CoChat

Reducing the need for carbohydrate counting in type 1 diabetes using closed‐loop automated insulin delivery (artificial pancreas) and empagliflozin: A randomized, controlled, non‐inferiority, crossover pilot trial

Haidar, Ahmad, Yale, Jean‐Francois, Lovblom, Leif Erik, Cardinez, Nancy, Orszag, Andrej, Falappa, C. Marcelo, Gouchie‐Provencher, Nikita, Tsoukas, Michael A., El Fathi, Anas, Rene, Jennifer, Eldelekli, Devrim, Lanctôt, Sebastien O., Scarr, Daniel, Perkins, Bruce A. · 2021 · Diabetes, Obesity and Metabolism
Cited by 42

The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.

Abstract

Aim: To assess whether adding empagliflozin to closed‐loop automated insulin delivery could reduce the need for carbohydrate counting in type 1 diabetes (T1D) without worsening glucose control. Materials and Methods: In an open‐label, crossover, non‐inferiority trial, 30 adult participants with T1D underwent outpatient automated insulin delivery interventions with three random sequences of prandial insulin strategy days: carbohydrate counting, simple meal announcement (no carbohydrate counting) and no meal announcement. During each sequence of prandial insulin strategies, participants were randomly assigned empagliflozin (25 mg/day) or not, and crossed over to the comparator. Mean glucose for carbohydrate counting without empagliflozin (control) was compared with no meal announcement with empagliflozin (in the primary non‐inferiority comparison) and simple meal announcement with empagliflozin (in the conditional primary non‐inferiority comparison). Results: Participants were aged 40 ± 15 years, had 27 ± 15 years diabetes duration and HbA1c of 7.6% ± 0.7% (59 ± 8 mmol/mol). The system with no meal announcement and empagliflozin was not non‐inferior (and thus reasonably considered inferior) to the control arm (mean glucose 10.0 ± 1.6 vs. 8.5 ± 1.5 mmol/L; non‐inferiority p = .94), while simple meal announcement and empagliflozin was non‐inferior (8.5 ± 1.4 mmol/L; non‐inferiority p = .003). Use of empagliflozin on the background of automated insulin delivery with carbohydrate counting was associated with lower mean glucose, corresponding to a 14% greater time in the target range. While no ketoacidosis was observed, mean fasting ketones levels were higher on empagliflozin (0.22 ± 0.18 vs. 0.13 ± 0.11 mmol/L; p < .001). Conclusions: Empagliflozin added to automated insulin delivery has the potential to eliminate the need for carbohydrate counting and improves glycaemic control in conjunction with carbohydrate counting, but does not allow for the elimination of meal announcement.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/dom.14335

Cites

13 of 13 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 42

Metadata

Authors
Haidar, A., Yale, J., Lovblom, L. E., Cardinez, N., Orszag, A., Falappa, C. M., Gouchie‐Provencher, N., Tsoukas, M. A., El Fathi, A., Rene, J., Eldelekli, D., Lanctôt, S. O., Scarr, D., & Perkins, B. A.
Venue
Diabetes, Obesity and Metabolism
Publisher
Wiley
Published
2021-02-28
Volume
23
Issue
6
Pages
1272-1281
ISSN
  • 1462-8902 (ISSN-L)
  • 1463-1326
OpenAlex
W3126647711
Cited by
42
References
13
FWCI
4.36
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.