CoChat

Switching from constant voltage to constant current in deep brain stimulation: a multicenter experience of mixed implants for movement disorders

Open access
Preda, F., Cavandoli, C., Lettieri, C., Pilleri, M., Antonini, A., Eleopra, R., Mondani, M., Martinuzzi, A., Sarubbo, S., Ghisellini, G., Trezza, A., Cavallo, M. A., Landi, A., Sensi, M. · 2016 · European Journal of Neurology
Cited by 43

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Background and purpose: For many years deep brain stimulation (DBS) devices relied only on voltage‐controlled stimulation (CV), but recently current‐controlled devices have been developed and approved for new implants as well as for replacement of CV devices after battery drain. Constant‐current (CC) stimulation has been demonstrated to be effective in new implanted parkinsonian and dystonic patients, but the effect of switching to CC therapy in patients chronically stimulated with CV implantable pulse generators (IPG s) has not been assessed. This report shows the results of a consecutive retrospective data collection performed at five Italian centers before and after replacement of constant‐voltage with constant‐current DBS devices, in order to verify the clinical efficacy and safety of this procedure. Methods: Nineteen patients with Parkinson's disease or dystonic syndrome underwent DBS IPG CV/CC replacement. Clinical features and therapy satisfaction were assessed before surgery, 1 week after and 3 and 6 months after replacement. Programming settings and impedances were recorded before removing the CV device and when the CC IPG s were switched on. Results: The clinical outcome of CC stimulation was similar to that obtained with CV devices and remained stable at 3 and 6 months of follow‐up. Impedance values recorded for CV and CC IPG s were similar. Ninety‐five percent of patients and physicians were satisfied with mixed implants. No adverse events occurred after IPG replacement. Conclusion: Replacing CV with CC IPG s is a safe and effective procedure. Longer follow‐up is necessary to better clarify the impact of CC stimulation on clinical outcome after chronic stimulation in CV mode.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/ene.12835

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

Metadata

Authors
Preda, F., Cavandoli, C., Lettieri, C., Pilleri, M., Antonini, A., Eleopra, R., Mondani, M., Martinuzzi, A., Sarubbo, S., Ghisellini, G., Trezza, A., Cavallo, M. A., Landi, A., & Sensi, M.
Venue
European Journal of Neurology
Publisher
Wiley
Published
2015-10-25
Volume
23
Issue
1
Pages
190-195
ISSN
  • 1351-5101 (ISSN-L)
  • 1468-1331
OpenAlex
W2148269042
Cited by
43
References
1
FWCI
3.64
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.