Can computerized clinical decision support systems improve diabetes management? A systematic review and meta‐analysis
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Aims: To systematically review randomized trials that assessed the effects of computerized clinical decision support systems in ambulatory diabetes management compared with a non‐computerized clinical decision support system control. Methods: We included all diabetes trials from a comprehensive computerized clinical decision support system overview completed in January 2010, and searched EMBASE, MEDLINE, INSPEC/COMPENDEX and Evidence‐Based Medicine Reviews (EBMR) from January 2010 to April 2012. Reference lists of related reviews, included articles and Clinicaltrials.gov were also searched. Randomized controlled trials of patients with diabetes in ambulatory care settings comparing a computerized clinical decision support system intervention with a non‐computerized clinical decision support system control, measuring either a process of care or a patient outcome, were included. Screening of studies, data extraction, risk of bias and quality of evidence assessments were carried out independently by two reviewers, and discrepancies were resolved through consensus or third‐party arbitration. Authors were contacted for any missing data. Results: Fifteen trials were included (13 from the previous review and two from the current search). Only one study was at low risk of bias, while the others were of moderate to high risk of bias because of methodological limitations. HbA 1c (3 months' follow‐up), quality of life and hospitalization (12 months' follow‐up) were pooled and all favoured the computerized clinical decision support systems over the control, although none were statistically significant. Triglycerides and practitioner performance tended to favour computerized clinical decision support systems although results were too heterogeneous to pool. Conclusions: Computerized clinical decision support systems in diabetes management may marginally improve clinical outcomes, but confidence in the evidence is low because of risk of bias, inconsistency and imprecision.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Individual determinants of research utilization by nurses: a systematic review update
Squires, J. E., Estabrooks, C. A., Gustavsson, P., & Wallin, L. (2011) · Implementation Science · doi:10.1186/1748-5908-6-1 · Cited by 798
Quinn, C. C., Shardell, M. D., Terrin, M. L., Barr, E. A., Ballew, S. H., & Gruber-Baldini, A. L. (2011) · Diabetes Care · doi:10.2337/dc11-0366 · Cited by 650 · cited 5×
“Two studies [7,12] reported the number of participants hospitalized and three studies [7,10,13] reported effects on quality of life.”
BackgroundMethodInfluentialQuinn, C. C., Clough, S. S., Minor, J. M., Lender, D., Okafor, M. C., & Gruber-Baldini, A. (2008) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2008.0283 · Cited by 406
Informatics systems to promote improved care for chronic illness: a literature review
Dorr, D., Bonner, L. M., Cohen, A. N., Shoai, R. S., Perrin, R., Chaney, E., & Young, A. S. (2007) · Journal of the American Medical Informatics Association · doi:10.1197/jamia.m2255 · Cited by 257 · cited 1×
“This is particularly important in chronic disease management, as treatments that are known to be beneficial are only prescribed approximately half of the time, while ineffective treatments, such as the wrong dose or drug, can be provided up to 30% of the time [3,4].”
BackgroundChristian, J. G. (2008) · Archives of Internal Medicine · doi:10.1001/archinternmed.2007.13 · Cited by 166 · cited 2×
“We were unable to pool HbA 1c at 6 months [10,16] or 12 months [7,10,11,13,17,18] nor practitioner performance outcomes at 3 months [15,19,20], 6 or 12 months because of high heterogeneity ( I 2 > 0.6).”
BackgroundInfluentialBennett, J. W., & Glasziou, P. P. (2003) · Medical Journal of Australia · doi:10.5694/j.1326-5377.2003.tb05166.x · Cited by 146 · cited 1×
“This is particularly important in chronic disease management, as treatments that are known to be beneficial are only prescribed approximately half of the time, while ineffective treatments, such as the wrong dose or drug, can be provided up to 30% of the time [3,4].”
Cited by
Aarons, G. A., Ehrhart, M. G., Farahnak, L. R., & Sklar, M. (2014) · Annual Review of Public Health · doi:10.1146/annurev-publhealth-032013-182447 · Cited by 474
Moja, L., Kwag, K. H., Lytras, T., Bertizzolo, L., Brandt, L., Pecoraro, V., Rigon, G., Vaona, A., Ruggiero, F., Mangia, M., et al. (2014) · American Journal of Public Health · doi:10.2105/ajph.2014.302164 · Cited by 339
Kumar, R. B., Goren, N. D., Stark, D. E., Wall, D. P., & Longhurst, C. A. (2016) · Journal of the American Medical Informatics Association · doi:10.1093/jamia/ocv206 · Cited by 126
Miller, A., Moon, B., Anders, S., Walden, R., Brown, S., & Montella, D. (2015) · International Journal of Medical Informatics · doi:10.1016/j.ijmedinf.2015.09.005 · Cited by 106
Murphy, M. E., Byrne, M., Galvin, R., Boland, F., Fahey, T., & Smith, S. M. (2017) · BMJ Open · doi:10.1136/bmjopen-2016-015135 · Cited by 94
Metadata
- Authors
- Jeffery, R., Iserman, E., Haynes, R. B., & the CDSS Systematic Review Team
- Venue
- Diabetic Medicine
- Publisher
- Wiley
- Published
- 2013-02-28
- Volume
- 30
- Issue
- 6
- Pages
- 739-745
- ISSN
- 0742-3071 (ISSN-L)
- 1464-5491
- OpenAlex
- W2034278128
- Cited by
- 89
- References
- 6
- FWCI
- 0.87
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.