Intracellular Hyperthermia for Cancer Using Magnetite Cationic Liposomes: In vitro Study
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
‘Magnetite cationic liposomes (MCL)’ were developed as a means to generate intracellular hyperthermia. Affinity of the MCL to glioma cells was ten times higher than that of magnetite‘neutral’ liposomes due to the electrostatic interaction based on the positive charge of the MCL. Heat generation of the MCL was studied using agar phantoms and small pellets of rat glioma cells. When a high‐frequency magnetic field, 118 kHz, 384 Oe was applied to glioma cells in the presence of MCL, the glioma cell pellet of 80 μl (5.4 mm in diameter) was heated to over 43°C and all the cells died after 40 min irradiation owing to the hyperthermic effect. The terminal temperature of the cell pellet was proportional to the pellet volume when other parameters were constant. It thus appears that the MCL can heat a tumor of more than 80 μl in volume to above 42°C.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Investigations on the possibility of a thermic tumour therapy—I.
Overgaard, K., & Overgaard, J. (1972) · European Journal of Cancer (1965) · doi:10.1016/0014-2964(72)90085-0 · Cited by 300
Shinkai, M., Suzuki, M., Iijima, S., & Kobayashi, T. (1995) · Biotechnology and Applied Biochemistry · doi:10.1111/j.1470-8744.1995.tb00329.x · Cited by 103
Self-citation
Cited by
Medical application of functionalized magnetic nanoparticles
Ito, A., Shinkai, M., Honda, H., & Kobayashi, T. (2005) · Journal of Bioscience and Bioengineering · doi:10.1263/jbb.100.1 · Cited by 1,470
Self-citationMagnetic fluid hyperthermia: focus on superparamagnetic iron oxide nanoparticles
Laurent, S., Dutz, S., Häfeli, U. O., & Mahmoudi, M. (2011) · Advances in Colloid and Interface Science · doi:10.1016/j.cis.2011.04.003 · Cited by 1,326
Organic Phase Syntheses of Magnetic Nanoparticles and Their Applications
Wu, L., Mendoza-Garcia, A., Li, Q., & Sun, S. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00687 · Cited by 601
Nanotechnology in hyperthermia cancer therapy: From fundamental principles to advanced applications
Beik, J., Abed, Z., Ghoreishi, F. S., Hosseini-Nami, S., Mehrzadi, S., Shakeri-Zadeh, A., & Kamrava, S. K. (2016) · Journal of Controlled Release · doi:10.1016/j.jconrel.2016.05.062 · Cited by 579
Hybrid Nanoparticles for Detection and Treatment of Cancer
Sailor, M. J., & Park, J. (2012) · Advanced Materials · doi:10.1002/adma.201200653 · Cited by 487
Metadata
- Authors
- Shinkai, M., Yanase, M., Honda, H., Wakabayashi, T., Yoshida, J., & Kobayashi, T.
- Venue
- Japanese Journal of Cancer Research
- Publisher
- Wiley
- Published
- 1996-11
- Volume
- 87
- Issue
- 11
- Pages
- 1179-1183
- ISSN
- 0910-5050 (ISSN-L)
- OpenAlex
- W4247448206
- Cited by
- 208
- References
- 2
- FWCI
- 3.65
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).