Evaluation of subcutaneous glucose monitoring systems under routine environmental conditions in patients with type 1 diabetes
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Continuous and flash glucose monitoring ( GM ) systems have been established in diabetes care. We compared the sensor performance of 3 commercially available GM systems. A total of 12 patients with type 1 diabetes were included in a single‐centre, open‐label study in which the sensor performance of the A bbott FreeStyle libre ( A bbott), D excom G4 P latinum ( D excom) and M edtronic MiniMed 640G ( M edtronic) systems over 12 hours was compared during mimicked real‐life conditions (meals, exercise, hypo‐ and hyperglycaemia). Sensor performance was determined by fulfilment of ISO 15197:2013 criteria, calculating mean absolute relative difference ( MARD ), and was also illustrated using P arkes error grid and B land– A ltman plots. Sensor performance during changes in metabolic variables (lactate, betahydroxybutyrate, glucagon, non‐esterified‐fatty‐acids) was determined by S pearman's rank correlation coefficient testing. The systems fulfilled ISO 15197:2013 criteria by 73.2% ( A bbott), 56.1% ( D excom) and 52.0% ( M edtronic). The MARDs ± standard deviation in the entire glycaemic range were 13.2% ± 10.9% ( A bbott), 16.8% ± 12.3% ( D excom) and 21.4% ± 17.6% ( M edtronic), respectively. All sensors performed less accurately during hypoglycaemia and best during hyperglycaemia. We did not observe an influence of metabolic variables on sensor performance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Performance and Usability of a Factory-Calibrated Flash Glucose Monitoring System
Bailey, T., Bode, B. W., Christiansen, M. P., Klaff, L. J., & Alva, S. (2015) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2014.0378 · Cited by 685 · cited 1×
“Previous studies showed that sensor performance was not weakened during the remaining period of designated time of use.(1,16) Another limitation of the study is that sensor performance”
BackgroundClinical accuracy of a continuous glucose monitoring system with an advanced algorithm
Bailey, T. S., Chang, A., & Christiansen, M. (2015) · Journal of Diabetes Science and Technology · doi:10.1177/1932296814559746 · Cited by 168 · cited 1×
“In the meantime newer versions of 2 of the 3 tested systems have been presented (Enlite 3, Medtronic; Dexcom G5, Dexcom), reporting MARDs of <10% according to the manufacturers, but, to date, no direct standardized comparison is available and only Dexcom G5 has so far been marketed.(17)”
Cited by
Galindo, R. J., Migdal, A. L., Davis, G. M., Urrutia, M. A., Albury, B., Zambrano, C., Vellanki, P., Pasquel, F. J., Fayfman, M., Peng, L., et al. (2020) · Diabetes Care · doi:10.2337/dc19-2073 · Cited by 181
“FreeStyle Libre and other CGMsystems havebeen reported tohave lower accuracy in the hypoglycemic range (26,27,30).”
Background7. Diabetes Technology: Standards of Medical Care in Diabetes—2019
American Diabetes Association (2019) · Diabetes Care · doi:10.2337/dc19-s007 · Cited by 179
Positioning time in range in diabetes management
Advani, A. (2020) · Diabetologia · doi:10.1007/s00125-019-05027-0 · Cited by 170
Heinemann, L., Schoemaker, M., Schmelzeisen-Redecker, G., Hinzmann, R., Kassab, A., Freckmann, G., Reiterer, F., & Del Re, L. (2020) · Journal of Diabetes Science and Technology · doi:10.1177/1932296819855670 · Cited by 170
Freckmann, G., Eichenlaub, M., Waldenmaier, D., Pleus, S., Wehrstedt, S., Haug, C., Witthauer, L., Jendle, J., Hinzmann, R., Thomas, A., et al. (2023) · Journal of Diabetes Science and Technology · doi:10.1177/19322968231190941 · Cited by 86
Metadata
- Authors
- Aberer, F., Hajnsek, M., Rumpler, M., Zenz, S., Baumann, P. M., Elsayed, H., Puffing, A., Treiber, G., Pieber, T. R., Sourij, H., & Mader, J. K.
- Venue
- Diabetes, Obesity and Metabolism
- Publisher
- Wiley
- Published
- 2017-03-16
- Volume
- 19
- Issue
- 7
- Pages
- 1051-1055
- ISSN
- 1462-8902 (ISSN-L)
- 1463-1326
- OpenAlex
- W2588920211
- Cited by
- 132
- References
- 2
- FWCI
- 13.36
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Evaluation of subcutaneous glucose monitoring systems under routine environmental conditions in patients with type 1 diabetes. https://app.cochat.ai/papers/10.1111/dom.12907
- The paper
- Aberer, F., Hajnsek, M., Rumpler, M., Zenz, S., Baumann, P. M., Elsayed, H., Puffing, A., Treiber, G., Pieber, T. R., Sourij, H., & Mader, J. K. (2017). Evaluation of subcutaneous glucose monitoring systems under routine environmental conditions in patients with type 1 diabetes. Diabetes, Obesity and Metabolism. https://doi.org/10.1111/dom.12907
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.