Detection of generalized tonic–clonic seizures using surface electromyographic monitoring
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
Summary: Objective: A prospective multicenter phase III trial was undertaken to evaluate the performance and tolerability in the epilepsy monitoring unit ( EMU ) of an investigational wearable surface electromyographic ( sEMG ) monitoring system for the detection of generalized tonic–clonic seizures ( GTCSs ). Methods: One hundred ninety‐nine patients with a history of GTCSs who were admitted to the EMU in 11 level IV epilepsy centers for clinically indicated video‐electroencephalographic monitoring also received sEMG monitoring with a wearable device that was worn on the arm over the biceps muscle. All recorded sEMG data were processed at a central site using a previously developed detection algorithm. Detected GTCSs were compared to events verified by a majority of three expert reviewers. Results: For all subjects, the detection algorithm detected 35 of 46 (76%, 95% confidence interval [CI] = 0.61–0.87) of the GTCSs, with a positive predictive value ( PPV ) of 0.03 and a mean false alarm rate ( FAR ) of 2.52 per 24 h. For data recorded while the device was placed over the midline of the biceps muscle, the system detected 29 of 29 GTCSs (100%, 95% CI = 0.88–1.00), with a detection delay averaging 7.70 s, a PPV of 6.2%, and a mean FAR of 1.44 per 24 h. Mild to moderate adverse events were reported in 28% (55 of 199) of subjects and led to study withdrawal in 9% (17 of 199). These adverse events consisted mostly of skin irritation caused by the electrode patch that resolved without treatment. No serious adverse events were reported. Significance: Detection of GTCSs using an sEMG monitoring device on the biceps is feasible. Proper positioning of this device is important for accuracy, and for some patients, minimizing the number of false positives may be challenging.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Berg, A. T., Berkovic, S. F., Brodie, M. J., Buchhalter, J., Cross, J. H., Van Emde Boas, W., Engel, J., French, J., Glauser, T. A., Mathern, G. W., et al. (2010) · Epilepsia · doi:10.1111/j.1528-1167.2010.02522.x · Cited by 4,363
Self-citationComputing inter‐rater reliability and its variance in the presence of high agreement
Gwet, K. L. (2008) · British Journal of Mathematical and Statistical Psychology · doi:10.1348/000711006x126600 · Cited by 2,167
STARD 2015: An Updated List of Essential Items for Reporting Diagnostic Accuracy Studies
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L., Lijmer, J. G., Moher, D., Rennie, D., de Vet, H. C. W., et al. (2015) · Clinical Chemistry · doi:10.1373/clinchem.2015.246280 · Cited by 984
Lhatoo, S. D., Johnson, A. L., Goodridge, D. M., MacDonald, B. K., Sander, J. W. A. S., & Shorvon, S. D. (2001) · Annals of Neurology · doi:10.1002/ana.70 · Cited by 342
Sudden unexpected death in epilepsy: people with nocturnal seizures may be at highest risk
Lamberts, R. J., Thijs, R. D., Laffan, A., Langan, Y., & Sander, J. W. (2012) · Epilepsia · doi:10.1111/j.1528-1167.2011.03360.x · Cited by 322
Beniczky, S., Polster, T., Kjaer, T. W., & Hjalgrim, H. (2013) · Epilepsia · doi:10.1111/epi.12120 · Cited by 230
Novel techniques for automated seizure registration: Patients' wants and needs
Hoppe, C., Feldmann, M., Blachut, B., Surges, R., Elger, C. E., & Helmstaedter, C. (2015) · Epilepsy & Behavior · doi:10.1016/j.yebeh.2015.08.006 · Cited by 116 · cited 1×
“Surveys of patients with epilepsy (and their caregivers) have shown that they would strongly consider applying and permanently using a device to detect seizures, especially if the device is wearable (removable) and worn either on the wrist or as a patch over an invisible body site.(19) As reported by Van de Vel et al.”
BackgroundTracking generalized tonic-clonic seizures with a wrist accelerometer linked to an online database
Velez, M., Fisher, R. S., Bartlett, V., & Le, S. (2016) · Seizure · doi:10.1016/j.seizure.2016.04.009 · Cited by 65 · cited 1×
“3%) in nine patients in the EMU with 81 FAs (with the FAR not detailed).(17) A previous study of the SmartWatch had shown only a 31% sensitivity for detecting GTCS (with the FAR not reported).”
Background
Cited by
Diagnostic challenges in epilepsy: seizure under-reporting and seizure detection
Elger, C. E., & Hoppe, C. (2018) · The Lancet Neurology · doi:10.1016/s1474-4422(18)30038-3 · Cited by 403
Karoly, P. J., Rao, V. R., Gregg, N. M., Worrell, G. A., Bernard, C., Cook, M. J., & Baud, M. O. (2021) · Nature Reviews Neurology · doi:10.1038/s41582-021-00464-1 · Cited by 262
The Role of Wearable Devices in Chronic Disease Monitoring and Patient Care: A Comprehensive Review
Jafleh, E. A., Alnaqbi, F. A., Almaeeni, H. A., Faqeeh, S., Alzaabi, M. A., & Al Zaman, K. (2024) · Cureus · doi:10.7759/cureus.68921 · Cited by 125
“Currently, the market lacks wearable devices that detect seizures other than TCS [64], and devices under study failed to detect all types of seizures [65,66].”
Non-invasive wearable seizure detection using long–short-term memory networks with transfer learning
Nasseri, M., Pal Attia, T., Joseph, B., Gregg, N. M., Nurse, E. S., Viana, P. F., Schulze-Bonhage, A., Dümpelmann, M., Worrell, G., Freestone, D. R., et al. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/abef8a · Cited by 66
Noninvasive Continuous Monitoring of Vital Signs With Wearables: Fit for Medical Use?
Jacobsen, M., Dembek, T. A., Kobbe, G., Gaidzik, P. W., & Heinemann, L. (2021) · Journal of Diabetes Science and Technology · doi:10.1177/1932296820904947 · Cited by 49
Böttcher, S., Bruno, E., Manyakov, N. V., Epitashvili, N., Claes, K., Glasstetter, M., Thorpe, S., Lees, S., Dümpelmann, M., Van Laerhoven, K., et al. (2021) · JMIR mHealth and uHealth · doi:10.2196/27674 · Cited by 39
“Finally, electromyography is a self-evident modality for detecting seizures with motor components, identifying ictal muscle contraction, and thus has been used for convulsive seizure detection as well [25-28].”
MethodHubbard, I., Beniczky, S., & Ryvlin, P. (2021) · Frontiers in Neurology · doi:10.3389/fneur.2021.740743 · Cited by 34
Patients self-mastery of wearable devices for seizure detection: A direct user-experience
Bruno, E., Biondi, A., Thorpe, S., & Richardson, M. P. (2020) · Seizure · doi:10.1016/j.seizure.2020.08.023 · Cited by 25
Glasstetter, M., Böttcher, S., Zabler, N., Epitashvili, N., Dümpelmann, M., Richardson, M. P., & Schulze-Bonhage, A. (2021) · Sensors · doi:10.3390/s21186017 · Cited by 21
Metadata
- Authors
- Halford, J. J., Sperling, M. R., Nair, D. R., Dlugos, D. J., Tatum, W. O., Harvey, J., French, J. A., Pollard, J. R., Faught, E., Noe, K. H., Henry, T. R., Jetter, G. M., Lie, O. V., Morgan, L. C., Girouard, M. R., Cardenas, D. P., Whitmire, L. E., & Cavazos, J. E.
- Venue
- Epilepsia
- Publisher
- Wiley
- Published
- 2017-10-05
- Volume
- 58
- Issue
- 11
- Pages
- 1861-1869
- ISSN
- 0013-9580 (ISSN-L)
- 1528-1167
- OpenAlex
- W2764203772
- Cited by
- 107
- References
- 8
- FWCI
- 9.37
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.