The DOI matches its Crossref record; 52 of the 52 references it cites were found in a registry or an index.
General review of titanium toxicity
Open accessAbstract
BACKGROUND: Titanium is a commonly used inert bio-implant material within the medical and dental fields. Although the use of titanium is thought to be safe with a high success rate, in some cases, there are rare reports of problems caused by titanium. In most of these problematic reports, only individual reports are dominant and comprehensive reporting has not been performed. This comprehensive article has been prepared to review the toxicity of titanium materials within the medical and dental fields. METHODS: We used online searching tools including MEDLINE (PubMed), Embase, Cochrane Library, and Google Scholar by combining keywords such as "titanium implant toxicity," "titanium implant corrosion," "titanium implant allergy," and "yellow nail syndrome." Recently updated data has been collected and compiled into one of four categories: "the toxicity of titanium," "the toxicity of titanium alloys," "the toxicity of titanium implants," and "diseases related to titanium." RESULTS: Recent studies with regard to titanium toxicity have been increasing and have now expanded to the medical field in addition to the fields of environmental research and basic science. Problems that may arise in titanium-based dental implants include the generation of titanium and titanium alloy particles and ions deposited into surrounding tissues due to the corrosion and wear of implants, resulting in bone loss due to inflammatory reactions, which may lead to osseointegration failure of the dental implant. These titanium ions and particles are systemically deposited and can lead to toxic reactions in other tissues such as yellow nail syndrome. Additionally, implant failure and allergic reactions can occur due to hypersensitivity reactions. Zirconia implants can be considered as an alternative; however, limitations still exist due to a lack of long-term clinical data. CONCLUSIONS: Clinicians should pay attention to the use of titanium dental implants and need to be aware of the problems that may arise from the use of titanium implants and should be able to diagnose them, in spite of very rare occurrence. Within the limitation of this study, it was suggested that we should be aware the rare problems of titanium toxicity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The long-term efficacy of currently used dental implants: a review and proposed criteria of success.
Albrektsson, T. O., Zarb, G. A., Worthington, P., & Eriksson, A. R. (1986) · PubMed · Cited by 3,691
Titanium dioxide nanoparticles: a review of current toxicological data
Shi, H., Magaye, R., Castranova, V., & Zhao, J. (2013) · Particle and Fibre Toxicology · doi:10.1186/1743-8977-10-15 · Cited by 1,498
WANG, J., ZHOU, G., CHEN, C., YU, H., WANG, T., MA, Y., JIA, G., GAO, Y., LI, B., & SUN, J. (2007) · Toxicology Letters · doi:10.1016/j.toxlet.2006.12.001 · Cited by 1,145
Biocompatibility of Advanced Manufactured Titanium Implants—A Review
Sidambe, A. (2014) · Materials · doi:10.3390/ma7128168 · Cited by 741
Bermudez, E., Mangum, J. B., Wong, B. A., Asgharian, B., Hext, P. M., Warheit, D. B., & Everitt, J. I. (2004) · Toxicological Sciences · doi:10.1093/toxsci/kfh019 · Cited by 652
Titanium dioxide in our everyday life; is it safe?
Skocaj, M., Filipic, M., Petkovic, J., & Novak, S. (2011) · Radiology and Oncology · doi:10.2478/v10019-011-0037-0 · Cited by 549
Cyto- and genotoxicity of ultrafine TiO2 particles in cultured human lymphoblastoid cells
Wang, J. J., Sanderson, B. J. S., & Wang, H. (2007) · Mutation Research/Genetic Toxicology and Environmental Mutagenesis · doi:10.1016/j.mrgentox.2006.12.003 · Cited by 534
WARHEIT, D., HOKE, R., FINLAY, C., DONNER, E., REED, K., & SAYES, C. (2007) · Toxicology Letters · doi:10.1016/j.toxlet.2007.04.008 · Cited by 507
Haynes, D. R., Rogers, S. D., Hay, S., Pearcy, M. J., & Howie, D. W. (1993) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199306000-00004 · Cited by 425
Fabian, E., Landsiedel, R., Ma-Hock, L., Wiench, K., Wohlleben, W., & van Ravenzwaay, B. (2008) · Archives of Toxicology · doi:10.1007/s00204-007-0253-y · Cited by 397
Cited by
A comprehensive review on metallic implant biomaterials and their subtractive manufacturing
Davis, R., Singh, A., Jackson, M. J., Coelho, R. T., Prakash, D., Charalambous, C. P., Ahmed, W., da Silva, L. R. R., & Lawrence, A. A. (2022) · The International Journal of Advanced Manufacturing Technology · doi:10.1007/s00170-022-08770-8 · Cited by 380
Periyasamy, A. (2023) · Toxics · doi:10.3390/toxics11050406 · Cited by 80
Metadata
- Authors
- Kim, K. T., Eo, M. Y., Nguyen, T. T. H., & Kim, S. M.
- Venue
- International Journal of Implant Dentistry
- Published
- 2019-03-11
- Volume
- 5
- Issue
- 1
- Pages
- 10-10
- ISSN
- 2198-4034 (ISSN-L)
- OpenAlex
- W2942008644
- Cited by
- 404
- References
- 52
- FWCI
- 17.11
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: General review of titanium toxicity. https://app.cochat.ai/papers/10.1186/s40729-019-0162-x
- The paper
- Kim, K. T., Eo, M. Y., Nguyen, T. T. H., & Kim, S. M. (2019). General review of titanium toxicity. International Journal of Implant Dentistry. https://doi.org/10.1186/s40729-019-0162-x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.