CoChat

Evaluation of subcutaneous glucose monitoring systems under routine environmental conditions in patients with type 1 diabetes

Open access
Aberer, Felix, Hajnsek, Martin, Rumpler, Markus, Zenz, Sabine, Baumann, Petra M., Elsayed, Hesham, Puffing, Adelheid, Treiber, Gerlies, Pieber, Thomas R., Sourij, Harald, Mader, Julia K. · 2017 · Diabetes, Obesity and Metabolism
Cited by 132

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Continuous and flash glucose monitoring ( GM ) systems have been established in diabetes care. We compared the sensor performance of 3 commercially available GM systems. A total of 12 patients with type 1 diabetes were included in a single‐centre, open‐label study in which the sensor performance of the A bbott FreeStyle libre ( A bbott), D excom G4 P latinum ( D excom) and M edtronic MiniMed 640G ( M edtronic) systems over 12 hours was compared during mimicked real‐life conditions (meals, exercise, hypo‐ and hyperglycaemia). Sensor performance was determined by fulfilment of ISO 15197:2013 criteria, calculating mean absolute relative difference ( MARD ), and was also illustrated using P arkes error grid and B land– A ltman plots. Sensor performance during changes in metabolic variables (lactate, betahydroxybutyrate, glucagon, non‐esterified‐fatty‐acids) was determined by S pearman's rank correlation coefficient testing. The systems fulfilled ISO 15197:2013 criteria by 73.2% ( A bbott), 56.1% ( D excom) and 52.0% ( M edtronic). The MARDs ± standard deviation in the entire glycaemic range were 13.2% ± 10.9% ( A bbott), 16.8% ± 12.3% ( D excom) and 21.4% ± 17.6% ( M edtronic), respectively. All sensors performed less accurately during hypoglycaemia and best during hyperglycaemia. We did not observe an influence of metabolic variables on sensor performance.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/dom.12907

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 132

Metadata

Authors
Aberer, F., Hajnsek, M., Rumpler, M., Zenz, S., Baumann, P. M., Elsayed, H., Puffing, A., Treiber, G., Pieber, T. R., Sourij, H., & Mader, J. K.
Venue
Diabetes, Obesity and Metabolism
Publisher
Wiley
Published
2017-03-16
Volume
19
Issue
7
Pages
1051-1055
ISSN
  • 1462-8902 (ISSN-L)
  • 1463-1326
OpenAlex
W2588920211
Cited by
132
References
2
FWCI
13.36
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Evaluation of subcutaneous glucose monitoring systems under routine environmental conditions in patients with type 1 diabetes. https://app.cochat.ai/papers/10.1111/dom.12907
The paper
Aberer, F., Hajnsek, M., Rumpler, M., Zenz, S., Baumann, P. M., Elsayed, H., Puffing, A., Treiber, G., Pieber, T. R., Sourij, H., & Mader, J. K. (2017). Evaluation of subcutaneous glucose monitoring systems under routine environmental conditions in patients with type 1 diabetes. Diabetes, Obesity and Metabolism. https://doi.org/10.1111/dom.12907

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.