Lupus Anticoagulant Diagnosis in Patients Receiving Direct Oral FXa Inhibitors at Trough Levels: A Real-life Study
Abstract
Introduction Direct oral factor Xa inhibitors (xabans) induce false positive results for lupus anticoagulant (LA) diagnosis. Consequently, it is suggested not to perform LA testing in xabans patients although it may be useful in selected patients. In this monocentric study, we evaluated xabans impact at trough levels (ie, just before the next intake) on LA diagnosis in treated patients using dilute Russell viper venom time (dRVVT) and two LA sensitive activated partial thromboplastin time (aPTT). Methods Sixty patients receiving rivaroxaban (30) or apixaban (30) were included. Plasma concentrations were measured using specific anti-Xa assays. LA testing was performed using one dRVVT (LAC-Screening ® /Confirm ® ; Siemens) and two LA sensitive aPTT-based assays (Hemosil ® Silica Clotting Time (SCT) Screen/Confirm; Werfen and Dade ® Actin ® Factor Sensitivity FSL/FS (Actin F); Siemens). Results Median [min-max] concentrations were 23 [ Conclusion lupus anticoagulant diagnosis in rivaroxaban and apixaban samples drawn at trough levels remains questionable whenever positive results are obtained. If LA testing in apixaban samples might be useful to rule-out LA using dRVVT and/or aPTT-based assays, the wide majority of rivaroxaban samples would give false positive results.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
All DOACs prolong dRVVT in screening and confirmatory procedures, with rivaroxaban affecting screening more than confirmatory (increasing potential false positives) and opposite apixaban action (increasing potential false negatives).
“all DOACs prolong dRVVT in screening and confirmatory procedures, with rivaroxaban affecting screening more than confirmatory (increasing potential false positives) and opposite apixaban action (increasing potential false negatives) [73,74,75,76,77,78].”
From Lupus Anticoagulant Detection under the Magnifying Glass (2023) · cites this paper as [77]
Cites
Update of the guidelines for lupus anticoagulant detection
PENGO, V., TRIPODI, A., REBER, G., RAND, J. H., ORTEL, T. L., GALLI, M., & DE GROOT, P. G. (2009) · Journal of Thrombosis and Haemostasis · doi:10.1111/j.1538-7836.2009.03555.x · Cited by 1,197 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Lupus Anticoagulant Detection under the Magnifying Glass
Molinari, A. C., Martini, T., Banov, L., Ierardi, A., Leotta, M., Strangio, A., & Santoro, R. C. (2023) · Journal of Clinical Medicine · doi:10.3390/jcm12206654 · Cited by 9 · see citing works
Analytical dilemmas in lupus anticoagulant detection
Moore, G. W. (2023) · Exploration of Immunology · doi:10.37349/ei.2023.00104 · Cited by 5 · see citing works
- Authors
- Gay, J., Duchemin, J., Imarazene, M., Fontenay, M., & Jourdi, G.
- Affiliations
- Hôpital Cochin (FR)
- Service d’Hématologie Biologique AP‐HP Cochin Hospital Paris France
- Inserm (FR)
- Corresponding author
- Jourdi, Georges
- Venue
- International Journal of Laboratory Hematology
- Publisher
- Wiley
- Published
- 2019-09-05
- Volume
- 41
- Issue
- 6
- Pages
- 738-744
- ISSN
- 1751-5521 (ISSN-L)
- 1751-553X
- OpenAlex
- W2972270133
- Cited by
- 15
- References
- 1
- Citations by year
- 2026: 2 · 2025: 1 · 2024: 2 · 2023: 3 · 2022: 3 · 2021: 2 · 2020: 2
- FWCI
- 1.33
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- International Journal of Laboratory Hematology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Rheumatology › Systemic Lupus Erythematosus Research
- Health Sciences › Medicine › Hematology › Blood Coagulation and Thrombosis Mechanisms
- Health Sciences › Medicine › Internal Medicine › Venous Thromboembolism Diagnosis and Management
- Keywords
- lupus anticoagulant, factor Xa inhibitors, rivaroxaban, apixaban, false positives, dilute Russell viper venom time, activated partial thromboplastin time, trough concentration, anti-Xa assay, anticoagulation monitoring
- MeSH terms
- Rivaroxaban, Administration, Oral, Blood Coagulation Tests, False Positive Reactions, Humans, Partial Thromboplastin Time, Pyrazoles, Pyridones, Lupus Coagulation Inhibitor, Antiphospholipid Syndrome, Factor Xa Inhibitors
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review