CoChat

Microphysiological Systems (“Organs‐on‐Chips”) for Drug Efficacy and Toxicity Testing

Open access
Low, LA, Tagle, DA · 2017 · Clinical and Translational Science
Cited by 53

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

The aim of the Microphysiological Systems (MPS) for Drug Efficacy and Toxicity Testing program, funded by the National Institutes of Health (NIH), was to address difficulties in drug and therapeutic development by creation of human organ microsystems. This program, now entering its fifth year, has achieved all milestones, and is expected to transform the predictive assessment of safety and effectiveness of promising therapeutics by pharmaceutical and regulatory agencies. Drug development is costly and time-consuming, and often has a high attrition rate. Toxicity and a lack of efficacy account for a large number of drug failures during the preclinical and clinical stages of testing of promising targets, in part due to differences between preclinical in vivo models (i.e., rodents) and humans in drug metabolizing enzymes and other physiological systems. To address this pressing issue, in 2010 the NIH and the US Food and Drug Administration (FDA) cofunded the Advancing Regulatory Sciences initiative to spur translational work in the regulatory sciences, funding a team at Harvard Wyss to develop a "Heart-lung micromachine" that contributed towards the highly publicized "lung-on-a-chip."1 Following from this success, in 2012 the NIH, alongside a parallel program from DARPA, tasked researchers with recreating 3D microfluidic organ systems ("tissue chips") using human cells that represented the characteristics and function of at least 10 major organ systems, and which were to remain viable in culture conditions for at least a month. The aim of these programs was to develop technologies that would be transformative for fast and effective evaluation of safety and efficacy in candidate therapeutics. The NIH funded 19 research projects through two funding opportunities, supporting research to explore the potential of stem and progenitor cells to differentiate into multiple cell types representing the gut, skin, bone, and brain, among others (RFA-RM-12-001), and to develop organ systems including the cardiopulmonary, female reproductive tract, liver sinusoid, kidney, and blood–brain barrier (RFA-RM-11-022). The 5-year programs to develop microphysiological systems (MPS) are now in their final year. The DARPA program funded two teams, and focused heavily on integration of multiple platforms into a "human-on-a-chip," which will end in mid-2017. The NIH program included an initial 2-year phase focusing on development of sustainable cell sources (i.e., human induced pluripotent stem cells, hiPSCs), while the second 3-year phase is now focusing on validation and functional integration of organ systems, and like the DARPA program will end in mid-2017. The FDA has provided regulatory guidance for both programs since inception. The MPS Consortium consists of NIH awardees and DARPA performers, plus government staff, and meets biannually in person to update Consortium members on recent progress, to share resources and expertise, and to collaborate in order to address challenges precompetitively. The Consortium meetings recently began including workshops with industry partners from the pharmaceutical and biotechnology fields, in order to gain critical feedback on how to move towards reproducibility, validation, and commercialization of MPS technology—a crucial step in making the technology more widely available for the research and pharmaceutical industries. One of the main aims of the NIH program was to develop systems that could then be accessible to the wider research community, either as tools for the drug development community, or for basic researchers working on understanding organ physiology. The application of MPS within the pharmaceutical industry could help streamline the drug development pipeline by providing "human relevant" assays for screening of promising drugs, but also would provide new avenues for screening of drugs to avoid failures in preclinical or early clinical trials phases. Additionally, with the capability of these platforms to be populated with patient-derived primary or iPSC sources, "orphan drugs"—those developed for rare diseases that have not yet been marketed— could be screened and tested in ways never before possible in living rare disease populations, potentially opening avenues of new treatments for a range of rare disorders.2 For basic researchers, the potential uses of tissue chips are also wide ranging. The utility of these chips to model 3D organ biology could allow new ways to study stem cell differentiation and maturation in in vivo-like systems, and help advance the science underlying the exciting potential of stem cell therapies and regenerative medicine. Additionally, chips representing different populations (age, gender, race) could lead to modeling of specific demographic variants, for a better understanding of genotypic and phenotypic variation within and between populations. Finally, the most useful application would likely be for disease modeling, enabling researchers to study and u

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/cts.12444

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 53

Metadata

Authors
Low, L., & Tagle, D.
Venue
Clinical and Translational Science
Publisher
Wiley
Published
2017-03-07
Volume
10
Issue
4
Pages
237-239
ISSN
  • 1752-8054 (ISSN-L)
  • 1752-8062
OpenAlex
W2578669683
Cited by
53
References
4
FWCI
4.54
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.