Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 234

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Correlation of Left Atrial Strain and Doppler Measurements with Invasive Measurement of Left Ventricular End‐Diastolic Pressure in Patients Stratified for Different Values of Ejection Fraction

Open access
Cameli, Matteo, Sparla, Stefania, Losito, Maurizio, Righini, Francesca M., Menci, Daniele, Lisi, Matteo, D'Ascenzi, Flavio, Focardi, Marta, Favilli, Roberto, Pierli, Carlo, Fineschi, Massimo, Mondillo, Sergio·2016·Echocardiography

Abstract

Background: This study aimed at exploring the correlation of left atrial longitudinal function by speckle tracking echocardiography (left atrial strain) and Doppler measurements (E/E' ratio) with direct measurements of left ventricular (LV) end‐diastolic pressure (LVEDP) in patients stratified for different values of ejection fraction. Methods: The study population was 80 stable patients with sinus rhythm undergoing cardiac catheterization. This population was selected in order to have four groups of 20 patients each with different LV ejection fraction (>55%, 45–54%, 30–44%, and <30%). LVEDP was obtained during cardiac catheterization; peak atrial longitudinal strain (PALS) and mean E/E' ratio were measured in all subjects. Results: Similar correlations with LVEDP of global PALS and E/E' ratio were recorded in patients with preserved (r = −0.79 vs. r = 0.72, respectively; P < 0.0001 for both) or mildly reduced ejection fraction (r = −0.75 vs. r = 0.73, respectively; P < 0.0001 for both). A closer correlation of global PALS compared to E/E' ratio was evident in patients with moderate (r = −0.78 P < 0.0001; vs. r = 0.47 P = 0.01, respectively) and severe reduction (r = −0.74 P < 0.0001; vs. r = 0.19 ns, respectively) of LV ejection fraction. In multivariate analysis of all measurements, global PALS emerged as a determinant of the LVEDP, independent on other confounding factors and, with the cutoff value of 18.0% presented the best diagnostic accuracy to predict a LVDP above 12 mmHg (AUC 0.87). Conclusions: In patients with preserved or mildly reduced LV ejection fraction, global PALS and mean E/E' ratio presented good correlations with LVEDP. In patients with moderate or severe reduction of ejection fraction, E/E' ratio correlated poorly with invasively obtained LV filling pressures. Global PALS provided an overall better estimation of LV filling pressures.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/echo.13094

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

Metadata

Authors
Cameli, M., Sparla, S., Losito, M., Righini, F. M., Menci, D., Lisi, M., D'Ascenzi, F., Focardi, M., Favilli, R., Pierli, C., Fineschi, M., & Mondillo, S.
Venue
Echocardiography
Publisher
Wiley
Published
2015-10-23
Volume
33
Issue
3
Pages
398-405
ISSN
  • 0742-2822 (ISSN-L)
  • 1540-8175
OpenAlex
W2158579769
Cited by
234
References
2
FWCI
4.91
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.