CoChat

Machine learning from wristband sensor data for wearable, noninvasive seizure forecasting

Open access
Meisel, Christian, El Atrache, Rima, Jackson, Michele, Schubach, Sarah, Ufongene, Claire, Loddenkemper, Tobias · 2020 · Epilepsia
Cited by 120

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

Objective: Seizure forecasting may provide patients with timely warnings to adapt their daily activities and help clinicians deliver more objective, personalized treatments. Although recent work has convincingly demonstrated that seizure risk assessment is in principle possible, these early approaches relied largely on complex, often invasive setups including intracranial electrocorticography, implanted devices, and multichannel electroencephalography, and required patient‐specific adaptation or learning to perform optimally, all of which limit translation to broad clinical application. To facilitate broader adaptation of seizure forecasting in clinical practice, noninvasive, easily applicable techniques that reliably assess seizure risk without much prior tuning are crucial. Wristbands that continuously record physiological parameters, including electrodermal activity, body temperature, blood volume pulse, and actigraphy, may afford monitoring of autonomous nervous system function and movement relevant for such a task, hence minimizing potential complications associated with invasive monitoring and avoiding stigma associated with bulky external monitoring devices on the head. Methods: Here, we applied deep learning on multimodal wristband sensor data from 69 patients with epilepsy (total duration > 2311 hours, 452 seizures) to assess its capability to forecast seizures in a statistically significant way. Results: Using a leave‐one‐subject‐out cross‐validation approach, we identified better‐than‐chance predictability in 43% of the patients. Time‐matched seizure surrogate data analyses indicated forecasting not to be driven simply by time of day or vigilance state. Prediction performance peaked when all sensor modalities were used, and did not differ between generalized and focal seizure types, but generally increased with the size of the training dataset, indicating potential further improvement with larger datasets in the future. Significance: Collectively, these results show that statistically significant seizure risk assessments are feasible from easy‐to‐use, noninvasive wearable devices without the need of patient‐specific training or parameter optimization.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/epi.16719

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 120

Metadata

Authors
Meisel, C., El Atrache, R., Jackson, M., Schubach, S., Ufongene, C., & Loddenkemper, T.
Venue
Epilepsia
Publisher
Wiley
Published
2020-10-11
Volume
61
Issue
12
Pages
2653-2666
ISSN
  • 0013-9580 (ISSN-L)
  • 1528-1167
OpenAlex
W3092011194
Cited by
120
References
4
FWCI
10.37
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.