CoChat

Assessment of body composition by dual‐energy X‐ray absorptiometry, bioimpedance analysis and anthropometrics in children: the Physical Activity and Nutrition in Children study

Tompuri, Tuomo T., Lakka, Timo A., Hakulinen, Mikko, Lindi, Virpi, Laaksonen, David E., Kilpeläinen, Tuomas O., Jääskeläinen, Jarmo, Lakka, Hanna‐Maaria, Laitinen, Tomi · 2015 · Clinical Physiology and Functional Imaging
Cited by 98

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

Summary: Objective and methods: We compared I n B ody 720 segmental multifrequency bioimpedance analysis (SMF‐BIA) with L unar P rodigy A dvance dual‐energy X‐ray absorptiometry (DXA) in assessment of body composition among 178 predominantly prepubertal children. Segmental agreement analysis of body compartments was carried out, and inter‐relationships of anthropometric and other measures of body composition were defined. Moreover, the relations of different reference criteria for excess body fat were evaluated. Results: The prevalence of excess body fat varies greatly according to the used criteria. Intraclass and P earson's correlations between SMF‐BIA and DXA were >0·92 in total body and >0·74 in regional measures. SMF‐BIA underestimated percentage body fat (%BF) and fat mass (FM), and overestimated lean mass (LM) and percentage LM with significant offset trend bias. Higher adiposity increased offsets, and overall agreement was poorer in girls. On average, %BF offsets (girls/boys) and limits of agreement (LA) were 3·9/1·6% [(−)1·4–9·2%/(−)3·4–6·7%]. Interestingly percentage offsets of fat content (%BF: 18·9/10·1%, FM: 18·8/11·1%) showed no significant bias trends indicating that the corresponding absolute methodological offset depends on the amount of fat content. The smallest percentage offset was found with LM: 4·3/0·1%, referring offset (LA) of 0·88/0·03 kg (±2·05/±1·71 kg). Correspondingly, segmental LM had poorer agreement than total body LM. All anthropometrics except for the waist‐to‐hip ratio showed strong correlations (r = 0·76–0·95) with abdominal and total body fat. Conclusion: Segmental multifrequency bioimpedance analysis is precise enough for total‐LM analysis and had also sufficient trueness for total body composition analysis to be used in epidemiological purposes. There is need to generate scientifically and clinically relevant criteria and reference values for excess body fat.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/cpf.12118

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 98

Metadata

Authors
Tompuri, T. T., Lakka, T. A., Hakulinen, M., Lindi, V., Laaksonen, D. E., Kilpeläinen, T. O., Jääskeläinen, J., Lakka, H., & Laitinen, T.
Venue
Clinical Physiology and Functional Imaging
Publisher
Wiley
Published
2013-12-10
Volume
35
Issue
1
Pages
21-33
ISSN
  • 1475-0961 (ISSN-L)
  • 1475-097X
OpenAlex
W2089840598
Cited by
98
References
5
FWCI
3.88
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Assessment of body composition by dual‐energy X‐ray absorptiometry, bioimpedance analysis and anthropometrics in children: the Physical Activity and Nutrition in Children study. https://app.cochat.ai/papers/10.1111/cpf.12118
The paper
Tompuri, T. T., Lakka, T. A., Hakulinen, M., Lindi, V., Laaksonen, D. E., Kilpeläinen, T. O., Jääskeläinen, J., Lakka, H., & Laitinen, T. (2015). Assessment of body composition by dual‐energy X‐ray absorptiometry, bioimpedance analysis and anthropometrics in children: the Physical Activity and Nutrition in Children study. Clinical Physiology and Functional Imaging. https://doi.org/10.1111/cpf.12118

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.