Analytical dilemmas in lupus anticoagulant detection
Open accessAbstract
Accurate lupus anticoagulant (LA) detection is crucial to antiphospholipid syndrome (APS) diagnosis. Detection is based on LA functional behavior in coagulation assays irrespective of epitope specificity. LA screening tests employ dilute phospholipids to accentuate in vitro inhibition by LAs, although they are not LA-specific and can be elevated by other coagulation abnormalities. Elevated screening tests are reflexed to mixing tests to distinguish between factor deficiency and inhibition. Confirmatory tests with high phospholipid concentration swamp LA to generate shorter clotting times than screening tests, whilst prolongation persists with non-phospholipid-dependent inhibitors. LA heterogeneity means that no single screening test detects every LA and the screen/mix/confirm medley must be applied to at least two assay types, usually dilute Russell’s viper venom time (dRVVT) and an LA-sensitive activated partial thromboplastin time (aPTT). Most laboratories restrict LA testing to these two assays, yet others, such as dilute prothrombin time (dPT), can perform with equal diagnostic efficacy, and additionally detect LA unreactive with dRVVT and aPTT. Converting clotting times to normalized ratios improves assay performance, and practitioners must choose between normal pooled plasma (NPP) clotting time denominators to reflect on-the-day assay performance, or reference interval (RI) mean clotting times to negate the effects of NPP variation. Cut-offs can be generated parametrically from normally distributed data, or different percentiles applied depending on the preferred balance between sensitivity and specificity. Sourcing sufficient donors for accurate cut-off estimations is problematic and transference exercises can be undertaken on low donor numbers. Analytical limitations of mixing tests have led to the adoption of alternative algorithms to the screen/mix/confirm test order, whilst some continue to rigidly apply the latter despite those limitations. Strategies to reduce or eliminate the effects of therapeutic anticoagulation have limitations, whilst the Taipan snake venom time (TSVT) screening test with an ecarin time (ET) confirmatory test is insensitive to vitamin K antagonist (VKA) and direct activated factor X anticoagulation.
AI snapshot
Written from the paper’s full text.
TL;DR
This narrative review examines the analytical dilemmas in laboratory detection of lupus anticoagulants (LA), arguing that reliance on the dRVVT/aPTT pairing, rigid screen/mix/confirm algorithms, and inconsistent normalization and cut-off practices leave clinically significant antibodies undetected. It surveys alternative assays (dPT, ASLA, VLVT, textarin time, TSVT/ET) and testing strategies for anticoagulated patients, concluding that no single algorithmic solution fits all cases.
Key findings
- No LA assay is LA-specific; elevated screening tests only indicate prolonged clotting times, and antibody heterogeneity means no single assay detects every LA, warranting at least two assay types (typically dRVVT plus an LA-sensitive aPTT).
- Other assays detect LA sub-populations unreactive with dRVVT and aPTT: dPT (with recombinant thromboplastin) has been associated with a higher thrombosis association than dRVVT/aPTT in some studies, and TSVT/ET is insensitive to VKA and direct FXa inhibitors because direct FII activation bypasses FXa inhibition.
- Cut-off derivation is contested: ISTH recommends blanket non-parametric 99th percentile cut-offs, while BSH and CLSI permit parametric RIs; the paper notes mean +2SD equals the 97.5th percentile for normally distributed data and the 99th percentile equals mean +2.3SD, so differences are minimal unless distributions are markedly skewed.
- Mixing tests have unacceptably high false-negative rates due to the dilution effect; ISTH now recommends mixing test-specific cut-offs over the index of circulating anticoagulant (Rosner index), and BSH/CLSI permit deviation from the classical algorithm. Percentage correction cut-offs are typically 10–20%.
Methods
- Narrative review of the analytical literature on LA detection, covering the three-step screen/mix/confirm medley, alternative assays, normalization approaches, cut-off statistics, interpretive algorithms, and testing in anticoagulated patients.
- Discusses pre-analytical requirements (platelet count < 10 × 10⁹/L, double centrifugation), normalization denominators (NPP clotting time vs. reference interval mean clotting time), and statistical requirements for cut-offs (minimum 120 normal donor plasmas for statistically valid RIs; as few as 39 for a parametric estimate; 20–40 donors for transference validation, with ≤10% of results outside 95% reference limits permitting adoption of the manufacturer's RI).
- Summarizes guideline positions from ISTH, BSH, and CLSI, and presents suggested testing hierarchies for VKA, DFXaI, DTI, and heparin anticoagulation (Figure 3).
Limitations
- Stated in the paper: no reference plasmas or gold-standard LA-specific assays exist; reagent and analyser variability mean common RIs cannot be applied; mixing tests are not 100% effective and have analytical limitations including the unavoidable dilution effect; sourcing sufficient donors for accurate cut-off estimation is problematic; strategies to reduce or eliminate anticoagulant interference have limitations, and a negative result at each step of the assay hierarchy may not fully exclude LA.
- Evident from the text: this is a narrative review without primary data or systematic search methodology, so its conclusions rest on the author's synthesis of cited literature; the author reports consultancy fees from Technoclone, a reagent manufacturer, which is a potential competing interest.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
0 of 213 cited sources checked · 0 supported · 0 flagged
- Premisereasoning
LA screening tests employ dilute phospholipids to accentuate in vitro inhibition by LAs.
“LA screening tests employ dilute phospholipids to accentuate in vitro inhibition by LAs, although they are not LA-specific and can be elevated by other coagulation abnormalities.”
- Also stated in: § The three-step medley · plain
“the most effective screening tests for LA employ dilute PL to increase competition for limited binding sites, which accentuates the inhibitory effect of any LA present”
Quote in the paperSubstantial claim0 of 2 sources checked- cites [22]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [23]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- Also stated in: § The three-step medley · plain
- Premisereasoning
Converting clotting times to normalized ratios improves assay performance.
“Converting clotting times to normalized ratios improves assay performance”
- Also stated in: § From data to diagnosis · plain
“The solution, which is a recommended practice in all guidelines, is the conversion of screen, mix, and confirm clotting times to normalized ratios [19][20][21].”
Quote in the paperSubstantial claim0 of 3 sources checked- cites [19]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [20]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [21]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- Also stated in: § From data to diagnosis · plain
- Premisecitation
Sourcing sufficient donors for accurate cut-off estimations is problematic.
“Sourcing sufficient donors for accurate cut-off estimations is problematic”
- Also stated in: § Which statistical model for cut-off determination? · plain
“Sourcing such large donor numbers is difficult for most diagnostic facilities”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [88]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- Also stated in: § Which statistical model for cut-off determination? · plain
- Premisereasoning
No single screening test detects every LA.
“LA heterogeneity means that no single screening test detects every LA”
- Also stated in: § Introduction · plain
“no single assay, or assay type, will detect every LA”
Quote in the paperSubstantial claim0 of 3 sources checked- cites [7]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [14]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [16]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- Also stated in: § Introduction · plain
- Interpretationreasoning
The screen/mix/confirm medley must be applied to at least two assay types, usually dRVVT and an LA-sensitive aPTT.
“the screen/mix/confirm medley must be applied to at least two assay types, usually dilute Russell's viper venom time (dRVVT) and an LA-sensitive activated partial thromboplastin time (aPTT)”
Quote in the paperSubstantial claim0 of 3 sources checked- cites [7]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [14]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [16]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- Premisecitation
Transference exercises can be undertaken on low donor numbers.
“transference exercises can be undertaken on low donor numbers”
- Also stated in: § Which statistical model for cut-off determination? · plain
“Validating the transfer requires as few as 20 donors, or up to 40”
Quote in the paperSubstantial claim0 of 4 sources checked- cites [19]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [20]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [21]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [88]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- Also stated in: § Which statistical model for cut-off determination? · plain
- Premisereasoning
Non-phospholipid-dependent inhibitors prolong confirmatory tests to a similar or greater degree as screening tests.
“Non-PL dependent abnormalities, including factor-specific inhibitors, express their elevated clotting times irrespective of PL concentration and can normally be expected to elevate confirmatory tests to a similar or greater degree as that of the screening test.”
Quote in the paperSubstantial claim - Premisereasoning
Confirmatory tests with high phospholipid concentration swamp LA to generate shorter clotting times than screening tests.
“Confirmatory tests with high phospholipid concentration swamp LA to generate shorter clotting times than screening tests”
- Also stated in: § The three-step medley · hedged
“the clotting time is shortened relative to the screening test, often but not always returning into the reference range [14,31,32]”
Quote in the paperSubstantial claim0 of 3 sources checked- cites [14]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [31]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [32]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- Also stated in: § The three-step medley · hedged
- Premisecitation
Most laboratories restrict LA testing to dRVVT and aPTT.
“Most laboratories restrict LA testing to these two assays”
- Also stated in: § The first dilemma-which tests to use, and how many · boosted
“common international practice, that they should be the first station on the diagnostic journey of LA detection [14, 18-21, 28, 33]”
Quote in the paperSubstantial claim0 of 7 sources checked- cites [14]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [18]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [19]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [20]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [21]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [28]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [33]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- Also stated in: § The first dilemma-which tests to use, and how many · boosted
- Premisecitation
TSVT screening with an ET confirmatory test is insensitive to VKA and direct activated factor X anticoagulation.
“the Taipan snake venom time (TSVT) screening test with an ecarin time (ET) confirmatory test is insensitive to vitamin K antagonist (VKA) and direct activated factor X anticoagulation”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [65]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- Premisecitation
Sensitivity to LA is not dictated by PL concentration alone, but also by the composition of the PL in a reagent in terms of the relative amounts of component PLs.
“Sensitivity to LA is not dictated by PL concentration alone, but also the composition of the PL in a reagent in terms of the relative amounts of component PLs [24][25][26].”
Quote in the paperSubstantial claim0 of 3 sources checked- cites [24]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [25]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [26]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- Premisecitation
Most inhibitors persist in elevating the clotting time in a mixing test.
“most inhibitors will persist in elevating the clotting time”
Quote in the paperSubstantial claim0 of 2 sources checked- cites [14]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [30]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- Premisecitation
Only aCL, aβ2GPI, and LA are employed as criteria antibodies in diagnostic practice.
“it is only the triumvirate of anticardiolipin antibodies (aCL), anti-β2 glycoprotein I antibodies (aβ2GPI), and lupus anticoagulants (LA) that are employed as criteria antibodies in diagnostic practice [1,4,7]”
Quote in the paperNot a substantial claim0 of 3 sources checked- cites [1]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [4]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [7]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- Premisecitation
The triple-positive profile has a high risk of thrombosis recurrence or development of a first thrombosis.
“patients or carriers with the triple-positive profile, comprising concomitant positivity for aCL and aβ2GPI of the same isotype, plus LA, have a high risk of thrombosis recurrence or development of a first thrombosis respectively [7][8][9][10]”
Quote in the paperNot a substantial claim0 of 3 sources checked- cites [7]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [8]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [9]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- Premisecitation
aPL antibodies are predominantly directed against phospholipid-binding proteins in complex with negatively-charged phospholipids rather than phospholipid per se.
“the antibodies are predominantly directed against phospholipid (PL)-binding proteins in complex with negatively-charged PLs rather than PL per se [2][3][4]”
Quote in the paperNot a substantial claim0 of 3 sources checked- cites [2]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [3]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [4]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- Premisecitation
Persistent positivity for more than one criteria antibody has a stronger association with APS.
“Persistent positivity for more than one criteria antibody has a stronger association with APS”
Quote in the paperNot a substantial claim0 of 3 sources checked- cites [7]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [8]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [9]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- Premisecitation
Antibody heterogeneity and variability of LA assays create a situation where no single assay or assay type will detect every LA.
“antibody heterogeneity and variability of the assays employed for the detection of LA activity create a situation where no single assay, or assay type, will detect every LA, warranting multiple-assay repertoires in diagnostic practice [7,14,16]”
Quote in the paperSubstantial claim0 of 3 sources checked- cites [7]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [14]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [16]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- Premisecitation
The freeze/thaw process ruptures platelet membranes, releasing further PL into the plasma.
“the freeze/thaw process ruptures platelet membranes, releasing further PL into the plasma”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [28]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- Premisecitation
PL-dependence of an inhibitor is ascertained by recapitulating the screening test with excess PL to overwhelm LA, shortening the clotting time relative to the screening test.
“PL-dependence of the inhibitor is ascertained by recapitulating the screening test but with an excess of PL to overwhelm an LA, thereby shortening the clotting time relative to that of the screening test”
Quote in the paperSubstantial claim0 of 3 sources checked- cites [14]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [31]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [32]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- Premisecitation
LAs exert their in vitro anticoagulant effect by enhancing the binding of target proteins to negatively charged PL, thereby competing with activated coagulation factors for PL-binding sites.
“LAs are reported to exert their in vitro anticoagulant effect by enhancing the binding of target proteins to negatively charged PL, thereby competing with activated coagulation factors for PL-binding sites [22,23].”
Quote in the paperSubstantial claim0 of 2 sources checked- cites [22]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [23]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- Premisenone given
None of the reagents for dRVVT and certain aPTT formulations are LA-specific.
“although reagents for assays such as dRVVT and certain aPTT formulations are described and marketed as LA assays, none are LA-specific”
Quote in the paperNot a substantial claim - Premisecitation
Dilute phospholipid in the screening test accentuates the in vitro inhibitory effect of LA to maximise the chance of an elevated clotting time.
“Dilute PL in the screening test accentuates the in vitro inhibitory effect of LA to maximise the chance of realizing an elevated clotting time.”
Quote in the paperSubstantial claim0 of 2 sources checked- cites [22]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [23]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- Premisereasoning
An elevated screening test in isolation is not diagnostic of LA.
“an elevated screening test in isolation evidences no more than the presence of one or more causes prolonged clotting times to which a given assay is responsive, and is not in itself diagnostic of the presence of an LA”
Quote in the paperSubstantial claim - Premisereasoning
Greater PL contamination increases the possibility of shortening an elevated clotting time into the reference range, causing failure to detect LA.
“The greater the degree of contamination, the greater the possibility of shortening what would have been an elevated clotting time into the reference range, because of additional PL and/or quenching of weaker LA, resulting in failure to detect the antibodies.”
Quote in the paperSubstantial claim - Premisecitation
The confirmatory test recapitulates the screening test in an LA-insensitive modification, usually by concentrating PL to swamp or overwhelm the LA.
“This is undertaken by re-capitulating the screening test in a modification rendering it LA-insensitive, which is usually achieved by concentrating the PL to provide an antigen excess that will sufficiently swamp or overwhelm the LA”
Quote in the paperSubstantial claim0 of 3 sources checked- cites [14]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [31]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [32]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- Premisecitation
LA assay mixing tests are not 100% effective in detecting inhibition.
“As is known for mixing tests with routine PT and aPTT testing, LA assay mixing tests are not 100% effective in detecting inhibition, because like any haemostasis assay, they have analytical limitations [101-103].”
Quote in the paperSubstantial claim0 of 3 sources checked- cites [101]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [102]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [103]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- Premisecitation
Differences in reagent performance can be apparent when using different analyser types.
“differences can be apparent when using different analyser types [38]”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [38]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- Premisecitation
The variable PL composition of routine aPTT reagents results in a continuum of LA-sensitivity.
“The variable PL composition of routine aPTT reagents results in a continuum of LA-sensitivity [14]”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [14]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- Premisecitation
Variations in reagent performance are mainly due to differences in PL composition.
“Variations in reagent performance are mainly due to differences in PL composition [36]”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [36]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- Premisecitation
Venom heterogeneity can affect dRVVT.
“venom heterogeneity can affect dRVVT [39]”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [39]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- Premisecitation
The unavoidable dilution effect in LA mixing tests can lead to false-negatives.
“Principal amongst them is the unavoidable dilution effect that can lead to false-negatives, but other factors also contribute to variable reliability of mixing tests, such as reagent sensitivity and specificity, variability in NPP quality and suitability, (i.e. an NPP with a short clotting time requires more potent LA to prolong the result beyond the cut-off), and interpretive inconsistencies [20,”
Quote in the paperSubstantial claim0 of 3 sources checked- cites [20]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [76]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [96]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- Premisecitation
External quality assurance agencies report false-negative mixing tests as a common cause of misclassification of weaker LA.
“and external quality assurance agencies report false-negative mixing tests as a common cause of misclassification of weaker LA [36,104,107].”
Quote in the paperSubstantial claim0 of 3 sources checked- cites [36]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [104]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [107]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- Premisereasoning
Non-PL dependent abnormalities express elevated clotting times irrespective of PL concentration and can normally be expected to elevate confirmatory tests to a similar or greater degree as the screening test.
“Non-PL dependent abnormalities, including factor-specific inhibitors, express their elevated clotting times irrespective of PL concentration and can normally be expected to elevate confirmatory tests to a similar or greater degree as that of the screening test.”
Quote in the paperSubstantial claim - Premisecitation
Inhibition by LA-β2GPI complexes arises from their direct binding to FV, which impedes FXa-dependent activation of FV.
“inhibition by LA-β2GPI complexes arises from their direct binding to FV, which impedes FXa-dependent activation of FV [15]”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [15]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- Premisecitation
Pairing dRVVT with a suitable aPTT has high detection rates.
“The wealth of evidence that pairing dRVVT with a suitable aPTT has high detection rates validates recommendations in all guidelines”
Quote in the paperSubstantial claim0 of 7 sources checked- cites [14]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [18]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [19]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [20]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [21]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [28]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [33]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- Premisecitation
Between-reagent variation of dRVVT and aPTT preparations from different manufacturers can result in some LA being detected by one manufacturing source but not another.
“there is a between-reagent variation of dRVVT and aPTT preparations from different manufacturers, particularly aPTT, which can result in some LA being detected by the reagent for a particular assay type from one manufacturing source but not another [35][36][37][38][39][40][41][42]”
Quote in the paperSubstantial claim0 of 8 sources checked- cites [35]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [36]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [37]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [38]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [39]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [40]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [41]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [42]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- Premisenone given
Few routine aPTT reagents contain diluted PL.
“few routine reagents contain diluted PL”
Quote in the paperSubstantial claim - Premisecitation
Prothrombin-directed LA competes with factor Xa for PL-binding sites.
“prothrombin-directed LA competes with factor (F) Xa for PL-binding sites”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [15]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- Premisecitation
By concentrating PL, the clotting time is shortened relative to the screening test, often but not always returning into the reference range.
“By doing so, the clotting time is shortened relative to the screening test, often but not always returning into the reference range [14,31,32].”
Quote in the paperSubstantial claim0 of 3 sources checked- cites [14]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [31]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [32]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- Premisecitation
Integrated testing detects weaker antibodies where clotting time elevation above baseline is insufficient to exceed cut-off but screen/confirm discordance reveals LA.
“Integrated testing has additional value in that it detects weaker antibodies where clotting time elevation above a patient's baseline is insufficient to exceed the cut-off but screen and confirm discordance reveals the LA [113][114][115].”
Quote in the paperSubstantial claim0 of 3 sources checked- cites [113]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [114]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [115]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- Premisecitation
In more complex cases, performing both screen and confirm assays on 1:1 mixes with NPP further improves specificity by distinguishing potent LA, LA + concomitant abnormality, and non-LA abnormality.
“In more complex cases, performing both screen and confirm assays on 1:1 mixes with NPP further improves specificity because it aids in distinguishing between potent LA, LA + concomitant abnormality, and non-LA abnormality [14,19,35,73,109,110].”
Quote in the paperSubstantial claim0 of 3 sources checked- cites [14]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [19]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [35]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- Premisecitation
Assays with innately higher specificity tend to require mixing tests less often to conclude presence of LA.
“Assays with innately higher specificity tend to require mixing tests less often to conclude the presence of an LA [80,111].”
Quote in the paperNot a substantial claim0 of 2 sources checked- cites [80]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [111]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- Interpretationreasoning
A normal confirmatory test result is essential in the decision to omit the mixing test because it excludes assay-specific interferences or causes of an elevated clotting time.
“The normal confirmatory test result is essential in the decision to omit the mixing test because it excludes assay-specific -interferences or -causes of an elevated clotting time.”
Quote in the paperSubstantial claim - Premisecitation
VKA anticoagulation affects all LA assays to some degree, with the exceptions of textarin time, TSVT and ET.
“VKA anticoagulation affects all LA assays to some degree, with the exceptions of textarin time, TSVT and ET [18,47,70].”
Quote in the paperNot a substantial claim0 of 3 sources checked- cites [18]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [47]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [70]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- Premisecitation
The TSVT and ET pairing has been validated for use in non-anticoagulated patients and those anticoagulated with VKAs and DFXaIs.
“The TSVT and ET pairing has been recently validated for use in non-anticoagulated patients and those anticoagulated with VKAs and DFXaIs (see later section on direct oral anticoagulants (DOACs)) in a large, international, multi-center study published under the auspices of the ISTH Scientific and Standardization Committee subcommittee on LA/aPL [70].”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [70]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- Interpretationreasoning
Mixing tests are valuable in the iterative algorithm when other causes of elevated clotting times are suspected because NPP corrects factor deficiencies and permits LA to manifest if limitations overcome.
“Mixing tests are valuable in the iterative algorithm when other causes of elevated clotting times are suspected or known to be present as the NPP will commonly correct factor deficiencies and permit any LA to manifest if mixing test limitations are overcome.”
Quote in the paperSubstantial claim - Interpretationnone given
A normal routine coagulation screen (with LA-insensitive aPTT) and confirmation that the patient is not anticoagulated suffice to exclude non-LA causes of elevated LA screening tests.
“A normal routine coagulation screen, which employs an LA-insensitive aPTT, and confirmation that the patient is not anticoagulated, suffice to exclude non-LA causes of elevated LA screening tests.”
Quote in the paperNot a substantial claim - Premisecitation
A mixing test-specific cut-off, ideally expressed as a normalized ratio and not the raw clotting time, is more sensitive to LA-induced inhibition than ICA.
“The index of circulating anticoagulant (ICA) calculation, or Rosner index, has been widely used for interpreting LA assay mixing tests [90,[94][95][96], but recent studies have demonstrated that a mixing test-specific cut-off, ideally expressed as a normalized ratio and not the raw clotting time, is more sensitive to LA-induced inhibition than ICA [97][98][99].”
Quote in the paperSubstantial claim0 of 3 sources checked- cites [97]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [98]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [99]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- Premisecitation
For most patients with other causes of elevated clotting times excluded, demonstrating PL-dependence of an elevated screening test is sufficient to conclude presence of LA.
“For most patients among whom other causes of elevated clotting times have been excluded, demonstrating PL-dependence of an elevated screening test is sufficient to conclude the presence of an LA because the mixing test is not required to distinguish between the inhibitor and factor deficiency [20,103,104,110,111].”
Quote in the paperSubstantial claim0 of 3 sources checked- cites [20]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [103]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [104]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- Interpretationnone given
The LA cofactor effect is inevitably undetectable in integrated testing.
“The relatively rare phenomenon of the LA cofactor effect, the paradoxical finding of greater prolongation of the screening test clotting time in the mixing test than when tested undiluted, is inevitably undetectable in integrated testing.”
Quote in the paperSubstantial claim - Premisecitation
All anticoagulants interfere with at least some coagulation assays used for LA detection.
“All anticoagulants interfere with at least some coagulation assays used for LA detection.”
Quote in the paperSubstantial claim0 of 3 sources checked- cites [14]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [16]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [17]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- Premisecitation
DTIs (dabigatran, argatroban, bivalirudin) interfere with every LA assay in a dose-dependent manner.
“DTIs (dabigatran, argatroban, bivalirudin) interfere with every LA assay in a dose-dependent manner [70,128,[138][139][140].”
Quote in the paperSubstantial claim0 of 3 sources checked- cites [70]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [128]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [138]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- Interpretationnone given
Functional detection of heterogeneous antibodies necessitates the use of a battery of clotting-based assays that are inevitably compromised by other causes of altered clotting times.
“Functional detection of heterogeneous antibodies necessitates the use of a battery of clotting-based assays that are inevitably compromised by other causes of altered clotting times.”
Quote in the paperSubstantial claim - Premisecitation
Commercial dPT and VLVT reagents, most dRVVT reagents, and some aPTT reagents specifically formulated for LA detection contain heparin-neutralizing agents capable of quenching UFH and LMWH to within or just above therapeutic ranges, commonly up to 0.8-1.0 IU/mL.
“In response, commercial dPT and VLVT reagents, most dRVVT reagents, and some aPTT reagents specifically formulated for LA detection, contain heparin-neutralizing agents capable of quenching UFH and LMWH to within or just above therapeutic ranges, commonly up to 0.8-1.0IU/mL [14,16,17].”
Quote in the paperSubstantial claim0 of 3 sources checked- cites [14]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [16]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [17]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- Premisecitation
All screen and confirm assays are affected by UFH, with the sole exception being ET.
“All screen and confirm assays are affected by UFH, with the sole exception being ET, because steric hindrance prevents the heparin-antithrombin complex from inhibiting meizothrombin, the product of ecarin-activated prothrombin [70,132,133].”
Quote in the paperSubstantial claim0 of 3 sources checked- cites [70]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [132]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [133]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- Premisecitation
DFXaI (rivaroxaban, apixaban, edoxaban) interfere with all LA assays except textarin time, TSVT, and ET.
“DFXaI (rivaroxaban, apixaban, edoxaban) interfere with all LA assays except textarin time, TSVT, and ET, because direct FII activation bypasses inhibition of FXa [70,128,137,141,142].”
Quote in the paperSubstantial claim0 of 3 sources checked- cites [70]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [128]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [137]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- May combine two claims. 33
- Classified as probably not a substantial claim. 17
May combine two claims.
PremisecitationdPT can perform with equal diagnostic efficacy to dRVVT/aPTT and can detect LA unreactive with dRVVT and aPTT.
“others, such as dilute prothrombin time (dPT), can perform with equal diagnostic efficacy, and additionally detect LA unreactive with dRVVT and aPTT”
- Also stated in: § The other LA assays · hedged
“some studies have evidenced that LAs detected with dPTs employing recombinant thromboplastin exhibit a higher association with thrombosis than those detected by dRVVT and aPTT [58,62]”
Quote in the paperSubstantial claim0 of 2 sources checked- cites [58]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [62]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- Also stated in: § The other LA assays · hedged
Probably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
PremisecitationCut-offs can be generated parametrically from normally distributed data, or different percentiles applied depending on the preferred balance between sensitivity and specificity.
“Cut-offs can be generated parametrically from normally distributed data, or different percentiles applied depending on the preferred balance between sensitivity and specificity.”
Quote in the paperNot a substantial claim0 of 2 sources checked- cites [19]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [88]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
Classified as probably not a substantial claim.
PremisecitationLA detection is based on LA functional behavior in coagulation assays irrespective of epitope specificity.
“Detection is based on LA functional behavior in coagulation assays irrespective of epitope specificity.”
- Also stated in: § Introduction · plain
“LAs are defined through functional properties irrespective of epitope specificities [4,14].”
Quote in the paperSubstantial claim0 of 2 sources checked- cites [4]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [14]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- Also stated in: § Introduction · plain
May combine two claims.
PremisereasoningLA screening tests are not LA-specific and can be elevated by other coagulation abnormalities.
“although they are not LA-specific and can be elevated by other coagulation abnormalities”
- Also stated in: § The three-step medley · plain
“none are LA-specific”
Quote in the paperSubstantial claim- Also stated in: § The three-step medley · plain
May combine two claims.
PremisecitationNPP clotting time denominators reflect on-the-day assay performance, whereas RI mean clotting time denominators negate the effects of NPP variation.
“practitioners must choose between normal pooled plasma (NPP) clotting time denominators to reflect on-the-day assay performance, or reference interval (RI) mean clotting times to negate the effects of NPP variation”
Quote in the paperSubstantial claim0 of 9 sources checked- cites [14]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [20]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [28]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [70]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [75]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [77]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [80]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [81]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [82]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
Probably not a substantial claim: may not pass S4 (based).
Premisenone givenAnalytical limitations of mixing tests have led to adoption of alternative algorithms to the screen/mix/confirm test order.
“Analytical limitations of mixing tests have led to the adoption of alternative algorithms to the screen/mix/confirm test order”
Quote in the paperNot a substantial claimMay combine two claims.
PremisecitationLA functional activity is mainly attributed to autoantibodies against β2GPI and prothrombin, each separately contributing to overall LA activity.
“LA functional activity is mainly attributed to autoantibodies against β2GPI and prothrombin, each separately contributing to the overall LA activity [14,15].”
Quote in the paperNot a substantial claim0 of 2 sources checked- cites [14]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [15]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
Classified as probably not a substantial claim. May combine two claims.
PremisecitationPlasma filtration through 0.22 μm filters is not recommended as it can generate microparticles and may reduce or remove some coagulation factors.
“plasma filtration through 0.22 µm filters will remove all platelets, but is not recommended as it can also generate microparticles, and additionally, may reduce or remove some coagulation factors [19,20]”
Quote in the paperSubstantial claim0 of 2 sources checked- cites [19]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [20]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
May combine two claims.
PremisecitationPlatelet counts in plasma being tested for LA must be < 10 × 10^9/L, otherwise residual available PL may shorten the clotting time.
“Platelet counts in plasma being tested for LA must be < 10 × 10 9 /L, otherwise the residual available PL may provide sufficient additional binding sites for coagulation factors to shorten the clotting time.”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [27]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
Classified as probably not a substantial claim.
PremisecitationUltracentrifugation is not recommended because the severity of centrifugation conditions can generate PL-containing microparticles.
“ultracentrifugation might appear a tempting alternative, it is not recommended because the severity of centrifugation conditions can generate PL-containing microparticles [19,29]”
Quote in the paperSubstantial claim0 of 2 sources checked- cites [19]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [29]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
Classified as probably not a substantial claim.
PremisecitationLAs are detected by inference based on their behavior in a medley of coagulation assays.
“LAs are detected by inference based on their behavior in a medley of coagulation assays [14,16]”
Quote in the paperSubstantial claim0 of 2 sources checked- cites [14]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [16]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
May combine two claims.
PremisecitationThe combination of elevated screening and mixing tests narrows the interpretation to that of an inhibitor, and the confirmatory test secures the distinction between factor-specific inhibition and factor-non-specific/PL-dependent inhibition of LAs.
“The combination of elevated screening and mixing tests narrows the interpretation to that of an inhibitor, and it is the confirmatory test that then secures the distinction between factor-specific inhibition and the factor-non-specific/PL-dependent inhibition of LAs [14].”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [14]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
Probably not a substantial claim: may not pass S4 (based).
Premisenone givenStrategies to reduce or eliminate the effects of therapeutic anticoagulation have limitations.
“Strategies to reduce or eliminate the effects of therapeutic anticoagulation have limitations”
Quote in the paperNot a substantial claimClassified as probably not a substantial claim.
PremisecitationDouble centrifugation is recommended practice to achieve the requisite platelet count reduction.
“Recommended practice to achieve the requisite platelet count reduction is double centrifugation”
Quote in the paperSubstantial claim0 of 3 sources checked- cites [19]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [20]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [21]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
Probably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationPersistent isolated LA is reported as a high-risk profile in some recent studies.
“persistent isolated LA is reported as a high-risk profile in some recent studies [11][12][13]”
Quote in the paperNot a substantial claim0 of 3 sources checked- cites [11]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [12]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [13]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
Probably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationAPS is a systemic autoimmune disorder characterized by arterial or venous thrombosis and/or pregnancy morbidity in patients with persistent aPL.
“Antiphospholipid syndrome (APS) is a systemic autoimmune disorder characterized by the non-specific clinical manifestations of arterial or venous thrombosis and/or pregnancy morbidity in patients with persistent antiphospholipid antibodies (aPL) [1].”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [1]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
May combine two claims.
PremisereasoningThe primary roles of aPTT reagents designed for routine coagulation screening are detection of factor deficiencies and heparin monitoring, and the PL component is not necessarily optimized for LA detection.
“The primary roles of aPTT reagents designed for routine coagulation screening are detection of factor deficiencies and heparin monitoring, and the PL component is not necessarily optimized for LA detection.”
Quote in the paperSubstantial claimMay combine two claims.
PremisecitationOther factors contribute to variable reliability of mixing tests: reagent sensitivity and specificity, variability in NPP quality and suitability, and interpretive inconsistencies.
“Principal amongst them is the unavoidable dilution effect that can lead to false-negatives, but other factors also contribute to variable reliability of mixing tests, such as reagent sensitivity and specificity, variability in NPP quality and suitability, (i.e. an NPP with a short clotting time requires more potent LA to prolong the result beyond the cut-off), and interpretive inconsistencies [20,”
Quote in the paperSubstantial claim0 of 3 sources checked- cites [20]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [76]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [96]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
May combine two claims.
InterpretationcitationBecause LA testing does not stop at the screening test, any false-positive screening test will be subjected to the rest of the three-step process, where a false-positive composite interpretation is less likely.
“LA testing does not stop at the screening test, so any false-positive screening test will be subjected to the rest of the three-step process, where a falsepositive interpretation of the composite is less likely [14,20,35]”
Quote in the paperSubstantial claim0 of 3 sources checked- cites [14]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [20]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [35]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
May combine two claims.
PremisecitationOther assays have been shown to detect small LA sub-populations that do not manifest in dRVVT and aPTT, and can increase detection rates.
“other assays have been shown to detect small LA sub-populations that do not manifest in dRVVT and aPTT, and can increase detection rates [43][44][45][46][47][48][49][50]”
Quote in the paperSubstantial claim0 of 8 sources checked- cites [43]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [44]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [45]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [46]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [47]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [48]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [49]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [50]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
Probably not a substantial claim: may not pass S4 (based).
Premisenone givenEvery intrinsic pathway-based LA assay is no more than a modified aPTT.
“Every intrinsic pathway-based LA assay is no more than a modified aPTT”
Quote in the paperNot a substantial claimMay combine two claims.
InterpretationreasoningThe low and high PL screen and confirm assay design remains effective for prothrombin-directed and LA-β2GPI antibodies because their inhibition occurs only at limiting PL concentrations, and not at high PL concentrations.
“the low and high PL screen and confirm assay design remains effective for these antibodies because their inhibition occurs only at limiting PL concentrations, and not at high PL concentrations”
Quote in the paperSubstantial claimProbably not a substantial claim: may not pass S2 (checkable).
InterpretationreasoningLA testing is best done with an aPTT reagent specifically formulated for LA detection, even if it means having a separate reagent for routine coagulation screening.
“LA testing is best done with an aPTT reagent specifically formulated for LA detection, even if it means having a separate reagent for routine coagulation screening.”
Quote in the paperNot a substantial claimMay combine two claims.
InterpretationreasoningA factor deficiency or natural statistical outlier would generate an elevated screening test, yet the mixing test would be normal and the confirmatory test similarly prolonged, so a false-positive composite interpretation would not ensue.
“a factor deficiency or natural statistical outlier would generate an elevated screening test result, yet the mixing test would be normal and the confirmatory test similarly prolonged, so a false-positive composite interpretation would not ensue”
Quote in the paperSubstantial claimMay combine two claims.
PremisecitationIn situations with elevated confirmatory test, a mixing test can correct factor deficiencies and effects of some anticoagulants, and can make PL-dependence more obvious by diluting antibody titer.
“In such situations, a mixing test can be invaluable as it will correct factor deficiencies and the effects of some anticoagulants, and can make PL-dependence more obvious by diluting the antibody titer [103,109].”
Quote in the paperSubstantial claim0 of 2 sources checked- cites [103]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [109]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
May combine two claims.
InterpretationreasoningThe iterative algorithm permits conclusion of LA if confirm ratio significantly corrects elevated screen ratio and confirm ratio is normal, with normal coagulation screening and no anticoagulation.
“Given the analytical inconsistencies of mixing tests, the iterative algorithm permits the conclusion of the presence of an LA if the confirm ratio significantly corrects the elevated screen ratio and the confirm ratio is normal, the latter excluding other causes of elevated clotting times in conjunction with normal coagulation screening and confirmation that the patient is not anticoagulated.”
Quote in the paperSubstantial claimMay combine two claims.
InterpretationreasoningPerforming a mixing test increases specificity, especially when other or co-existent abnormalities are suspected; it also increases diagnostic certainty in straightforward cases.
“Performing a mixing test increases specificity, especially in situations where other or co-existent abnormalities are suspected, but they also increase diagnostic certainty and confidence in otherwise straightforward cases if desired.”
Quote in the paperSubstantial claimClassified as probably not a substantial claim.
PremisecitationThe ISTH guideline recommends performance of both mixing test and confirmatory test in response to elevated screening test instead of strict sequential testing.
“In acknowledgment of the occurrence of false-negative mixing tests, the ISTH guideline recommends performance of both mixing test and confirmatory test in response to the finding of an elevated screening test in place of strict adherence to sequential testing [21].”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [21]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
May combine two claims.
InterpretationcitationIntegrated testing oversimplifies LA detection in some patients, particularly where there are co-existing abnormalities; there is no one-size-fits-all algorithmic solution to LA testing.
“Whilst this is certainly true for some patients, integrated testing oversimplifies LA detection in others, particularly where there are co-existing abnormalities, emphasizing that there is not a one-size-fits-all algorithmic solution to LA testing [14,103].”
Quote in the paperSubstantial claim0 of 2 sources checked- cites [14]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [103]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
May combine two claims.
PremisecitationIn VKA anticoagulated patients, an elevated screen mixing test accompanied by significant discordance with a normal confirm mixing test is diagnostic for the presence of an LA, but negative mixing tests do not exclude an LA due to the dilution effect.
“In VKA anticoagulated patients, an elevated screen mixing test accompanied by significant discordance with a normal confirm mixing test is diagnostic for the presence of an LA, but crucially, negative mixing tests do not exclude an LA due to the dilution effect [14,19,20,73].”
Quote in the paperSubstantial claim0 of 3 sources checked- cites [14]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [19]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [20]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
Probably not a substantial claim: may not pass S2 (checkable).
PremisecitationAttempting to detect LA in anticoagulated patients can be valuable for decisions regarding therapy duration and choice of type of anticoagulant in view of the aPL profile.
“However, attempting to detect LA in anticoagulated patients can be valuable for decisions regarding therapy duration and choice of type of anticoagulant in view of the aPL profile [17,123,124].”
Quote in the paperNot a substantial claim0 of 3 sources checked- cites [17]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [123]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [124]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
May combine two claims.
PremisecitationSome potent LAs give concordant screen and confirm results on undiluted plasma; dilution in mixing test permits PL-dependence to manifest, and integrated testing returns a false-negative result.
“Some LAs are so potent that testing on undiluted plasma gives concordant screen and confirm results, whereupon dilution of antibody potency in the mixing test permits PL-dependence to manifest, and integrated testing returns a false-negative result [109].”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [109]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
May combine two claims.
InterpretationcitationIntegrated testing improves detection of weaker antibodies but oversimplifies complex cases unless a mixing step is included.
“Integrated testing immediately assesses for phospholipid dependence irrespective of whether the screening test is elevated or not, which improves the detection of weaker antibodies, but oversimplifies more complex cases unless a mixing step is included”
Quote in the paperSubstantial claimMay combine two claims.
PremisecitationAn elevated confirmatory test in the scenario of elevated screening test can be due to a co-existing abnormality, such as a mild factor deficiency, undisclosed anticoagulation, or an LA sufficiently potent to resist high PL concentration confirm reagent.
“An elevated confirmatory test in this scenario can be due to a co-existing abnormality, such as a mild factor deficiency missed in routine coagulation screening, undisclosed anticoagulation, or an LA sufficiently potent to partially or completely resist the overwhelming effect of a high PL concentration confirm reagent [20,31,103,108,109].”
Quote in the paperSubstantial claim0 of 3 sources checked- cites [20]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [31]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [103]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
Classified as probably not a substantial claim.
PremisecitationTesting for LA in anticoagulated patients is largely discouraged.
“This complicates LA testing and increases the possibility of false positive and negative interpretations, and testing for LA in anticoagulated patients is largely discouraged [17,[19][20][21].”
Quote in the paperSubstantial claim0 of 3 sources checked- cites [17]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [19]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [20]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
Classified as probably not a substantial claim.
PremisecitationThe most recently published expert guideline, from the ISTH, recommends mixing test-specific cut-off over ICA because it produces less false-negative mixing test results.
“The most recently published expert guideline, from the ISTH, recommends mixing test-specific cut-off over ICA because it produces less false-negative mixing test results [21].”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [21]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
May combine two claims.
PremisecitationApplying integrated testing with a higher normalized LA ratio cut-off than for non-anticoagulated patients improves specificity but reduces sensitivity.
“Applying integrated testing with a higher normalized LA ratio cut-off than for non-anticoagulated patients has been shown to improve specificity, but with a reduction in sensitivity [130,131].”
Quote in the paperSubstantial claim0 of 2 sources checked- cites [130]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [131]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
May combine two claims.
InterpretationreasoningMixing tests can be invaluable where other abnormalities are present, but a hindrance when design limitations of the mixing test principle give misleading information.
“There are variations on how to apply the composite testing model, particularly regarding the place of mixing tests, which can be invaluable where other abnormalities are present, but a hindrance when design limitations of the mixing test principle give misleading information.”
Quote in the paperNot a substantial claimMay combine two claims.
PremisecitationIncreased C-reactive protein can interfere with aPTT-based assays, giving rise to false-positive results, whilst elevated FVIII and fibrinogen can shorten aPTT, giving rise to the potential for false-negatives.
“The increased C-reactive protein can interfere with aPTT-based assays, giving rise to false-positive results [162], whilst the elevated FVIII and fibrinogen [20,21,163,164] can shorten aPTT, giving rise to the potential for false-negatives.”
Quote in the paperSubstantial claim0 of 3 sources checked- cites [162]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [20]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [21]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
May combine two claims.
InterpretationreasoningApplying composite testing to each assay type improves specificity but interpretation can be challenging when trying to unravel the possible presence of an LA where there are other abnormalities that may mask, mimic, or co-exist.
“Applying composite testing to each assay type improves specificity but interpretation can be challenging when trying to unravel the possible presence of an LA where there are other abnormalities that may mask, mimic, or co-exist.”
Quote in the paperSubstantial claimMay combine two claims.
PremisecitationIf heparin is the only cause of an elevated clotting time, screen and confirm results are normally concordant and the mixing test may or may not be elevated depending on dose and reagent heparin sensitivity, and interpretation of the composite would not suggest the presence of an LA.
“If heparin is the only cause of an elevated clotting time, screen and confirm results are normally concordant and the mixing test may or may not be elevated depending on dose and reagent heparin sensitivity, and interpretation of the composite would not suggest the presence of an LA [134].”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [134]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
May combine two claims.
PremisecitationIf the screen is elevated but the confirm is normal, and discordance significant, the normal confirm result evidences quenching of the heparin by the neutraliser, and of the LA by the confirm reagent.
“If the screen is elevated but the confirm is normal, and discordance significant, the normal confirm result evidences quenching of the heparin by the neutraliser, and of the LA by the confirm reagent [14,16,20].”
Quote in the paperSubstantial claim0 of 3 sources checked- cites [14]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [16]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [20]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
May combine two claims.
InterpretationreasoningAntibody heterogeneity and reagent variability affect all assays, including the favored dRVVT and aPTT pairing, yet overreliance on two familiar and well-performing assays solves some problems but ignores others.
“Antibody heterogeneity and reagent variability affect all assays, including the favored dRVVT and aPTT pairing, yet overreliance on two familiar and well-performing assays solves some problems but ignores others.”
Quote in the paperSubstantial claimMay combine two claims.
PremisecitationActivated charcoal adsorption products are reported to be effective in facilitating reliable dRVVT and aPTT analysis, but less beneficial for dPT.
“They are reported to be effective in facilitating reliable dRVVT and aPTT analysis [149-153], but less beneficial for dPT [154].”
Quote in the paperSubstantial claim0 of 6 sources checked- cites [149]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [150]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [151]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [152]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [153]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [154]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
May combine two claims.
PremisecitationTransient LAs in response to infections are well described, whilst infections are reported as a common precipitating factor of catastrophic APS in patients with existing APS.
“Transient LAs in response to infections are well described [169-171], whilst infections are reported as a common precipitating factor of catastrophic APS in patients with existing APS [172].”
Quote in the paperNot a substantial claim0 of 4 sources checked- cites [169]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [170]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [171]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [172]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
Classified as probably not a substantial claim. May combine two claims.
PremisecitationRecent recommendations state that LA testing on patients receiving DOAC should not be done unless an adsorption procedure has been performed, and that the adsorption should only be done on samples from patients known to be DOAC anticoagulated.
“Consequently, the recent recommendations state that LA testing on patients receiving DOAC should not be done unless an adsorption procedure has been performed, and that the adsorption should only be done on samples from patients known to be DOAC anticoagulated [17,155].”
Quote in the paperSubstantial claim0 of 2 sources checked- cites [17]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [155]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- Rests on an assumption: DOACs and parenteral DTIs are unaffected by heparin neutralizers.
May combine two claims.
PremisecitationFalse-positive interpretations due to greater elevation of screen results compared to confirm results have been reported for dRVVT and aPTT-based assays with DTI and DFXaI, and for TSVT/ET with DTI.
“False-positive interpretations due to greater elevation of screen results compared to confirm results have been reported for dRVVT and aPTT-based assays with DTI and DFXaI [116, 137, 138, 141, 142], and for TSVT/ET with DTI [70].”
Quote in the paperSubstantial claim0 of 3 sources checked- cites [116]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [137]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [138]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
The authors state this as an assumption.
When interpreting coagulation assays for LA, no other causes of abnormal clotting times are present.
“interpretation is necessarily based on the assumption that no other causes of abnormal clotting times are present, which is not always the case”
The paper relies on this without support.
Normal pooled plasma replenishes deficient clotting factors and corrects factor deficiencies in mixing tests.
“The theory behind such mixing tests is that the NPP will replenish any deficient clotting factors such that the mixing test result corrects back to normality”
The paper relies on this without support.
DOACs and parenteral DTIs are unaffected by heparin neutralizers.
“The DOACs (dabigatran and the three DFXaIs) and parenteral DTI are unaffected by heparin neutralizers.”
The paper relies on this without support.
Accurate LA detection is crucial to effective diagnosis and management of APS.
“Accurate LA detection is crucial to effective diagnosis and management of APS but it remains hampered by the lack of specific assays.”
Cites
McNeil, H. P., Simpson, R. J., Chesterman, C. N., & Krilis, S. A. (1990) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.87.11.4120 · Cited by 1,595 · see citing works
Anticardiolipin antibodies (ACA) directed not to cardiolipin but to a plasma protein cofactor
Galli, M., Barbui, T., Comfurius, P., Maassen, C., Hemker, H. C., Zwaal, R. F. A., Bevers, E. M., Baets, M. H. D., & Vriesman, P. J. C. V. B. (1990) · The Lancet · doi:10.1016/0140-6736(90)91374-j · Cited by 1,266 · see citing works
Update of the guidelines for lupus anticoagulant detection
PENGO, V., TRIPODI, A., REBER, G., RAND, J. H., ORTEL, T. L., GALLI, M., & DE GROOT, P. G. (2009) · Journal of Thrombosis and Haemostasis · doi:10.1111/j.1538-7836.2009.03555.x · Cited by 1,197 · see citing works
Triggers, targets and treatments for thrombosis
Mackman, N. (2008) · Nature · doi:10.1038/nature06797 · Cited by 1,187 · see citing works
Guidelines on the investigation and management of antiphospholipid syndrome
Keeling, D., Mackie, I., Moore, G. W., Greer, I. A., Greaves, M., & British Committee for Standards in Haematology (2012) · British Journal of Haematology · doi:10.1111/j.1365-2141.2012.09037.x · Cited by 740 · see citing works
Self-citationClinical course of high‐risk patients diagnosed with antiphospholipid syndrome
PENGO, V., RUFFATTI, A., LEGNANI, C., GRESELE, P., BARCELLONA, D., ERBA, N., TESTA, S., MARONGIU, F., BISON, E., DENAS, G., et al. (2010) · Journal of Thrombosis and Haemostasis · doi:10.1111/j.1538-7836.2009.03674.x · Cited by 633 · see citing works
A clinical study of the lupus anticoagulant
Schleider, M., Nachman, R. L., Jaffe, E., & Coleman, M. (1976) · Blood · doi:10.1182/blood.v48.4.499.499 · Cited by 469 · see citing works
Pengo, V., Ruffatti, A., Legnani, C., Testa, S., Fierro, T., Marongiu, F., De Micheli, V., Gresele, P., Tonello, M., Ghirarduzzi, A., et al. (2011) · Blood · doi:10.1182/blood-2011-03-340232 · Cited by 465 · see citing works
Devreese, K. M. J., de Groot, P. G., de Laat, B., Erkan, D., Favaloro, E. J., Mackie, I., Martinuzzo, M., Ortel, T. L., Pengo, V., Rand, J. H., et al. (2020) · Journal of Thrombosis and Haemostasis · doi:10.1111/jth.15047 · Cited by 439 · see citing works
A Sensitive Test Demonstrating Lupus Anticoagulant and its Behavioural Patterns
Exner, T., RICKARD, K. A., & KRONENBERG, H. (1978) · British Journal of Haematology · doi:10.1111/j.1365-2141.1978.tb03648.x · Cited by 391 · see citing works
Rodríguez‐Pintó, I., Moitinho, M., Santacreu, I., Shoenfeld, Y., Erkan, D., Espinosa, G., & Cervera, R. (2016) · Autoimmunity Reviews · doi:10.1016/j.autrev.2016.09.010 · Cited by 315 · see citing works
Antiphospholipid antibodies and infections
Asherson, R. A., & Cervera, R. (2003) · Annals of the Rheumatic Diseases · doi:10.1136/ard.62.5.388 · Cited by 282 · see citing works
Triplett, D. A., Brandt, J. T., Kaczor, D. A., et al. (1983) · American Journal of Clinical Pathology · doi:10.1093/ajcp/79.6.678 · Cited by 276 · see citing works
Laboratory criteria for antiphospholipid syndrome: communication from the SSC of the ISTH
Devreese, K. M. J., Ortel, T. L., Pengo, V., & de Laat, B. (2018) · Journal of Thrombosis and Haemostasis · doi:10.1111/jth.13976 · Cited by 269 · see citing works
Kini, R. M., & Koh, C. Y. (2016) · Toxins · doi:10.3390/toxins8100284 · Cited by 192 · see citing works
Detection and Quantitative Evaluation of Lupus Circulating Anticoagulant Activity
Rosner, E., Pauzner, R., Lusky, A., Modan, M., & Many, A. (1987) · Thrombosis and Haemostasis · doi:10.1055/s-0038-1651083 · Cited by 188 · see citing works
Ruffatti, A., Del Ross, T., Ciprian, M., Bertero, M. T., Salvatore, S., Scarpato, S., Montecucco, C., Rossi, S., Caramaschi, P., Biasi, D., et al. (2011) · Annals of the Rheumatic Diseases · doi:10.1136/ard.2010.142042 · Cited by 184 · see citing works
Galli, M., Borrelli, G., Jacobsen, E. M., Marfisi, R. M., Finazzi, G., Marchioli, R., Wisloff, F., Marziali, S., Morboeuf, O., & Barbui, T. (2007) · Blood · doi:10.1182/blood-2007-01-066043 · Cited by 170 · see citing works
Zuily, S., Cohen, H., Isenberg, D. A., Woller, S. C., Crowther, M. A., Dufrost, V., Wahl, D. G., Doré, C. J., Cuker, A. C., Carrier, M., et al. (2020) · Journal of Thrombosis and Haemostasis · doi:10.1111/jth.14935 · Cited by 156 · see citing works
International Normalized Ratios (INR): the first 20 years
Poller, L. (2004) · Journal of Thrombosis and Haemostasis · doi:10.1111/j.1538-7836.2004.00775.x · Cited by 154 · see citing works
Recent Guidelines and Recommendations for Laboratory Detection of Lupus Anticoagulants
Moore, G. (2014) · Seminars in Thrombosis and Hemostasis · doi:10.1055/s-0033-1364185 · Cited by 148 · see citing works
Self-citationThe Ecarin Clotting Time, a Universal Method to Quantify Direct Thrombin Inhibitors
Nowak, G. (2003) · Pathophysiology of Haemostasis and Thrombosis · doi:10.1159/000081505 · Cited by 146 · see citing works
Tripodi, A., Cohen, H., & Devreese, K. M. J. (2020) · Journal of Thrombosis and Haemostasis · doi:10.1111/jth.14846 · Cited by 143 · see citing works
Lupus Anticoagulant Activity Is Frequently Dependent on the Presence of β2-Glycoprotein I
Oostin, J. D., Derksen, R. H. W. M., Entjes, H. T. I., Bouma, B. N., & de Groot, P. G. (1992) · Thrombosis and Haemostasis · doi:10.1055/s-0038-1648480 · Cited by 143 · see citing works
Mustonen, P., Lehtonen, K. V., Javela, K., & Puurunen, M. (2014) · Lupus · doi:10.1177/0961203314545410 · Cited by 127 · see citing works
Schouwers, S. M. E., Delanghe, J. R., & Devreese, K. M. J. (2010) · Thrombosis Research · doi:10.1016/j.thromres.2009.09.001 · Cited by 115 · see citing works
Bonar, R. A., Favaloro, E. J., Mohammed, S., et al. (2015) · Pathology · doi:10.1016/j.pathol.2015.11.025 · Cited by 110 · see citing works
The Textarin/Ecarin Ratio: A Confirmatory Test for Lupus Anticoagulants
Triplett, D. A., Stocker, K. F., Unger, G. A., & Barna, L. K. (1993) · Thrombosis and Haemostasis · doi:10.1055/s-0038-1649701 · Cited by 110 · see citing works
One‐stage vs. chromogenic assays in haemophilia A
Potgieter, J., Damgaard, M., & Hillarp, A. (2015) · European Journal Of Haematology · doi:10.1111/ejh.12500 · Cited by 108 · see citing works
Jennings, I., Kitchen, S., Woods, T. A. L., Preston, F. E., & Greaves, M. (1997) · Thrombosis and Haemostasis · doi:10.1055/s-0038-1656080 · Cited by 103 · see citing works
Wittevrongel, C., Vanrusselt, M., Hoylaerts, M., Vermylen, J., & Arnout, J. (1998) · Thrombosis and Haemostasis · doi:10.1055/s-0037-1614224 · Cited by 95 · see citing works
Barbhaiya, M., Zuily, S., Ahmadzadeh, Y., Amigo, M., Avčin, T., Bertolaccini, M. L., Branch, D. W., de Jesús, G. R., Devreese, K. M. J., Francès, C., et al. (2020) · Arthritis Care & Research · doi:10.1002/acr.24520 · Cited by 94 · see citing works
Kelsey, P. R., Stevenson, K. J., & Poller, L. (1984) · Thrombosis and Haemostasis · doi:10.1055/s-0038-1661166 · Cited by 91 · see citing works
Martinuzzo, M. E., Barrera, L. H., D 'Adamo, M. A., Otaso, J. C., Gimenez, M. I., & Oyhamburu, J. (2014) · International Journal of Laboratory Hematology · doi:10.1111/ijlh.12138 · Cited by 91 · see citing works
Arachchillage, D. J., Gomez, K., Alikhan, R., Anderson, J. A. M., Lester, W., Laffan, M., & British Society for Haematology Haemostasis and Thrombosis Taskforce (2020) · British Journal of Haematology · doi:10.1111/bjh.16308 · Cited by 88 · see citing works
Simple method for removing DOACs from plasma samples
Exner, T., Michalopoulos, N., Pearce, J., et al. (2018) · Thrombosis Research · doi:10.1016/j.thromres.2018.01.047 · Cited by 81 · see citing works
Factor XIII deficiency diagnosis: Challenges and tools
Karimi, M., Peyvandi, F., Naderi, M., et al. (2017) · International Journal of Laboratory Hematology · doi:10.1111/ijlh.12756 · Cited by 80 · see citing works
Orellana, D., & Kershaw, G. (2013) · Seminars in Thrombosis and Hemostasis · doi:10.1055/s-0033-1336832 · Cited by 76 · see citing works
Mackie, I. J., Purdy, G., Machin, S. J., & Lawrie, A. S. (1999) · Thrombosis and Haemostasis · doi:10.1055/s-0037-1614567 · Cited by 75 · see citing works
Platton, S., & Hunt, C. (2019) · International Journal of Laboratory Hematology · doi:10.1111/ijlh.12950 · Cited by 74 · see citing works
Cooper, P. C., Pavlova, A., Moore, G. W., et al. (2020) · Journal of Thrombosis and Haemostasis · doi:10.1111/jth.14667 · Cited by 71 · see citing works
Self-citationMarlar, R. A., Gausman, J. N., Tsuda, H., et al. (2021) · Journal of Thrombosis and Haemostasis · doi:10.1111/jth.15109 · Cited by 71 · see citing works
Arnout, J., Vanrusselt, M., Huybrechts, E., & Vermylen, J. (1994) · British Journal of Haematology · doi:10.1111/j.1365-2141.1994.tb04876.x · Cited by 68 · see citing works
Mixing studies in lupus anticoagulant testing are required at least in some type of samples
Devreese, K. M. J., & de Laat, B. (2015) · Journal of Thrombosis and Haemostasis · doi:10.1111/jth.13020 · Cited by 63 · see citing works
Arachchillage, D. J., Mackie, I. J., Efthymiou, M., Isenberg, D. A., Machin, S. J., & Cohen, H. (2015) · Journal of Thrombosis and Haemostasis · doi:10.1111/jth.12917 · Cited by 60 · see citing works
The Taipan snake venom time: a new test for lupus anticoagulant.
Rooney, A. M., McNally, T., Mackie, I. J., & Machin, S. J. (1994) · Journal of Clinical Pathology · doi:10.1136/jcp.47.6.497 · Cited by 60 · see citing works
Marked variation in antiphospholipid antibodies during pregnancy: relationships to pregnancy outcome
Topping, J. (1999) · Human Reproduction · doi:10.1093/humrep/14.1.224 · Cited by 57 · see citing works
Fritsma, G. A., Dembitzer, F. R., Randhawa, A., Marques, M. B., Cott, E. M. V., Funk, D. M. A., & Peerschke, E. I. B. (2012) · American Journal of Clinical Pathology · doi:10.1309/ajcp3j1zkybfqxjm · Cited by 56 · see citing works
Gardiner, C., Mackie, I. J., Malía, R. G., Jones, D. W., Winter, M. R., Leeming, D., Taberner, D. A., Machin, S. J., & Greaves, M. (2000) · British Journal of Haematology · doi:10.1046/j.1365-2141.2000.02466.x · Cited by 55 · see citing works
Lupus-anticoagulant testing at NOAC trough levels
Ratzinger, F., Lang, M., Belik, S., Jilma‐Stohlawetz, P., Schmetterer, K. G., Haslacher, H., Perkmann, T., & Quehenberger, P. (2016) · Thrombosis and Haemostasis · doi:10.1160/th16-02-0081 · Cited by 54 · see citing works
Yelnik, C. M., Porter, T. F., Branch, D. W., Laskin, C. A., Merrill, J. T., Guerra, M. M., Lockshin, M. D., Buyon, J. P., Petri, M., Sammaritano, L. R., et al. (2016) · Arthritis & Rheumatology · doi:10.1002/art.39668 · Cited by 54 · see citing works
Lupus Anticoagulant Testing: Performance and Practices by North American Clinical Laboratories
Dembitzer, F. R., Ledford Kraemer, M. R., Meijer, P., & Peerschke, E. I. B. (2010) · American Journal of Clinical Pathology · doi:10.1309/ajcp4spplg5xvixf · Cited by 53 · see citing works
Favaloro, E. J. (2020) · American Journal of Hematology · doi:10.1002/ajh.25669 · Cited by 53 · see citing works
Chantarangkul, V., Tripodi, A., Arbini, A., & Mannucci, P. M. (1992) · Thrombosis Research · doi:10.1016/0049-3848(92)90266-d · Cited by 52 · see citing works
ten Boekel, E., & Bartels, P. (2002) · Pathophysiology of Haemostasis and Thrombosis · doi:10.1159/000065217 · Cited by 51 · see citing works
Misasi, R., Capozzi, A., Longo, A., Recalchi, S., Lococo, E., Alessandri, C., Conti, F., Valesini, G., & Sorice, M. (2015) · Journal of Immunology Research · doi:10.1155/2015/858542 · Cited by 51 · see citing works
Laboratory investigation of lupus anticoagulants: mixing studies are sometimes required
FAVALORO, E. J., BONAR, R., ZEBELJAN, D., KERSHAW, G., & MARSDEN, K. (2010) · Journal of Thrombosis and Haemostasis · doi:10.1111/j.1538-7836.2010.04090.x · Cited by 48 · see citing works
Cohen, H., Mackie, I. J., & Devreese, K. M. J. (2019) · Journal of Thrombosis and Haemostasis · doi:10.1111/jth.14560 · Cited by 48 · see citing works
Okuda, M., & Yamamoto, Y. (2004) · Clinical and Laboratory Haematology · doi:10.1111/j.1365-2257.2004.00605.x · Cited by 47 · see citing works
Moore, G. W., Smith, M. P., & Savidge, G. F. (2003) · Blood Coagulation & Fibrinolysis · doi:10.1097/01.mbc.0000061283.28953.39 · Cited by 47 · see citing works
Self-citationDe Kesel, P. M. M., & Devreese, K. M. J. (2020) · Research and Practice in Thrombosis and Haemostasis · doi:10.1002/rth2.12264 · Cited by 47 · see citing works
Moore, G. W., Jones, P. O., Platton, S., Hussain, N., White, D., Thomas, W., Rigano, J., Pouplard, C., Gray, E., & Devreese, K. M. J. (2021) · Journal of Thrombosis and Haemostasis · doi:10.1111/jth.15438 · Cited by 47 · see citing works
Self-citationEvaluation of Different Mixing Study Reagents and Dilution Effect in Lupus Anticoagulant Testing
Kaczor, D. A., Bickford, N. N., & Triplett, D. A. (1991) · American Journal of Clinical Pathology · doi:10.1093/ajcp/95.3.408 · Cited by 46 · see citing works
Lipid composition of seven APTT reagents in relation to heparin sensitivity
Kitchen, S., Cartwright, I. J., Woods, T. A. L., Jennings, I., & Preston, F. E. (1999) · British Journal of Haematology · doi:10.1046/j.1365-2141.1999.01596.x · Cited by 46 · see citing works
Interpretation of normal plasma mixing studies in the laboratory diagnosis of lupus anticoagulants
Devreese, K. M. J. (2007) · Thrombosis Research · doi:10.1016/j.thromres.2006.03.012 · Cited by 46 · see citing works
Moore, G. W., & Savidge, G. F. (2006) · Thrombosis Research · doi:10.1016/j.thromres.2005.09.010 · Cited by 46 · see citing works
Self-citationEffects of Direct Oral Anticoagulants on Lupus Anticoagulant Assays in a Real-Life Setting
Antovic, A., Norberg, E.-M., Berndtsson, M., Rasmuson, A., Malmström, R. E., Skeppholm, M., & Antovic, J. (2017) · Thrombosis and Haemostasis · doi:10.1160/th17-03-0204 · Cited by 46 · see citing works
Meroni, P. L., & Borghi, M. O. (2021) · Frontiers in Immunology · doi:10.3389/fimmu.2021.726820 · Cited by 46 · see citing works
Evaluation of Recently Described Tests for Detection of the Lupus Anticoagulant
Forastiero, R. R., Cerrato, G. S., & Carreras, L. O. (1994) · Thrombosis and Haemostasis · doi:10.1055/s-0038-1648949 · Cited by 43 · see citing works
Laboratory Diagnosis of Lupus Anticoagulants for Patients on Oral Anticoagulant Treatment
Chantarangkul, V., Clerici, M., Mannucci, P. M., & Tripodi, A. (2002) · Thrombosis and Haemostasis · doi:10.1055/s-0037-1613259 · Cited by 43 · see citing works
DEVREESE, K. M. J. (2010) · Journal of Thrombosis and Haemostasis · doi:10.1111/j.1538-7836.2010.03807.x · Cited by 42 · see citing works
Moore, G. W., Culhane, A. P., Daw, C. R., Noronha, C. P., & Kumano, O. (2016) · Thrombosis Research · doi:10.1016/j.thromres.2016.01.019 · Cited by 42 · see citing works
Exner, T., Ahuja, M., & Ellwood, L. (2018) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2018-0967 · Cited by 42 · see citing works
Commonalities and contrasts in recent guidelines for lupus anticoagulant detection
Moore, G. W. (2014) · International Journal of Laboratory Hematology · doi:10.1111/ijlh.12227 · Cited by 41 · see citing works
Self-citationCox‐Morton, S., MacDonald, S. G., & Thomas, W. (2019) · British Journal of Haematology · doi:10.1111/bjh.16091 · Cited by 40 · see citing works
De Kesel, P. M., & Devreese, K. M. J. (2020) · Journal of Thrombosis and Haemostasis · doi:10.1111/jth.14894 · Cited by 40 · see citing works
Misasi, R., Longo, A., Recalchi, S., Caissutti, D., Riitano, G., Manganelli, V., Garofalo, T., Sorice, M., & Capozzi, A. (2020) · International Journal of Molecular Sciences · doi:10.3390/ijms21218411 · Cited by 40 · see citing works
Normal plasma mixing studies in the laboratory diagnosis of lupus anticoagulant
Thom, J., Ivey, L., & Eikelboom, J. (2003) · Journal of Thrombosis and Haemostasis · doi:10.1111/j.1538-7836.2003.0543h.x · Cited by 39 · see citing works
Noordermeer, T., Molhoek, J. E., Schutgens, R. E. G., Sebastian, S. A. E., Drost‐Verhoef, S., van Wesel, A. C. W., de Groot, P. G., Meijers, J. C. M., & Urbanus, R. T. (2021) · Journal of Thrombosis and Haemostasis · doi:10.1111/jth.15241 · Cited by 38 · see citing works
Lupus anticoagulant: performance of the tests as recommended by the latest ISTH guidelines
Swadźba, J., Iwaniec, T., PULKA, M., de Laat, B., de Groot, P. G., & Musiał, J. (2011) · Journal of Thrombosis and Haemostasis · doi:10.1111/j.1538-7836.2011.04420.x · Cited by 36 · see citing works
Effects of Pentasaccharide (Fondaparinux) and Direct Thrombin Inhibitors on Coagulation Testing
Gosselin, R. C., King, J. H., Janatpur, K. A., et al. (2004) · Archives of Pathology & Laboratory Medicine · doi:10.5858/2004-128-1142-eopfad · Cited by 36 · see citing works
Current Controversies in Lupus Anticoagulant Detection
Moore, G. (2016) · Antibodies · doi:10.3390/antib5040022 · Cited by 36 · see citing works
Self-citationYin, D., de Groot, P. G., Ninivaggi, M., Devreese, K. M. J., & de Laat, B. (2021) · Thrombosis and Haemostasis · doi:10.1055/a-1344-4271 · Cited by 36 · see citing works
Preparation of plasma for the detection of lupus anticoagulants and antiphospholipid antibodies
Sletnes, K. E., Gravem, K., & Wislöff, F. (1992) · Thrombosis Research · doi:10.1016/0049-3848(92)90154-3 · Cited by 35 · see citing works
Tripodi, A., Chantarangkul, V., Cini, M., Devreese, K., Dlott, J. S., Giacomello, R., Gray, E., Legnani, C., Martinuzzo, M. E., Pradella, P., et al. (2017) · Journal of Thrombosis and Haemostasis · doi:10.1111/jth.13678 · Cited by 35 · see citing works
Lupus Antibody Bivalency Is Required to Enhance Prothrombin Binding to Phospholipid
Field, S. L., Chesterman, C. N., Dai, Y., et al. (2001) · The Journal of Immunology · doi:10.4049/jimmunol.166.10.6118 · Cited by 34 · see citing works
Depreter, B., & Devreese, K. M. J. (2016) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2015-0978 · Cited by 34 · see citing works
Dilute Russell's viper venom time reagents in lupus anticoagulant testing: a well‐considered choice
Depreter, B., & Devreese, K. M. J. (2017) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2016-0245 · Cited by 34 · see citing works
Transient Lupus Anticoagulants in Children: Stepwise Disappearance of Diagnostic Features
Lechner, K., Speiser, W., Pabinger, I., & Male, C. (2000) · Thrombosis and Haemostasis · doi:10.1055/s-0037-1613777 · Cited by 33 · see citing works
Comparison of six dilute Russell viper venom time lupus anticoagulant screen/confirm assay kits
Fritsma, G., & McGlasson, D. (2013) · Seminars in Thrombosis and Hemostasis · doi:10.1055/s-0033-1334865 · Cited by 33 · see citing works
Moore, G. W. (2007) · Thrombosis Journal · doi:10.1186/1477-9560-5-12 · Cited by 32 · see citing works
Self-citationQi, W., Zhao, J., Huang, C., Jiang, N., Li, J., Wu, C., Zhang, S., Hu, C., Xu, D., Wang, Q., et al. (2022) · Arthritis Research & Therapy · doi:10.1186/s13075-022-02814-w · Cited by 32 · see citing works
Optimisation of lupus anticoagulant tests: should test samples always be mixed with normal plasma?
Pennings, M., de Groot, P., Meijers, J., Huisman, A., Derksen, R., & Urbanus, R. (2014) · Thrombosis and Haemostasis · doi:10.1160/th14-02-0122 · Cited by 31 · see citing works
The Effects of Indirect- and Direct-Acting Anticoagulants on Lupus Anticoagulant Assays
Seheult, J. N., Meyer, M. P., Bontempo, F. A., & Chibisov, I. (2017) · American Journal of Clinical Pathology · doi:10.1093/ajcp/aqx035 · Cited by 31 · see citing works
Snake Venoms in Diagnostic Hemostasis and Thrombosis
Moore, G. W. (2021) · Seminars in Thrombosis and Hemostasis · doi:10.1055/s-0041-1732465 · Cited by 31 · see citing works
Self-citationLaboratory methods to detect antiphospholipid antibodies
Krilis, S. A., & Giannakopoulos, B. (2014) · Hematology · doi:10.1182/asheducation-2014.1.321 · Cited by 30 · see citing works
Baker, S. A., Jin, J., Pfaffroth, C., Vu, T., & Zehnder, J. L. (2021) · Research and Practice in Thrombosis and Haemostasis · doi:10.1002/rth2.12472 · Cited by 30 · see citing works
Testing for Lupus Anticoagulants
Moore, G. W. (2022) · Seminars in Thrombosis and Hemostasis · doi:10.1055/s-0042-1744363 · Cited by 30 · see citing works
Self-citationLupus Anticoagulants:First French Interlaboratory Etalonorme Survey
Roussi, J., Jp, R., & Goguel, A. (1996) · American Journal of Clinical Pathology · doi:10.1093/ajcp/105.6.788 · Cited by 29 · see citing works
Activated Partial Thromboplastin Time and Prothrombin Time Mixing Studies: Current State of the Art
Adcock, D. M., Moore, G. W., Montalvão, S. A. D. L., Kershaw, G. W., & Gosselin, R. C. (2022) · Seminars in Thrombosis and Hemostasis · doi:10.1055/s-0042-1756196 · Cited by 29 · see citing works
Self-citationLupus anticoagulant detection: out of control?
Moore, G. W., Brown, K. L., Bromidge, E. S., Drew, A. J., & Ledford‐Kraemer, M. R. (2013) · International Journal of Laboratory Hematology · doi:10.1111/ijlh.12006 · Cited by 27 · see citing works
Self-citationTanaka, K. A., Bharadwaj, S., Hasan, S., Judd, M., Abuelkasem, E., Henderson, R. A., Chow, J. H., Williams, B., Mazzeffi, M. A., Crimmins, S. D., et al. (2019) · British Journal of Anaesthesia · doi:10.1016/j.bja.2019.02.012 · Cited by 27 · see citing works
Kumano, O., & Moore, G. W. (2018) · Research and Practice in Thrombosis and Haemostasis · doi:10.1002/rth2.12069 · Cited by 26 · see citing works
Self-citationPradella, P., Azzarini, G., Santarossa, L., Caberlotto, L., Bardin, C., Poz, A., D’Aurizio, F., & Giacomello, R. (2013) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2012-0382 · Cited by 26 · see citing works
Liu, H. W., Wong, K., Lin, C. K., Wong, W. S., Tse, P. W. T., & Chan, G. T. C. (1989) · British Journal of Haematology · doi:10.1111/j.1365-2141.1989.tb07687.x · Cited by 26 · see citing works
Goudemand, J., Caron, C., de Prost, D., et al. (1997) · Thrombosis and Haemostasis · doi:10.1055/s-0038-1655965 · Cited by 25 · see citing works
Tests for lupus anticoagulant revisited
Derksen, R. H. W. M., & de Groot, P. G. (2004) · Thrombosis Research · doi:10.1016/j.thromres.2004.06.009 · Cited by 25 · see citing works
Moore, G. W., Culhane, A. P., Maloney, J. C., Archer, R. A., Breen, K. A., & Hunt, B. J. (2015) · Blood Coagulation & Fibrinolysis · doi:10.1097/mbc.0000000000000486 · Cited by 25 · see citing works
Self-citationHillarp, A., Strandberg, K., Baghaei, F., Fagerberg, I., Gustafsson, K. M., & Lindahl, T. L. (2018) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365513.2018.1522664 · Cited by 25 · see citing works
Quality indices in a cervicovaginal cytology service: before and after laboratory accreditation.
Tan, K., Chang, S. A., Soh, V. H., Thamboo, T., Nilsson, B., & Chan, N. (2004) · Archives of Pathology & Laboratory Medicine · doi:10.1043/1543-2165(2004)128 · Cited by 25
False negative screening tests for lupus anticoagulants—An unrecognized problem?
Jacobsen, E. M., & Wislöff, F. (1996) · Thrombosis Research · doi:10.1016/0049-3848(96)00094-1 · Cited by 24 · see citing works
Dragoni, F., Minotti, C., Palumbo, G., Faillace, F., Redi, R., Bongarzoni, V., & Avvisati, G. (2001) · Thrombosis Research · doi:10.1016/s0049-3848(00)00374-1 · Cited by 24 · see citing works
Dilute prothrombin time-based lupus ratio test
Liestøl, S., Jacobsen, E. M., & Wislöff, F. (2002) · Thrombosis Research · doi:10.1016/s0049-3848(01)00420-0 · Cited by 23 · see citing works
Genzen, J. R., & Miller, J. L. (2005) · American Journal of Clinical Pathology · doi:10.1309/7ryun5drk4wch3pm · Cited by 23 · see citing works
Hillarp, A., Strandberg, K., Gustafsson, K. M., & Lindahl, T. L. (2020) · Journal of Thrombosis and Haemostasis · doi:10.1111/jth.14829 · Cited by 23 · see citing works
A clinical study of the lupus anticoagulant
Schleider, M., Nachman, R. L., Jaffe, E., et al. (1976) · Blood · doi:10.1182/blood.v48.4.499.bloodjournal484499 · Cited by 23 · see citing works
Stevenson, K. J., & Seddon, J. M. (1994) · British Journal of Haematology · doi:10.1111/j.1365-2141.1994.tb04790.x · Cited by 22 · see citing works
Clinical significance of the mixing test in laboratory diagnoses of lupus anticoagulant
Hong, S. K., Hwang, S. M., Kim, J.-E., & Kim, H. K. (2012) · Blood Coagulation & Fibrinolysis · doi:10.1097/mbc.0b013e328358e899 · Cited by 22 · see citing works
Pengo, V., Zardo, L., Cattini, M. G., Bison, E., Pontara, E., Altinier, S., Cheng, C., & Denas, G. (2020) · TH Open · doi:10.1055/s-0040-1705091 · Cited by 22 · see citing works
Adcock, D. M., & Marlar, R. A. (1992) · PubMed · Cited by 21 · see citing works
<i>In</i> ECAT <i>veritas?</i>
Reber, G., & Meijer, P. (2012) · Lupus · doi:10.1177/0961203312446389 · Cited by 21 · see citing works
Measurement of Lupus Anticoagulants: An Update on Quality in Laboratory Testing
Adams, M. J. (2013) · Seminars in Thrombosis and Hemostasis · doi:10.1055/s-0033-1334864 · Cited by 21 · see citing works
Further evidence of false negative screening for lupus anticoagulants
Moore, G. W., Henley, A., Greenwood, C. K., & Rangarajan, S. (2007) · Thrombosis Research · doi:10.1016/j.thromres.2007.05.018 · Cited by 21 · see citing works
Self-citationBiguzzi, E., Asti, D., Palmucci, C., Tripodi, A., & Chantarangkul, V. (2013) · Thrombosis and Haemostasis · doi:10.1160/th12-11-0850 · Cited by 21 · see citing works
Improved detection of lupus anticoagulants by the dilute Russell's Viper venom time
Moore, G. W., Savidge, G. F., & Smith, M. (2000) · Blood Coagulation & Fibrinolysis · doi:10.1097/00001721-200012000-00011 · Cited by 20 · see citing works
Self-citationChandler, J. B., Torres, R., Rinder, H. M., & Tormey, C. A. (2014) · British Journal of Haematology · doi:10.1111/bjh.13030 · Cited by 20 · see citing works
Moore, G. W., Maloney, J. C., de Jager, N., Dunsmore, C. L., Gorman, D. K., Polgrean, R. F., & Bertolaccini, M. L. (2017) · Research and Practice in Thrombosis and Haemostasis · doi:10.1002/rth2.12006 · Cited by 20 · see citing works
Self-citationMixing studies for lupus anticoagulant: mostly yes, sometimes no
Favaloro, E. (2020) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2019-1240 · Cited by 20 · see citing works
Warfarin does not interfere with lupus anticoagulant detection by dilute Russell's viper venom time.
Olteanu, H., Downes, K. A., Patel, J., Praprotnik, D., & Sarode, R. (2009) · PubMed · Cited by 20 · see citing works
Moore, G. W., & Savidge, G. F. (2004) · Blood Coagulation & Fibrinolysis · doi:10.1097/00001721-200404000-00015 · Cited by 19 · see citing works
Self-citationMixing studies for lupus anticoagulant: mostly no, sometimes yes
Moore, G. W. (2020) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2019-1248 · Cited by 19 · see citing works
Self-citationMoore, G. W., & Kumano, O. (2020) · Journal of Thrombosis and Haemostasis · doi:10.1111/jth.14669 · Cited by 18 · see citing works
Self-citationAlternative assays to dRVVT and aPTT for lupus anticoagulant detection
Moore, G. W. (2020) · American Journal of Hematology · doi:10.1002/ajh.25836 · Cited by 18 · see citing works
Self-citationFactor VIII as a potential player in cancer pathophysiology
Walker, G. E., Merlin, S., Zanolini, D., Vandoni, A., Volpe, A., Gaïdano, G., Valente, G., Olivero, M., & Follenzi, A. (2021) · Journal of Thrombosis and Haemostasis · doi:10.1111/jth.15611 · Cited by 18 · see citing works
Gardiner, C., Mackie, I. J., Malía, R. G., et al. (2000) · British Journal of Haematology · doi:10.1111/j.1365-2141.2000.02466.x · Cited by 18 · see citing works
von Landenberg, P., Döring, Y., Modrow, S., & Lackner, K. J. (2007) · Annals of the New York Academy of Sciences · doi:10.1196/annals.1422.060 · Cited by 17 · see citing works
Tripodi, A., Scalambrino, E., Chantarangkul, V., Paoletti, O., Clerici, M., Novembrino, C., Boscolo-Anzoletti, M., Peyvandi, F., & Testa, S. (2021) · Thrombosis Research · doi:10.1016/j.thromres.2021.06.001 · Cited by 17 · see citing works
Screening for lupus anticoagulants in patients treated with vitamin K antagonists
Isert, M., Miesbach, W., Stoever, G., Lindhoff‐Last, E., & Linnemann, B. (2015) · International Journal of Laboratory Hematology · doi:10.1111/ijlh.12409 · Cited by 16 · see citing works
Dynamic APTT parameters: applications in thrombophilia
Sørensen, B., & Ingerslev, J. (2011) · Journal of Thrombosis and Haemostasis · doi:10.1111/j.1538-7836.2011.04600.x · Cited by 16 · see citing works
Farkh, C., Ellouze, S., Gounelle, L., Sad Houari, M., Duchemin, J., Proulle, V., Fontenay, M., Delavenne, X., & Jourdi, G. (2021) · Frontiers in Medicine · doi:10.3389/fmed.2021.683357 · Cited by 16 · see citing works
Moore, G. W., Smith, M. P., Patel, Y., & Savidge, G. F. (2002) · Blood Coagulation & Fibrinolysis · doi:10.1097/00001721-200204000-00013 · Cited by 15 · see citing works
Self-citationGay, J., Duchemin, J., Imarazene, M., Fontenay, M., & Jourdi, G. (2019) · International Journal of Laboratory Hematology · doi:10.1111/ijlh.13101 · Cited by 15 · see citing works
Kumano, O., Ieko, M., Naito, S., Yoshida, M., Takahashi, N., & Aoki, T. (2013) · Journal of Thrombosis and Haemostasis · doi:10.1111/jth.12345 · Cited by 14 · see citing works
Grypiotis, P., Ruffatti, A., Pengo, V., et al. (2006) · Journal of Clinical Laboratory Analysis · doi:10.1002/jcla.20093 · Cited by 14 · see citing works
Evaluation of a new commercial dilute prothrombin time in the diagnosis of Lupus Anticoagulants
Devreese, K. M. J. (2008) · Thrombosis Research · doi:10.1016/j.thromres.2008.04.005 · Cited by 14 · see citing works
Gerbutavičius, R., Fareed, J., Messmore, H. L., Iqbal, O., Hoppensteadt, D. A., Wehrmacher, W. H., Demir, M., Piccolo, P., Ahmad, S., Ma, Q., et al. (2002) · Clinical and Applied Thrombosis/Hemostasis · doi:10.1177/107602960200800206 · Cited by 14 · see citing works
Moore, G. W., Peyrafitte, M., Dunois-Lardé, C., & Amiral, J. (2017) · Lupus · doi:10.1177/0961203317711773 · Cited by 14 · see citing works
Self-citationImpact of different preanalytical conditions on results of lupus anticoagulant tests
Kristoffersen, A. H., Hammer, I. J., Vannes, S., Åsberg, A., & Aakre, K. M. (2019) · International Journal of Laboratory Hematology · doi:10.1111/ijlh.13102 · Cited by 14 · see citing works
Reda, S., Brügelmann, A., Müller, J., Oldenburg, J., Pötzsch, B., & Rühl, H. (2020) · Scientific Reports · doi:10.1038/s41598-020-69199-1 · Cited by 14 · see citing works
Diagnostic Challenges on the Laboratory Detection of Lupus Anticoagulant
Tripodi, A. (2021) · Biomedicines · doi:10.3390/biomedicines9070844 · Cited by 14 · see citing works
Lupus Anticoagulant Testing with Optical End Point Automation
Luddington, R. J., Scales, C., & Baglin, T. P. (1999) · Thrombosis Research · doi:10.1016/s0049-3848(99)00096-1 · Cited by 13 · see citing works
Skaugen, J. M., Sayre, C., Hassett, A. C., Chibisov, I., Bontempo, F. A., Meyer, M. P., & Seheult, J. N. (2021) · American Journal of Clinical Pathology · doi:10.1093/ajcp/aqab149 · Cited by 12 · see citing works
Variability among commercial batches of normal pooled plasma in lupus anticoagulant testing
Cabo, J., Morimont, L., Baudar, J., Guldenpfennig, M., Jacqmin, H., Soleimani, R., Lecompte, T., Douxfils, J., & Mullier, F. (2022) · International Journal of Laboratory Hematology · doi:10.1111/ijlh.13977 · Cited by 12 · see citing works
Olah, Z., Szarvas, M., Bereczky, Z., Kerenyi, A., Kappelmayer, J., & Boda, Z. (2013) · Archives of Pathology and Laboratory Medicine · doi:10.5858/arpa.2012-0236-oa · Cited by 11 · see citing works
Chandrashekar, V. (2015) · Blood Coagulation & Fibrinolysis · doi:10.1097/mbc.0000000000000463 · Cited by 11 · see citing works
A new lupus anticoagulant test based on dilute prothrombin time
Mackie, I., Lawrie, A., Greenfield, R., Guinto, E., & Machin (2004) · UCL Discovery (University College London) · Cited by 11 · see citing works
Giarretta, I., Ageno, W., & Dentali, F. (2022) · Haematologica · doi:10.3324/haematol.2022.281586 · Cited by 11 · see citing works
Murer, L. M., Pirruccello, S. J., & Koepsell, S. A. (2016) · Laboratory Medicine · doi:10.1093/labmed/lmw029 · Cited by 10 · see citing works
The effect of DOAC‐Stop® on several oral and parenteral anticoagulants
Riva, N., Vella, K., Hickey, K. P., et al. (2021) · International Journal of Laboratory Hematology · doi:10.1111/ijlh.13487 · Cited by 10 · see citing works
The Activated Seven Lupus Anticoagulant Assay Detects Clinically Significant Antibodies
Moore, G. W., Rangarajan, S., & Savidge, G. F. (2007) · Clinical and Applied Thrombosis/Hemostasis · doi:10.1177/1076029607305099 · Cited by 9 · see citing works
Self-citationAverina, M., Johannesen, S., & Brox, J. H. (2015) · Lupus · doi:10.1177/0961203315617540 · Cited by 9 · see citing works
Clinical usefulness of the dilute Russell viper venom time test for patients taking warfarin
Kanouchi, K., Narimatsu, H., OHNUMA, O., Morikane, K., & Fukao, A. (2017) · International Journal of Hematology · doi:10.1007/s12185-017-2228-y · Cited by 8 · see citing works
Moore, G. W. (2017) · Thrombosis Research · doi:10.1016/j.thromres.2017.09.017 · Cited by 8 · see citing works
Self-citationChantarangkul, V., Peyvandi, F., & Tripodi, A. (2020) · Thrombosis Research · doi:10.1016/j.thromres.2020.03.018 · Cited by 8 · see citing works
Kumano, O., Ieko, M., Naito, S., et al. (2014) · Clinical Laboratory · doi:10.7754/clin.lab.2014.140616 · Cited by 8 · see citing works
Martinuzzo, M. E., Adamczuk, Y., Varela, M. I., et al. (2005) · Thrombosis and Haemostasis · doi:10.1055/s-0037-1616577 · Cited by 7 · see citing works
Moore, G. W., KAMAT, A. V., Gurney, D. A., O’Connor, O., Rangarajan, S., Carr, R. A., & Savidge, G. F. (2004) · Clinical & Laboratory Haematology · doi:10.1111/j.1365-2257.2004.00644.x · Cited by 6 · see citing works
Self-citationTaipan snake venom time for antiphospholipid syndrome solves a 20‐year diagnostic challenge
Cunliffe, A., Dobson, J., Swallow, G., Ravenscroft, J., & Tang, T. S. (2020) · Clinical and Experimental Dermatology · doi:10.1111/ced.14229 · Cited by 6 · see citing works
Ling, L., Liu, C., Huang, X., Liao, J., Jia, J., & Zhou, J. (2022) · International Journal of Laboratory Hematology · doi:10.1111/ijlh.13830 · Cited by 5 · see citing works
Qi, W., Zhao, J., Huang, C. L., Jiang, N., Li, J., Wu, C., Zhang, S., Hu, C., Xu, D. Z., Wang, Q., et al. (2021) · Research Square · doi:10.21203/rs.3.rs-1156613/v1 · Cited by 5 · see citing works
Shimura, H., Imai, Y., Ieko, M., Shiseki, M., Mori, N., Teramura, M., & Motoji, T. (2012) · Annals of Hematology · doi:10.1007/s00277-012-1532-0 · Cited by 4 · see citing works
Antiphospholipid Antibodies in Patients With Lupus Anticoagulant Prozone Effect
Murphy, C., Jin, J., & Zehnder, J. L. (2019) · American Journal of Clinical Pathology · doi:10.1093/ajcp/aqz151 · Cited by 4 · see citing works
Asakrah, S. K., Davis, R. B., & Bhargava, P. (2021) · American Journal of Clinical Pathology · doi:10.1093/ajcp/aqab069 · Cited by 4 · see citing works
Usefulness of a Diluted Prothrombin Time for Accurately Diagnosing Antiphospholipid Syndrome
Nakai, K., Wada, H., Nakatani, K., Kamikura, Y., Mastumoto, T., Kobayashi, T., Tonomura, H., Tono, Y., Ohyabu, M., Ota, S., et al. (2009) · Vascular Disease Prevention · doi:10.2174/1567270000906010025 · Cited by 3 · see citing works
Gerbutavičius, R., Fareed, J., Messmore, H. L., et al. (2002) · Clinical and Applied Thrombosis/Hemostasis · doi:10.1177/107602960200800107 · Cited by 3 · see citing works
Usefulness of a Diluted Prothrombin Time for Accurately Diagnosing Antiphospholipid Syndrome
Nakai, K., Wada, H., Nakatani, K., et al. (2009) · Vascular Disease Prevention · doi:10.2174/1567270001006010025 · Cited by 2 · see citing works
Beyazıt, F., ÇETİN, E. Ü., & Beyazıt, Y. (2021) · Journal of the Turkish-German Gynecological Association · doi:10.4274/jtgga.galenos.2021.2021.0112 · Cited by 1 · see citing works
Flagged first, then by citations
Research works printed but not linked: 4
- Moore GW. Clinical utility of the less commonly employed assays for lupus anticoagulant detection: the evidence. J Coag Dis. 2010;2:69–79.
- Goldford MD. Lupus anticoagulant screen and confirm reagents utilizing the FX activating venom from Vipera lebetina. J Thromb Haemost. 2013;11:61.
- Jouhikainen T. Detection of lupus anticoagulant by means of dilute Russell’s viper venom time is affected by oral anticoagulant therapy. Blood Coagul Fibrinolysis. 1990;1:627–32.
- Dunois C, Peyrafitte M, De Muynck S, Villedieu V, Amiral J. New dRVVT assays for lupus anticoagulant (LA) detection with improved specificity and sensitivity: HEMOCLOT LA-S and LA-C. Res Pract Thromb Haemost. 2018;2:207.
Cited by
Sorted by citations
Kimiaei, A., Antović, J. P., & Gran, C. (2026) · Research and Practice in Thrombosis and Haemostasis · doi:10.1016/j.rpth.2026.103376
“However, both normalization methods retain uncertainties: PNP normalization is affected by manufacturer and lot variability, while reference interval normalization does not account for day-to-day analytical variation [10].”
InfluentialPerspective Chapter: Testing for Lupus Anticoagulant – Is There Light at the End of the Tunnel?
Fatmawati, K. (2026) · IntechOpen eBooks · doi:10.5772/intechopen.1014213
Androulakis, N. E. M., Nioti, E., Dilintas, A., et al. (2026) · International Journal of Laboratory Hematology · doi:10.1111/ijlh.70156
“Discordance (e.g., low factor with non-parallelism) suggests interference and should prompt qualified reporting and possible LA testing [12, 30].”
Novelli, C., Gatti, A., Ierna, F., Riccardi, E., & Cuppari, I. (2026) · International Journal of Laboratory Hematology · doi:10.1111/ijlh.70153
“In the LA testing, different diagnostic approaches can be adopted [14].”
Preliminary Evaluation of a Novel Lupus Anticoagulant Activity Assay Unaffected by Anticoagulants
Hidaka, A., Kaneshige, R., Nakamura, S., Motoki, Y., & Nojima, J. (2026) · Journal of Clinical Laboratory Analysis · doi:10.1002/jcla.70292
“In addition to DOACs, other anticoagulant therapies such as warfarin and heparin have also been reported to influence LA testing to some extent [27–31].”
- Authors
- Moore, G. W.
- Affiliations
- Cambridge University Hospitals NHS Foundation Trust (GB)
- Corresponding author
- Moore, Gary W.
- ORCID
- Moore, Gary W.
- Venue
- Exploration of Immunology
- Publisher
- Open Exploration Publishing
- Published
- 2023-08-31
- Pages
- 300-324
- ISSN
- 2768-6655 (ISSN-L)
- OpenAlex
- W4386331100
- Cited by
- 5
- References
- 169
- Citations by year
- 2026: 5
- FWCI
- 0.86
- Type
- journal article
- Language
- en
- Open access
- diamond
- doi.org
- Locations
- Exploration of Immunology (publishedVersion, cc-by)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Topics
- Health Sciences › Medicine › Rheumatology › Systemic Lupus Erythematosus Research
- Health Sciences › Medicine › Hematology › Blood Coagulation and Thrombosis Mechanisms
- Health Sciences › Medicine › Physiology › Clinical Laboratory Practices and Quality Control
- Keywords
- lupus anticoagulant, antiphospholipid syndrome, dilute Russell's viper venom time, activated partial thromboplastin time, mixing test, factor deficiency, vitamin K antagonists
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Claims read by deepseek-v4.1-flash under definition version 3 (extract-v3) on 2026-10-19.
Classified by jev-1.13-20260917 (gold-guideline-v0.2) on 2026-10-19.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review