Intracellular Hyperthermia for Cancer Using Magnetite Cationic Liposomes: In vitro Study
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
‘Magnetite cationic liposomes (MCL)’ were developed as a means to generate intracellular hyperthermia. Affinity of the MCL to glioma cells was ten times higher than that of magnetite‘neutral’ liposomes due to the electrostatic interaction based on the positive charge of the MCL. Heat generation of the MCL was studied using agar phantoms and small pellets of rat glioma cells. When a high‐frequency magnetic field, 118 kHz, 384 Oe was applied to glioma cells in the presence of MCL, the glioma cell pellet of 80 μl (5.4 mm in diameter) was heated to over 43°C and all the cells died after 40 min irradiation owing to the hyperthermic effect. The terminal temperature of the cell pellet was proportional to the pellet volume when other parameters were constant. It thus appears that the MCL can heat a tumor of more than 80 μl in volume to above 42°C.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Investigations on the possibility of a thermic tumour therapy—I.
Overgaard, K., & Overgaard, J. (1972) · European Journal of Cancer (1965) · doi:10.1016/0014-2964(72)90085-0 · Cited by 300
Shinkai, M., Suzuki, M., Iijima, S., & Kobayashi, T. (1995) · Biotechnology and Applied Biochemistry · doi:10.1111/j.1470-8744.1995.tb00329.x · Cited by 103
Self-citation
Cited by
Medical application of functionalized magnetic nanoparticles
Ito, A., Shinkai, M., Honda, H., & Kobayashi, T. (2005) · Journal of Bioscience and Bioengineering · doi:10.1263/jbb.100.1 · Cited by 1,470
Self-citationMagnetic fluid hyperthermia: focus on superparamagnetic iron oxide nanoparticles
Laurent, S., Dutz, S., Häfeli, U. O., & Mahmoudi, M. (2011) · Advances in Colloid and Interface Science · doi:10.1016/j.cis.2011.04.003 · Cited by 1,326
Organic Phase Syntheses of Magnetic Nanoparticles and Their Applications
Wu, L., Mendoza-Garcia, A., Li, Q., & Sun, S. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00687 · Cited by 601
Nanotechnology in hyperthermia cancer therapy: From fundamental principles to advanced applications
Beik, J., Abed, Z., Ghoreishi, F. S., Hosseini-Nami, S., Mehrzadi, S., Shakeri-Zadeh, A., & Kamrava, S. K. (2016) · Journal of Controlled Release · doi:10.1016/j.jconrel.2016.05.062 · Cited by 579
Hybrid Nanoparticles for Detection and Treatment of Cancer
Sailor, M. J., & Park, J. (2012) · Advanced Materials · doi:10.1002/adma.201200653 · Cited by 487
Wang, S., Li, X., Chen, Y., Cai, X., Yao, H., Gao, W., Zheng, Y., An, X., Shi, J., & Chen, H. (2015) · Advanced Materials · doi:10.1002/adma.201500870 · Cited by 438
Mahmoudi, K., Bouras, A., Bozec, D., Ivkov, R., & Hadjipanayis, C. (2018) · International Journal of Hyperthermia · doi:10.1080/02656736.2018.1430867 · Cited by 414
Targeting of Cancer Cells with Ferrimagnetic Ferritin Cage Nanoparticles
Uchida, M., Flenniken, M. L., Allen, M., Willits, D. A., Crowley, B. E., Brumfield, S., Willis, A. F., Jackiw, L., Jutila, M., Young, M. J., et al. (2006) · Journal of the American Chemical Society · doi:10.1021/ja0655690 · Cited by 395
Cancer hyperthermia using magnetic nanoparticles
Kobayashi, T. (2011) · Biotechnology Journal · doi:10.1002/biot.201100045 · Cited by 354
Self-citationFunctional magnetic particles for medical application
Shinkai, M. (2002) · Journal of Bioscience and Bioengineering · doi:10.1016/s1389-1723(02)80202-x · Cited by 343
Self-citationFunctional Magnetic Particles for Medical Application.
SHINKAI, M. (2002) · Journal of Bioscience and Bioengineering · doi:10.1263/jbb.94.606 · Cited by 331
Self-citationIntracellular Hyperthermia for Cancer Using Magnetite Cationic Liposomes: An in vivo Study
Yanase, M., Shinkai, M., Honda, H., Wakabayashi, T., Yoshida, J., & Kobayashi, T. (1998) · Japanese Journal of Cancer Research · doi:10.1111/j.1349-7006.1998.tb00586.x · Cited by 322
Self-citationIto, A., Kuga, Y., Honda, H., Kikkawa, H., Horiuchi, A., Watanabe, Y., & Kobayashi, T. (2004) · Cancer Letters · doi:10.1016/j.canlet.2004.03.038 · Cited by 284
Self-citationIto, A., Honda, H., & Kobayashi, T. (2006) · Cancer Immunology, Immunotherapy · doi:10.1007/s00262-005-0049-y · Cited by 274
Self-citationWang, S., Chen, Y., Li, X., Gao, W., Zhang, L., Liu, J., Zheng, Y., Chen, H., & Shi, J. (2015) · Advanced Materials · doi:10.1002/adma.201503869 · Cited by 269
Optimizing Magnetic Nanoparticle Design for Nanothermotherapy
Gazeau, F., Lévy, M., & Wilhelm, C. (2008) · Nanomedicine · doi:10.2217/17435889.3.6.831 · Cited by 258
Controlled Release from Bilayer-Decorated Magnetoliposomes via Electromagnetic Heating
Chen, Y., Bose, A., & Bothun, G. D. (2010) · ACS Nano · doi:10.1021/nn100274v · Cited by 223
Nanoparticle Delivery Systems in Cancer Vaccines
Krishnamachari, Y., Geary, S. M., Lemke, C. D., & Salem, A. K. (2011) · Pharmaceutical Research · doi:10.1007/s11095-010-0241-4 · Cited by 219
“Magnetite nanoparticles were first described for hyperthermia cancer therapy, or “heat immunotherapy,” a little over a decade ago (170,171).”
BackgroundIto, A., Tanaka, K., Kondo, K., Shinkai, M., Honda, H., Matsumoto, K., Saida, T., & Kobayashi, T. (2003) · Cancer Science · doi:10.1111/j.1349-7006.2003.tb01438.x · Cited by 216
Self-citationIntracellular hyperthermia for cancer using magnetite cationic liposomes
Shinkai, M., Yanase, M., Suzuki, M., Honda, H., Wakabayashi, T., Yoshida, J., & Kobayashi, T. (1999) · Journal of Magnetism and Magnetic Materials · doi:10.1016/s0304-8853(98)00586-1 · Cited by 211
Self-citationReview on magnetic nanoparticle-mediated hyperthermia for cancer therapy
Rajan, A., & Sahu, N. K. (2020) · Journal of Nanoparticle Research · doi:10.1007/s11051-020-05045-9 · Cited by 204
“A number of in vivo studies on different types of cancer cells (glioblastoma, prostate, breast, melanoma, colon) have been performed corroborating MHT as a promising anti-tumoral therapy (Shinkai et al. 1996; Jordan et al. 2006; Rachakatla et al. 2010; Le Renard et al. 2010; Balivada et al. 2010).”
BackgroundFunctionalized‐Quantum‐Dot–Liposome Hybrids as Multimodal Nanoparticles for Cancer
Al‐Jamal, W. T., Al‐Jamal, K. T., Bomans, P. H., Frederik, P. M., & Kostarelos, K. (2008) · Small · doi:10.1002/smll.200701043 · Cited by 199
Ito, A., Takizawa, Y., Honda, H., Hata, K.-I., Kagami, H., Ueda, M., & Kobayashi, T. (2004) · Tissue Engineering · doi:10.1089/1076327041348301 · Cited by 197
“13 The affinity of MCLs for tumor cells is 10-fold higher than that and hepatocyte layer, using magnetic force, and whether magnetic force promotes the adhesion of heterotypic”
Self-citationIto, A., Ino, K., Kobayashi, T., & Honda, H. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2005.03.039 · Cited by 194
“When cells were cultured on the surface of neutrally charged magnetoliposomes [10], the cells floated in the media and no cells were observed to be attached to the plate (data not shown).”
BackgroundMethodSelf-citationIto, A., Ino, K., Hayashida, M., Kobayashi, T., Matsunuma, H., Kagami, H., Ueda, M., & Honda, H. (2005) · Tissue Engineering · doi:10.1089/ten.2005.11.1553 · Cited by 194
“7 8–11 With that technique, we used a magnet to cause magnetically labeled keratinocytes to accumulate on a culture surface, and created a sheetlike multilayered 3D construct without using artificial polymer scaffolds.”
Self-citationAntitumor Immunity Induction by Intracellular Hyperthermia Using Magnetite Cationic Liposomes
Yanase, M., Shinkai, M., Honda, H., Wakabayashi, T., Yoshida, J., & Kobayashi, T. (1998) · Japanese Journal of Cancer Research · doi:10.1111/j.1349-7006.1998.tb03283.x · Cited by 181
Self-citationLiposome–Nanoparticle Hybrids for Multimodal Diagnostic and Therapeutic Applications
Al-Jamal, W. T., & Kostarelos, K. (2007) · Nanomedicine · doi:10.2217/17435889.2.1.85 · Cited by 179
RGD-anchored magnetic liposomes for monocytes/neutrophils-mediated brain targeting
Jain, S., Mishra, V., Singh, P., Dubey, P. K., Saraf, D. K., & Vyas, S. P. (2003) · International Journal of Pharmaceutics · doi:10.1016/s0378-5173(03)00269-2 · Cited by 164
Ito, A., Hayashida, M., Honda, H., Hata, K.-I., Kagami, H., Ueda, M., & Kobayashi, T. (2004) · Tissue Engineering · doi:10.1089/1076327041348446 · Cited by 161
Self-citationThermosensitive liposomes entrapping iron oxide nanoparticles for controllable drug release
Tai, L.-A., Tsai, P.-J., Wang, Y.-C., Wang, Y.-J., Lo, L.-W., & Yang, C.-S. (2009) · Nanotechnology · doi:10.1088/0957-4484/20/13/135101 · Cited by 145
Metadata
- Authors
- Shinkai, M., Yanase, M., Honda, H., Wakabayashi, T., Yoshida, J., & Kobayashi, T.
- Venue
- Japanese Journal of Cancer Research
- Publisher
- Wiley
- Published
- 1996-11
- Volume
- 87
- Issue
- 11
- Pages
- 1179-1183
- ISSN
- 0910-5050 (ISSN-L)
- OpenAlex
- W4247448206
- Cited by
- 208
- References
- 2
- FWCI
- 3.65
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.