Increased proportion of time in hybrid closed‐loop “Auto Mode” is associated with improved glycaemic control for adolescent and young patients with adult type 1 diabetes using the MiniMed 670G insulin pump
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
The Medtronic MiniMed 670G system delivers insulin to patients with type 1 diabetes mellitus (T1DM) using either its hybrid closed‐loop (HCL) “Auto Mode” feature or an open‐loop mode. In this retrospective, cross‐sectional analysis, we quantified the association between time in Auto Mode and both haemoglobin A1c (HbA1c) and time in range (TIR, sensor glucose 70–180 mg/dL) among 96 paediatric and young adult patients with T1DM. The median percentage time in Auto Mode was 38.5% (interquartile range 0%–64%). The percentage time in Auto Mode significantly correlated with HbA1c after adjustment for covariables (β = −0.008, P = 0.014). Each daily 3.4‐h increase in Auto Mode time was associated with a 0.1% decrease in HbA1c. Auto Mode time was also correlated with TIR after adjustment for covariables (β = 0.14, P = 0.02): for each daily 8.6‐h increase in Auto Mode time, TIR increased by 5%. While Auto Mode use was low, increased time in Auto Mode was associated with a significantly lower HbA1c and increased TIR. These findings emphasize the importance of identifying strategies to improve the ease of use of HCL systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Miller, K. M., Foster, N. C., Beck, R. W., Bergenstal, R. M., DuBose, S. N., DiMeglio, L. A., Maahs, D. M., & Tamborlane, W. V. (2015) · Diabetes Care · doi:10.2337/dc15-0078 · Cited by 1,254 · cited 1×
“0%.(5) In our cohort, the median HbA1c was 7.”
BackgroundGarg, S. K., Weinzimer, S. A., Tamborlane, W. V., Buckingham, B. A., Bode, B. W., Bailey, T. S., Brazg, R. L., Ilany, J., Slover, R. H., Anderson, S. M., et al. (2017) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2016.0421 · Cited by 585 · cited 9×
“In the cohort analysed, each 3.4-h increase in Auto Mode time per day was associated with a 0.1% lower HbA1c.”
BackgroundResultInfluentialPoolsup, N., Suksomboon, N., & Kyaw, A. M. (2013) · Diabetology & Metabolic Syndrome · doi:10.1186/1758-5996-5-39 · Cited by 179
Cited by
A Randomized Trial of Closed-Loop Control in Children with Type 1 Diabetes
Breton, M. D., Kanapka, L. G., Beck, R. W., Ekhlaspour, L., Forlenza, G. P., Cengiz, E., Schoelwer, M., Ruedy, K. J., Jost, E., Carria, L., et al. (2020) · New England Journal of Medicine · doi:10.1056/nejmoa2004736 · Cited by 455
Bergenstal, R. M., Nimri, R., Beck, R. W., Criego, A., Laffel, L., Schatz, D., Battelino, T., Danne, T., Weinzimer, S. A., Sibayan, J., et al. (2021) · The Lancet · doi:10.1016/s0140-6736(20)32514-9 · Cited by 344
New closed-loop insulin systems
Boughton, C. K., & Hovorka, R. (2021) · Diabetologia · doi:10.1007/s00125-021-05391-w · Cited by 270
Carlson, A. L., Sherr, J. L., Shulman, D. I., Garg, S. K., Pop-Busui, R., Bode, B. W., Lilenquist, D. R., Brazg, R. L., Kaiserman, K. B., Kipnes, M. S., et al. (2022) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2021.0319 · Cited by 230
Real-World Patient-Reported Outcomes and Glycemic Results with Initiation of Control-IQ Technology
Pinsker, J. E., Müller, L., Constantin, A., Leas, S., Manning, M., McElwee Malloy, M., Singh, H., & Habif, S. (2021) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2020.0388 · Cited by 147
“21 A considerable amount of literature has been developed on how to help patients with diabetes use AID systems, particularly related to keeping closed-loop automation active.”
A Systematic Review of Commercial Hybrid Closed-Loop Automated Insulin Delivery Systems
Peacock, S., Frizelle, I., & Hussain, S. (2023) · Diabetes Therapy · doi:10.1007/s13300-023-01394-5 · Cited by 122
Isganaitis, E., Raghinaru, D., Ambler-Osborn, L., Pinsker, J. E., Buckingham, B. A., Wadwa, R. P., Ekhlaspour, L., Kudva, Y. C., Levy, C. J., Forlenza, G. P., et al. (2021) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2020.0572 · Cited by 115
Real-world evidence of automated insulin delivery system use
Considine, E. G., & Sherr, J. L. (2024) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2023.0442 · Cited by 59
“60 However, time in automation was relatively low with median use of 38.5% (range 0%–64%), highlighting the need to identify strategies to remain in automation and/or development of systems that would have fewer reversions to manual mode.”
Influential
Metadata
- Authors
- Duffus, S. H., Ta'ani, Z. A., Slaughter, J. C., Niswender, K. D., & Gregory, J. M.
- Venue
- Diabetes, Obesity and Metabolism
- Publisher
- Wiley
- Published
- 2019-12-09
- Volume
- 22
- Issue
- 4
- Pages
- 688-693
- ISSN
- 1462-8902 (ISSN-L)
- 1463-1326
- OpenAlex
- W2986909781
- Cited by
- 55
- References
- 3
- FWCI
- 6.02
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.