CoChat

Responses to static stretching are dependent on stretch intensity and duration

Freitas, Sandro R., Vilarinho, Daniel, Vaz, João Rocha, Bruno, Paula M., Costa, Pablo B., Mil‐homens, Pedro · 2015 · Clinical Physiology and Functional Imaging
Cited by 63

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Summary: Information regarding the effects of stretching intensity on the joint torque–angle response is scarce. The present study examined the effects of three static stretching protocols with different intensities and durations on the passive knee extension torque–angle response of seventeen male participants (age ± SD: 23·9 ± 3·6 years, height: 177·0 ± 7·2 cm, BMI: 22·47 ± 1·95 kg·m 2). The stretching intensity was determined according to the maximal tolerable torque of the first repetition: fifty per cent (P50), seventy‐five per cent (P75) and the maximum intensity without pain (P100). Five repetitions were performed for each protocol. The stretch duration of each repetition was 90, 135 and 180 s for P100, P75 and P50, respectively. The rest period between repetitions was 30 s. Passive torque at a given angle, angle, stress relaxation, area under the curve, surface electromyography activity and visual analogue scale score were compared. The significant (P<0·05) results found were as follows: (i) the P50 and P75 did not increase the angle and passive peak torque outcomes, despite more time under stretch; (ii) only the P100 increased the angle and passive peak torque outcomes; (iii) the perception of stretching intensity mainly changed depending on knee angle changes, and not passive torque; (iv) the P50 induced a higher passive torque decrease; (v) when protocols were compared for the same time under stretch, the torque decrease was similar; (vi) the change in torque–angle curve shape was different depending on the stretching protocol. In conclusion, higher stretch duration seems to be a crucial factor for passive torque decrease and higher stretch intensity for maximum angle increase.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/cpf.12186

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

Metadata

Authors
Freitas, S. R., Vilarinho, D., Vaz, J. R., Bruno, P. M., Costa, P. B., & Mil‐homens, P.
Venue
Clinical Physiology and Functional Imaging
Publisher
Wiley
Published
2014-08-27
Volume
35
Issue
6
Pages
478-484
ISSN
  • 1475-0961 (ISSN-L)
  • 1475-097X
OpenAlex
W2096146814
Cited by
63
References
2
FWCI
3.45
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.