Linear phase imaging using differential interference contrast microscopy
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Summary: We propose an extension to Nomarski differential interference contrast microscopy that enables isotropic linear phase imaging. The method combines phase shifting, two directions of shear and Fourier‐space integration using a modified spiral phase transform. We simulated the method using a phantom object with spatially varying amplitude and phase. Simulated results show good agreement between the final phase image and the object phase, and demonstrate resistance to imaging noise.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Two-Dimensional Phase Unwrapping: Theory, Algorithms, and Software
Ghiglia, D. C., & Pritt, M. D. (1998) · Medical Entomology and Zoology · Cited by 2,031
2007 IEEE International Conference on Acoustics, Speech, and Signal Processing
(2007) · 2007 IEEE International Conference on Acoustics, Speech and Signal Processing - ICASSP '07 · doi:10.1109/icassp.2007.366148 · Cited by 1,520
Larkin, K. G., Bone, D. J., & Oldfield, M. A. (2001) · Journal of the Optical Society of America A · doi:10.1364/josaa.18.001862 · Cited by 421
Self-citationQuantitative phase‐amplitude microscopy I: optical microscopy
Barone‐Nugent, E. D., Barty, A., & Nugent, K. A. (2002) · Journal of Microscopy · doi:10.1046/j.1365-2818.2002.01027.x · Cited by 190
Preza, C., Snyder, D. L., & Conchello, J.-A. (1999) · Journal of the Optical Society of America A · doi:10.1364/josaa.16.002185 · Cited by 133
The Sénarmont Compensator: An Early Application of the Geometric Phase
Hariharan, P. (1993) · Journal of Modern Optics · doi:10.1080/09500349314552081 · Cited by 23
Cited by
Spiral phase contrast imaging in microscopy
Fürhapter, S., Jesacher, A., Bernet, S., & Ritsch-Marte, M. (2005) · Optics Express · doi:10.1364/opex.13.000689 · Cited by 664
Quadriwave lateral shearing interferometry for quantitative phase microscopy of living cells
Bon, P., Maucort, G., Wattellier, B., & Monneret, S. (2009) · Optics Express · doi:10.1364/oe.17.013080 · Cited by 546
What spatial light modulators can do for optical microscopy
Maurer, C., Jesacher, A., Bernet, S., & Ritsch‐Marte, M. (2011) · Laser & Photonics Reviews · doi:10.1002/lpor.200900047 · Cited by 535
Savitzky, B. H., Zeltmann, S. E., Hughes, L. A., Brown, H. G., Zhao, S., Pelz, P. M., Pekin, T. C., Barnard, E. S., Donohue, J., Rangel DaCosta, L., et al. (2021) · Microscopy and Microanalysis · doi:10.1017/s1431927621000477 · Cited by 353
Quantitative imaging of complex samples by spiral phase contrast microscopy
Bernet, S., Jesacher, A., Fürhapter, S., Maurer, C., & Ritsch-Marte, M. (2006) · Optics Express · doi:10.1364/oe.14.003792 · Cited by 276
Metadata
- Authors
- Arnison, M. R., Larkin, K. G., Sheppard, C. J. R., Smith, N. I., & Cogswell, C. J.
- Venue
- Journal of Microscopy
- Publisher
- Wiley
- Published
- 2004-03-23
- Volume
- 214
- Issue
- 1
- Pages
- 7-12
- ISSN
- 0022-2720 (ISSN-L)
- 1365-2818
- OpenAlex
- W2150002612
- Cited by
- 271
- References
- 6
- FWCI
- 4.50
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.