G., Stratta, R., Trucco, E., CAVIGLIA, D., & VALLE, M. (1998) · CINECA IRIS Institutial Research Information System (University of Genoa) · doi:10.1002/(sici)1097 · Cited by 576
Abu-Amer, Y., Darwech, I., & Clohisy, J. C. (2007) · Arthritis Research & Therapy · doi:10.1186/ar2170 · Cited by 534
Clinical research on peri‐implant diseases: consensus report of Working Group 4
Sanz, M., Chapple, I. L., & on behalf of Working Group 4 of the VIII European Workshop on Periodontology (2012) · Journal of Clinical Periodontology · doi:10.1111/j.1600-051x.2011.01837.x · Cited by 518
Cited by
General review of titanium toxicity
Kim, K. T., Eo, M. Y., Nguyen, T. T. H., & Kim, S. M. (2019) · International Journal of Implant Dentistry · doi:10.1186/s40729-019-0162-x · Cited by 404
Kotsakis, G. A., & Olmedo, D. G. (2021) · Periodontology 2000 · doi:10.1111/prd.12372 · Cited by 196
Metadata
- Authors
- Suárez‐López del Amo, F., Garaicoa‐Pazmiño, C., Fretwurst, T., Castilho, R. M., & Squarize, C. H.
- Venue
- Clinical Oral Implants Research
- Publisher
- Wiley
- Published
- 2018-10-02
- Volume
- 29
- Issue
- 11
- Pages
- 1085-1100
- ISSN
- 0905-7161 (ISSN-L)
- 1600-0501
- OpenAlex
- W2894553789
- Cited by
- 194
- References
- 46
- FWCI
- 3.88
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Dental implants‐associated release of titanium particles: A systematic review. https://app.cochat.ai/papers/10.1111/clr.13372
- The paper
- Suárez‐López del Amo, F., Garaicoa‐Pazmiño, C., Fretwurst, T., Castilho, R. M., & Squarize, C. H. (2018). Dental implants‐associated release of titanium particles: A systematic review. Clinical Oral Implants Research. https://doi.org/10.1111/clr.13372
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.