Continuous glucose monitoring: a review of the evidence, opportunities for future use and ongoing challenges
The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
The advent of devices that can track interstitial glucose levels, which are closely related to blood glucose levels, on a near continuous basis, has facilitated better insights into patterns of glycaemia. Continuous glucose monitoring (CGM) therefore allows for more intensive monitoring of blood glucose levels and potentially improved glycaemic control. In the context of the announcement on 1 April 2017 that the Australian Government will fund CGM monitoring for people with type 1 diabetes under the age of 21 years, this paper provides a review of the evidence for CGM and some of the ongoing challenges. There is evidence that real‐time CGM in type 1 diabetes improves HbA1c and hypoglycaemia, while in type 2 diabetes, the evidence is less robust. Initial barriers to widespread implementation of CGM included issues with accuracy and user friendliness; however, as the technology has evolved, these issues have largely improved. Ongoing barriers include cost, and weaker evidence for their benefit in certain populations such as those with type 2 diabetes and less glycaemic variability. CGM has the potential to reduce healthcare costs, although real‐world studies, including cost‐effectiveness analyses, are needed in this area.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Continuous glucose monitoring and intensive treatment of type 1 diabetes
(2008) · New England Journal of Medicine · doi:10.1056/nejmoa0805017 · Cited by 1,559
Beck, R. W., Riddlesworth, T., Ruedy, K., Ahmann, A., Bergenstal, R., Haller, S., Kollman, C., Kruger, D., McGill, J. B., Polonsky, W., et al. (2017) · JAMA · doi:10.1001/jama.2016.19975 · Cited by 1,185
Effectiveness of Sensor-Augmented Insulin-Pump Therapy in Type 1 Diabetes
Bergenstal, R. M., Tamborlane, W. V., Ahmann, A., Buse, J. B., Dailey, G., Davis, S. N., Joyce, C., Peoples, T., Perkins, B. A., Welsh, J. B., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa1002853 · Cited by 894
Bolinder, J., Antuna, R., Geelhoed-Duijvestijn, P., Kröger, J., & Weitgasser, R. (2016) · The Lancet · doi:10.1016/s0140-6736(16)31535-5 · Cited by 893
Feig, D. S., Donovan, L. E., Corcoy, R., Murphy, K. E., Amiel, S. A., Hunt, K. F., Asztalos, E., Barrett, J. F. R., Sanchez, J. J., de Leiva, A., et al. (2017) · The Lancet · doi:10.1016/s0140-6736(17)32400-5 · Cited by 803
The Performance and Usability of a Factory-Calibrated Flash Glucose Monitoring System
Bailey, T., Bode, B. W., Christiansen, M. P., Klaff, L. J., & Alva, S. (2015) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2014.0378 · Cited by 685
Threshold-based insulin-pump interruption for reduction of hypoglycemia
Bergenstal, R. M., Klonoff, D. C., Garg, S. K., Bode, B. W., Meredith, M., Slover, R. H., Ahmann, A. J., Welsh, J. B., Lee, S. W., & Kaufman, F. R. (2013) · New England Journal of Medicine · doi:10.1056/nejmoa1303576 · Cited by 652
Haak, T., Hanaire, H., Ajjan, R., Hermanns, N., Riveline, J.-P., & Rayman, G. (2017) · Diabetes Therapy · doi:10.1007/s13300-016-0223-6 · Cited by 623
the SWITCH Study Group, Battelino, T., Conget, I., Olsen, B., Schütz-Fuhrmann, I., Hommel, E., Hoogma, R., Schierloh, U., Sulli, N., & Bolinder, J. (2012) · Diabetologia · doi:10.1007/s00125-012-2708-9 · Cited by 494
Murphy, H. R., Rayman, G., Lewis, K., Kelly, S., Johal, B., Duffield, K., Fowler, D., Campbell, P. J., & Temple, R. C. (2008) · BMJ · doi:10.1136/bmj.a1680 · Cited by 358
Cited by
Bolotsky, A., Butler, D., Dong, C., Gerace, K., Glavin, N. R., Muratore, C., Robinson, J. A., & Ebrahimi, A. (2019) · ACS Nano · doi:10.1021/acsnano.9b03632 · Cited by 381
Artificial Intelligence: The Future for Diabetes Care
Ellahham, S. (2020) · The American Journal of Medicine · doi:10.1016/j.amjmed.2020.03.033 · Cited by 373
Continuous glucose monitoring: A review of the evidence in type 1 and 2 diabetes mellitus
Lin, R., Brown, F., James, S., Jones, J., & Ekinci, E. (2021) · Diabetic Medicine · doi:10.1111/dme.14528 · Cited by 197
Self-citationFurler, J., O'Neal, D., Speight, J., Blackberry, I., Manski-Nankervis, J.-A., Thuraisingam, S., de La Rue, K., Ginnivan, L., Doyle, R., Holmes-Truscott, E., et al. (2020) · The Lancet Diabetes & Endocrinology · doi:10.1016/s2213-8587(19)30385-7 · Cited by 55
Self-citationValenzano, M., Cibrario Bertolotti, I., Valenzano, A., & Grassi, G. (2021) · BMJ Open Diabetes Research & Care · doi:10.1136/bmjdrc-2019-001045 · Cited by 34
Metadata
- Authors
- Wood, A., O'Neal, D., Furler, J., & Ekinci, E. I.
- Venue
- Internal Medicine Journal
- Publisher
- Wiley
- Published
- 2018-05
- Volume
- 48
- Issue
- 5
- Pages
- 499-508
- ISSN
- 1444-0903 (ISSN-L)
- 1445-5994
- OpenAlex
- W2790945825
- Cited by
- 67
- References
- 20
- FWCI
- 5.29
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.