Evidence‐based strategies for preventing drug administration errors during anaesthesia
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Summary: We developed evidence‐based recommendations for the minimisation of errors in intravenous drug administration in anaesthesia from a systematic review of the literature that identified 98 relevant references (14 with experimental designs or incident reports and 19 with reports of cases or case series). We validated the recommendations using reports of drug errors collected in a previous study. One general and five specific strong recommendations were generated: systematic countermeasures should be used to decrease the number of drug administration errors in anaesthesia; the label on any drug ampoule or syringe should be read carefully before a drug is drawn up or injected; the legibility and contents of labels on ampoules and syringes should be optimised according to agreed standards; syringes should (almost) always be labelled; formal organisation of drug drawers and workspaces should be used; labels should be checked with a second person or a device before a drug is drawn up or administered.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Evidence based medicine: what it is and what it isn't
Sackett, D. L., Rosenberg, W. M. C., Gray, J. A. M., Haynes, R. B., & Richardson, W. S. (1996) · BMJ · doi:10.1136/bmj.312.7023.71 · Cited by 15,769
Normal Accidents: Living with High-Risk Technologies
Cummings, L. L., & Perrow, C. (1984) · Administrative Science Quarterly · doi:10.2307/2392945 · Cited by 2,861
Cited by
International consensus statement on the use of uterotonic agents during caesarean section
Heesen, M., Carvalho, B., Carvalho, J. C. A., Duvekot, J. J., Dyer, R. A., Lucas, D. N., McDonnell, N., Orbach‐Zinger, S., & Kinsella, S. M. (2019) · Anaesthesia · doi:10.1111/anae.14757 · Cited by 187
“Strategies that have been described to minimise the risk of drug errors include: carefully reading the ampoule label; coloured labels for the syringe; separate trays in the workspace; pre-filled syringes; and only drawing up oxytocin when it is required [97, 98].”
BackgroundAhsani-Estahbanati, E., Sergeevich Gordeev, V., & Doshmangir, L. (2022) · Frontiers in Medicine · doi:10.3389/fmed.2022.875426 · Cited by 71
Metadata
- Authors
- Jensen, L. S., Merry, A. F., Webster, C. S., Weller, J., & Larsson, L.
- Venue
- Anaesthesia
- Publisher
- Wiley
- Published
- 2004-04-16
- Volume
- 59
- Issue
- 5
- Pages
- 493-504
- ISSN
- 0003-2409 (ISSN-L)
- 1365-2044
- OpenAlex
- W2051266078
- Cited by
- 231
- References
- 2
- FWCI
- 14.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Evidence‐based strategies for preventing drug administration errors during anaesthesia. https://app.cochat.ai/papers/10.1111/j.1365-2044.2004.03670.x
- The paper
- Jensen, L. S., Merry, A. F., Webster, C. S., Weller, J., & Larsson, L. (2004). Evidence‐based strategies for preventing drug administration errors during anaesthesia. Anaesthesia. https://doi.org/10.1111/j.1365-2044.2004.03670.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.