Responses to static stretching are dependent on stretch intensity and duration
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Summary: Information regarding the effects of stretching intensity on the joint torque–angle response is scarce. The present study examined the effects of three static stretching protocols with different intensities and durations on the passive knee extension torque–angle response of seventeen male participants (age ± SD: 23·9 ± 3·6 years, height: 177·0 ± 7·2 cm, BMI: 22·47 ± 1·95 kg·m 2). The stretching intensity was determined according to the maximal tolerable torque of the first repetition: fifty per cent (P50), seventy‐five per cent (P75) and the maximum intensity without pain (P100). Five repetitions were performed for each protocol. The stretch duration of each repetition was 90, 135 and 180 s for P100, P75 and P50, respectively. The rest period between repetitions was 30 s. Passive torque at a given angle, angle, stress relaxation, area under the curve, surface electromyography activity and visual analogue scale score were compared. The significant (P<0·05) results found were as follows: (i) the P50 and P75 did not increase the angle and passive peak torque outcomes, despite more time under stretch; (ii) only the P100 increased the angle and passive peak torque outcomes; (iii) the perception of stretching intensity mainly changed depending on knee angle changes, and not passive torque; (iv) the P50 induced a higher passive torque decrease; (v) when protocols were compared for the same time under stretch, the torque decrease was similar; (vi) the change in torque–angle curve shape was different depending on the stretching protocol. In conclusion, higher stretch duration seems to be a crucial factor for passive torque decrease and higher stretch intensity for maximum angle increase.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Development of recommendations for SEMG sensors and sensor placement procedures
Hermens, H. J., Freriks, B., Disselhorst-Klug, C., & Rau, G. (2000) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(00)00027-4 · Cited by 7,213
A mechanism for altered flexibility in human skeletal muscle.
Magnusson, S. P., Simonsen, E. B., Aagaard, P., Sørensen, H., & Kjaer, M. (1996) · The Journal of Physiology · doi:10.1113/jphysiol.1996.sp021768 · Cited by 406 · cited 1×
“In addition, previous studies have used the joint passive T–A curve to infer about structural adaptations after mechanical stimulus (McHugh et al., 1992; Magnusson et al., 1996; Ryan et al., 2008; Nakamura et al., 2011), by comparing the torque in a certain common angle.”
Method
Cited by
Nakamura, M., Yoshida, R., Sato, S., Yahata, K., Murakami, Y., Kasahara, K., Fukaya, T., Takeuchi, K., Nunes, J. P., & Konrad, A. (2021) · Frontiers in Physiology · doi:10.3389/fphys.2021.796497 · Cited by 54
“In fact, it was recently demonstrated that high-intensity SS exercise can induce an immediate larger change in stretch tolerance (Freitas et al., 2015).”
BackgroundAcute Effects of Stretching on Flexibility and Performance: A Narrative Review
Lima, C. D., Ruas, C. V., Behm, D. G., & Brown, L. E. (2019) · Journal of Science in Sport and Exercise · doi:10.1007/s42978-019-0011-x · Cited by 36
Sex differences in stretch-induced hypertrophy, maximal strength and flexibility gains
Warneke, K., Zech, A., Wagner, C.-M., Konrad, A., Nakamura, M., Keiner, M., Schoenfeld, B. J., & Behm, D. G. (2023) · Frontiers in Physiology · doi:10.3389/fphys.2022.1078301 · Cited by 27
“However, since intensity in stretching is often quantified using the VAS (Freitas et al., 2015; Warneke et al., 2022b; Warneke et al., 2022c; Hatano et al., 2022) there is a lack of objective quantification of stretching intensity in the present and previous studies (Lim and Park, 2017), consequently, the role of stre…”
Background
Metadata
- Authors
- Freitas, S. R., Vilarinho, D., Vaz, J. R., Bruno, P. M., Costa, P. B., & Mil‐homens, P.
- Venue
- Clinical Physiology and Functional Imaging
- Publisher
- Wiley
- Published
- 2014-08-27
- Volume
- 35
- Issue
- 6
- Pages
- 478-484
- ISSN
- 1475-0961 (ISSN-L)
- 1475-097X
- OpenAlex
- W2096146814
- Cited by
- 63
- References
- 2
- FWCI
- 3.45
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.